Free Userbar - Userbars - User Bar - User Bars
 
Advanced search
Registered users

Username:

Password:

Log me on automatically next visit?

¬ Forgot password
¬ Registration

» Upload Userbar
» Animate Userbar
» Userbars Tutorial
» Userbar Tournaments
» Forum
» Chat Room
» FAQ
» Links

• PC Cheat Codes

>> If you dont know how to design a userbar, then write here a Userbar that you want. >> If you know how to design them help these people and design what they request.




USERBARS.org | Free Forum Userbars

On eBay now
eBay

DC5V-25V Cycle Delay Relay Module Motor Forward Reverse Start/Stop Control Relay

DC5V-25V Cycle Delay Relay Module Motor Forward Reverse Start/Stop Control Relay
$8.47

Buy Now

DC5V-25V Cycle Delay Relay Module Motor Forward Reverse start/stop Control RelayProduct Image:Product Description:

Features:
1. Dual power supply (two power supplies cannot be powered at the same time): Power supply 1, DC 6.5-25V; Power supply 2, DC 5V.
2. Working current: (Normal Mode) standby current 41mA, working current 83mA; (Energy-Saving mode) Standby current 7mA, working current 44mA.
3. There are three input control port: forward control(FWD), reverse control(REV), and stop control(STOP).
3. Two input trigger modes, Low-Pulse trigger mode, Low-Level trigger mode.
4. Delay time: 0.1-999.9 seconds, 1-9999 seconds, 1-9999 minutes.
Cycle times: no cycle, 2-99 cycles, always cycle.
5. Three indicators: forward indicator(F LED), reverse indicator(R LED), stop indicator(S LED).
6. Relay load current, recommended less than 5A.
7. This is a multi-function DC/AC motor forward and reverse controller with multiple control modes. Many control functions can be derived through reasonable settings.

Port:
DC 5.5 Female: Power supply 1, DC 5V power supply
VIN: Power 2 positive, DC 6.5-25V power supply
GND: Power supply 2 negative
FWD: Forward input control (partial Function-Mode is invalid)
REV: Reverse input control (partial Function-Mode is invalid)
STOP: Stop input control (partial Function-Mode is invalid)
M+: Motor positive
M-: Motor negative
P+: Positive terminal for motor power supply
P-: Negativeterminal for motor power supply

Specification:

Power Supply: DC 6.5-25V, DC 5V

Working Current: 83mA

Standby Current: 41mA

Relay Load Current: <5A

Delay Time: 0.1-999.9 Seconds, 1-9999 Seconds, 1-9999 Minutes

Size: 8*5cm/3.2*2in
Weight: Approx. 51g/1.8oz

Trigger Mode:

1 Low Pulse Trigger (Falling Edge Trigger)

2 Low Level Trigger (Rising Edge Trigger)

Timer:

T1: Forward Timer

T2: Reverse Timer

T3: Stop Timer

Time Unit : 0.1 Second, 1 Second, 1 Minute

Relay Action:

Motor Forward: Relay 1 is ON, relay 2 is OFF, and the F LED indicator is flashing.

Motor Reverse: Relay 1 is OFF, relay 2 is ON, and the R LED indicator is flashing..

Motor Stop: Relay 1 is OFF, relay 2 is OFF, and the S LED indicator is flashing.

Factory Settings:

Press the \"++\" and \"--\" buttons simultaneously for 5 seconds.

Energy-saving mode:

Press and hold the \"OK\" button for 5 seconds to enter the \"Energy-saving mode\". Press and hold the \"OK\" button again for 5 seconds to exit the \"Energy-saving mode\". Energy saving mode just turns off the digital tube and LED indicator, and other functions are normal.

Function mode:

F-01

After power-on, the motor is forward T1 time; then the motor stops T3 time; then the motor reverse T2 time; so it is repeated Nx times. When the STOP port is triggered, the motor stops working immediately. (FWD, REV port is invalid)

F-02

This function is a F-01 variant. F-01 is run directly after power-on, but F-02 needs to trigger FWD or REV port to run.

F-11(Trigger Reversible 1)

Trigger the FWD port, the motor is forward T1 time, and automatically stops (in order to protect the motor, during the delay period, trigger the REV port to stop T3 time and then reverse T2 time, trigger FWD port to re-time T1).

Trigger the REV port, the motor is reverse T2 time, and automatically stops (in order to protect the motor, during the delay period, the FWD port is triggered to stop the T3 time and then the T1 time is forward, and the REV port is re-timed T2).

When the STOP port is triggered, the motor stops immediately, regardless of whether the motor is forward or reverse.

F-12(Trigger Reversible 2)

Trigger the FWD port, the motor is forward T1 time and stops automatically (during the delay period, except for triggering STOP port, the other ports are invalid).

Trigger the REV port, the motor is reverses T2 time, and automatically stops (during the delay period, except for triggering STOP port, the other ports are invalid).

When the STOP port is trigger, the motor stops immediately, regardless of whether the motor is forward or reverse.

F-21

When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops.

When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops.

In this mode, the FWD and REV ports cannot be connected low level at the same time, and the STOP port is invalid.

F-22

When the FWD port is low level, the motor is forward, and after the FWD port is released, the motor stops.

When the REV port is low level, the motor is reversed, and after the REV port is released, the motor stops.

In this mode, the FWD and REV ports cannot be connected low level at the same time, triggering the STOP port, the motor stops immediately.

Parameter Setting:

There are three menus: Work Menu, Function Menu, Parameter Menu.

Note: When entering the \"Function Menu\" or \"Parameter Menu\", the module still works normally (countdown and the trigger is running normally). The set parameters are valid only after being powered on again.

1. Power on to enter the running state (Work Menu).

If the current function is F-01, then the motor direct run and the digital tube displays the countdown. F-01 is displayed after the operation is completed.

If the current function is other functions, such as F-11. Then the digital tube displays F-11. After the trigger, the digital tube displays the countdown. After the operation is completed, F-11 is displayed.

Functionmode

Digitaltubedisplay

Settingmethod

Function01

F1-01

Function02

F1-02

Function011

F1-11

Function012

F1-12

Function21

F1-21

Function22

F1-22

2. In the running state(Work Menu), short press the SET button to enter the \"Function Menu\" (Above table).

bit2

bit3-4

parameterdefinition

defaultparameter

1

-

00-99

04

2

-

00-99

00

3

-

00-99

02

4

-

00-99

00

5

-

00-99

01

6

-

00-99

00

7

-

01-03
01:0.1seconds
02:second
03:minute

timeunit

02

8

-

0-99

numberofcycles

1

9

-

01-02
01lowpulsetrigger
02lowleveltrigger

triggermode

01

Package List:

1 x Motor Controller Board

    We appreciate your response very much. As it will motivate us do better. If you have any questions with our goods or service, Please kindly contact us firstly before leaving negative response. Thank you in advance

    Warranty

    1. All merchandise will be carefully test before shipping. We will try our best to avoid any quality problem.

    2. We promise warranty for quality in one year and we will repair it free of charge. The returning shipping should be paid by customer.

    3. If you are not satisfied with the product, Please contact us. We\'ll provide you a satisfying solution.

    Shipment

    1.Normmly we will send the goods within 1-3 working days after your payment is verified .

    2.Please check if the goods are in good condition and sign before the delivery man leaves.If you find the product is lost or damaged on the way. Please take photo andlet the delivery men confirm it. Then we will help you let the shipping company compensate you.

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design