DC5V-25V Cycle Delay Relay Module Motor Forward Reverse Start/stop Control RelayProduct features:
1. Dual power supply (two power supplies cannot be powered at the same time): Power supply 1, DC 6.5-25V; Power supply 2, DC 5V.
2. Operating current: (normal mode) standby current 41mA, operating current 83mA; (energy saving mode) standby current 7mA, operating current 44mA.
3. Three input control ports: forward control (FWD), reverse control (REV) and stop control (STOP).
3. Two input trigger modes, low pulse trigger mode and low level trigger mode.
4. Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-999 minutes.
Number of cycles: no cycle, 2-99 cycles, always cycle.
5. Three indicators: forward indicator (F LED), reverse indicator (R LED), stop indicator (S LED).
6. Relay load current, less than 5A recommended.
7. This is a multifunctional DC/AC motor forward and reverse controller with multiple control modes. Many control functions can be derived through reasonable settings.
Ports:
DC 5.5 negative: power supply 1, DC 5V supply
VIN: Power supply 2 positive, DC 6.5 - 25V supply
GND: Power supply 2 negative
FWD: Forward input control (not valid for some function modes)
REV: Reverse input control (not valid for some function modes)
STOP: stop input control (not valid for some function modes)
M+: motor positive
M-: negative terminal of motor
P+: positive terminal of the motor power supply
P-: negative terminal of the motor power supply
Product parameters:
Power supply: 5-24V DC, 5V DC
Operating current: 83mA
Standby current: 41mA
Relay load current: <5A
Delay time: 0.1-999.9sec, 1-9999sec, 1-999min
Trigger mode:
1 low pulse trigger (falling edge trigger)
2 low level triggers (rising edge trigger)
Timer:
T1: Forward timer
T2: Reverse timer
T3: Stop timer
Time units: 0.1 second, 1 second, 1 minute
Relay action:
Motor forward: relay 1 on, relay 2 off, F LED flashes.
Motor reversing: relay 1 off, relay 2 on, R LED flashes
Motor stop: relay 1 off, relay 2 off, S LED flashes.
Factory setting:
Press the \"++\" and \"--\" buttons simultaneously for 5 seconds.
Energy saving mode:
Press and hold the \"OK\" button for 5 seconds to enter the \"energy saving mode\". Press and hold the \"OK\" button again for 5 seconds to exit \"energy saving mode\". The energy saving mode simply switches off the digital tube and LED indicators, other functions are normal.
Function modes
Model F-01
When power is applied, the motor is turned forward for T1 time; then the motor is stopped for T3 time; then the motor is reversed for T2 time; so it is repeated Nx times. When the STOP port is triggered, the motor stops immediately. (Forward and reverse ports are not valid)
Type F-02
This function is a variant of F-01. F-01 operates directly after power-on, but F-02 requires the FWD or REV port to be triggered to operate.
F-11 (Trigger reversible 1)
Trigger FWD port, motor forward T1 time and stop automatically (to protect the motor, trigger REV port to stop T3 time during the delay, then reverse T2 time and trigger FWD port to retime T1).
When the REV port is triggered, the motor reverses T2 time and stops automatically (to protect the motor, during the delay, the FWD port is triggered to stop T3 time, then T1 time forward and the REV port is triggered to retime T2).
When the STOP port is triggered, the motor stops immediately, regardless of whether the motor is forward or backward.
F-12 (Trigger reversible 2)
Trigger the FWD port and the motor forward T1 time and stops automatically (during the delay period, no other port is valid except for triggering the STOP port).
When the REV port is triggered, the motor reverses T2 time and stops automatically (during the delay, no other port is valid except for triggering the STOP port).
When the STOP port is triggered, the motor stops immediately, regardless of whether the motor is moving forward or backward.
When the FWD port is at low level, the motor moves forward and stops when the FWD port is released.
When the REV port is at a low level, the motor reverses and stops when the REV port is released.
In this mode, the FWD and REV ports cannot be connected low at the same time and the STOP port is invalid.
When the FWD port is at a low level, the motor moves forward and stops when the FWD port is released.
When the REV port is at a low level, the motor reverses, and after releasing the REV port, the motor stops.
In this mode, the FWD and REV ports cannot be connected low at the same time, thus triggering the STOP port and the motor stops immediately.
Parameter settings:
There are three menus: Work menu, Function menu and Parameter menu.
Note: When entering the \"Function menu\" or \"Parameter menu\", the module is still working normally (countdown and triggers are running normally). The parameters set are only valid after power is applied again.
Product list:
Relay module*1
Shipping We will arrange shipping for you within 24 Hours after payment cleared except the holidays.
We only ship to the confirmed address provided by PayPal. Before you pay, please make sure your address in PayPal matches the address you would like us to ship to. If not, please let us know before we sent you the package, or we will not be responsible for any loss. hope you could understand.
-We ship items to Worldwide. Thank you!
-we will ship out the order in 1-2 business days after payment cleared .Since it is international shipping ,delivery time is about 15--28 business days to arrive to most countries.
Refund* We believe our items are so outstanding. We are convinced you will be happy with your Purchase.
* If you do not satisfy with our items. Please simply return to us within 30 Days in original condition. Just pay for the returned postage. Then we can issue full refund to you after the returned item arrived at our warehouse.
* Please include your ID and item number with any email requests.
response* When you satisfied with our product and services please leave us positive response.
* If you have got the package, please confirm \"Delivery on time\" For us.
* If a problem occurs, contact us immediately with any email request.
* Just contact us using the \" Ask the seller a question\" link on .
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.