AVR EA05A Control Panel Generator Controller Automatic Voltage Regulator

AVR EA05A Control Panel Generator Controller Automatic Voltage Regulator
$33.83

Buy Now

Description:Sensing InpuuutVoltage 220 / 380 / 440 VAC, 1 phase2 wireDIP switch selectableFrequency 50 / 60 Hz, DIP switch selectablePower InputVoltage 100 ~ 300 VAC, 1 phase 2 wireOutputVoltage Max. 90 VDC @ 240 VAC inputCurrent Continuous 5AIntermittent 7A for 10 secResistance Min. 15 ohm Max. 100 ohmVoltage Regulation< ± 0.5% ( with 4% engine governing )Voltage Build-upResidual voltage at AVR terminal > 5 VACThermal Drift0.03% per °C change in AVR ambientExternal Volts Adjustmen± 7% with 1K ohm 1 watt trimmerEMI SuppressionInternal electromagnetic interference filteringUnit Power DissipationMax. 8 wattUnder Frequency Protection (Factory Setting)60 Hz system presets knee point at 55 Hz50 Hz system presets knee point at 45 HzSoft Sta...

AVR EA05A Control Panel Generator Controller Automatic Voltage Regulator

Description:
Sensing Inpuuut
Voltage 220 / 380 / 440 VAC, 1 phase2 wire
DIP switch selectable
Frequency 50 / 60 Hz, DIP switch selectable
Power Input
Voltage 100 ~ 300 VAC, 1 phase 2 wire
Output
Voltage Max. 90 VDC @ 240 VAC input
Current Continuous 5A
Intermittent 7A for 10 sec
Resistance Min. 15 ohm Max. 100 ohm
Voltage Regulation
< ± 0.5% ( with 4% engine governing )
Voltage Build-up
Residual voltage at AVR terminal > 5 VAC
Thermal Drift
0.03% per °C change in AVR ambient
External Volts Adjustmen
± 7% with 1K ohm 1 watt trimmer
EMI Suppression
Internal electromagnetic interference filtering
Unit Power Dissipation
Max. 8 watt
Under Frequency Protection (Factory Setting)
60 Hz system presets knee point at 55 Hz
50 Hz system presets knee point at 45 Hz
Soft Start Ramp Time
3 sec.
Dimensions
101mm L * 69mm W * 47.5mm H
Weight
183g ± 2%
2. Wiring
When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance.
EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”.
1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together. or connect independent.(as show as figure2).
2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC.
3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless.
P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。
C above 600V.
The EXT.VR connection wires must be made of isolated wiring.
3. Adjustments
The voltage setting for 220V/380V/440V and the
frequency setting for 50/60HZ is show in figure7.
Please check the voltage/frequency selector setting
is correct before start the generator.

Caution:
The Generator Or Avr May Be Damaged
If The Voltage / Frequency Selector
Setting Is Incorrect.
Ufro Dip:
1. Before you turn on the generator, please turn the
voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.)
2. Adjust “Stability Adjustment” clockwise slowly to
change the response time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you
just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate.
4. Field Flashing
When the regulator is operated with the generator for
the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps :
1. With the Prime-mover at rest and the regulator’s
field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in series with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.)
2. Allow approximately 3 seconds before removing
the DC source.
3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure.
4. If repeating steps a. and b. does not result in
generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator.

Package Including:
1 × Automatic Voltage Regulator Controller AVR EA05A Genset Parts
1×Product Instructions


Item SpecificsCountry of Origin United StatesBrand moto-parts-loverMPN EA05AType Automatic Voltage RegulatorModel EA05AEquipment Type Voltage RegulatorWarranty 1 YearQuantity 1 PC
Payment

Shipping

Please contact us if you have special requirements (combination of packaging etc.).

Returns Change-of-mind return can only be accepted within 8 days after purchase. All other returns can be accepted in 30days.

We will closely examine the condition of the returned items and will not issue any refund/exchange before we make sure the items are in their original neat conditions.

Contact Us

We do our best to resolve any issue. Leaving negative responses and low ratings doesn't get things solved. So please talk with us and we will not let you down.

About Us Our slogan is High Quality Parts at Best Price.Moto-parts-lover offer the Highest Quality rebuilt kit or gasket Parts for Standard and Performance use for Mni Bikes,ATV's,UTV's,Pit Bikes,Scooters and Dirt Bikes.We Pride Ourelves on Great Customer Service. We Offer Our Customers the Best Price,Highest Quality and Best Service Guaranteed.

ATV & UTV Rebuild kitATV & UTV GasketMotorcycle repair kitMotorcycle Gasket Shop CategoryStore Home Carburetor Diaphragm Carburetor Rebuild Kit Air Filter Exhaust Muffler Pipe Intake Manifold Boot Engine Gasket Kit Cylinder & Fitting Starter Motor Engine Kit Home & Garden▷Carburetor♢Lawn Mower ♢String Trimmer♢chainsaws♢Leaf blower◈Snowblower◈Leaf Blower◈String Trimmer Head Lawn Mowers ◈Carburetor◈Ignition Starter◈Transmission System◈Gaskets Kit OtherHot Item 230V Compressor Duty Electric Motor 1 Phase 3450 RPM 56HZ Frame 7/8\" Shaft 5HP USD 155.65 Carburetor 591160 For Briggs & Stratton 300E 450E 500E 550e 575e 600e 125cc USD 12.28 Hand Ascender Rock Climbing Tree Arborist Rappelling For 8~13mm Gear Rope USD 26.82 Universal 6.6 Gallon Gas Fuel Tank Secondary Generator Gauge Cap Petcock Filter USD 33.85 6 Mt Hydraulic Crimper Crimping Tool Wire Battery Cable Lug Terminal w/ 8 Dies USD 31.73 Excellent Delivery

New List Item Convertible Folding Dolly 1000Lbs 2 In 1 Aluminum Hand Truck Trolley Handcart USD 109.30 15-23 Inch Drywall Stilts Aluminum Tool Stilts Black For Painting Painter Taping USD 97.77 Industrial 8L Hydraulic Pump with Manual Valve 10000PSI Single Acting USD 240.29 New 2000W Voltage Converter Transformer Step Up/Down110V-120V / 220-240V USD 52.82 New 2000W Voltage Converter Transformer Step Up/Down110V-120V to/From 220-240V USD 52.77 AVR EA05A Control Panel Generator Controller Automatic Voltage Regulator

Description:
Sensing Inpuuut
Voltage 220 / 380 / 440 VAC, 1 phase2 wire
DIP switch selectable
Frequency 50 / 60 Hz, DIP switch selectable
Power Input
Voltage 100 ~ 300 VAC, 1 phase 2 wire
Output
Voltage Max. 90 VDC @ 240 VAC input
Current Continuous 5A
Intermittent 7A for 10 sec
Resistance Min. 15 ohm Max. 100 ohm
Voltage Regulation
< ± 0.5% ( with 4% engine governing )
Voltage Build-up
Residual voltage at AVR terminal > 5 VAC
Thermal Drift
0.03% per °C change in AVR ambient
External Volts Adjustmen
± 7% with 1K ohm 1 watt trimmer
EMI Suppression
Internal electromagnetic interference filtering
Unit Power Dissipation
Max. 8 watt
Under Frequency Protection (Factory Setting)
60 Hz system presets knee point at 55 Hz
50 Hz system presets knee point at 45 Hz
Soft Start Ramp Time
3 sec.
Dimensions
101mm L * 69mm W * 47.5mm H
Weight
183g ± 2%
2. Wiring
When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance.
EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”.
1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together. or connect independent.(as show as figure2).
2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC.
3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless.
P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。
C above 600V.
The EXT.VR connection wires must be made of isolated wiring.
3. Adjustments
The voltage setting for 220V/380V/440V and the
frequency setting for 50/60HZ is show in figure7.
Please check the voltage/frequency selector setting
is correct before start the generator.

Caution:
The Generator Or Avr May Be Damaged
If The Voltage / Frequency Selector
Setting Is Incorrect.
Ufro Dip:
1. Before you turn on the generator, please turn the
voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.)
2. Adjust “Stability Adjustment” clockwise slowly to
change the response time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you
just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate.
4. Field Flashing
When the regulator is operated with the generator for
the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps :
1. With the Prime-mover at rest and the regulator’s
field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in series with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.)
2. Allow approximately 3 seconds before removing
the DC source.
3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure.
4. If repeating steps a. and b. does not result in
generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator.

Package Including:
1 × Automatic Voltage Regulator Controller AVR EA05A Genset Parts
1×Product Instructions



PaymentShippingReturnsContact UsAbout Us

Please contact us if you have special requirements (combination of packaging etc.).

Change-of-mind return can only be accepted within 8 days after purchase. All other returns can be accepted in 30days.

We will closely examine the condition of the returned items and will not issue any refund/exchange before we make sure the items are in their original neat conditions.

We do our best to resolve any issue. Leaving negative responses and low ratings doesn't get things solved. So please talk with us and we will not let you down.

Our slogan is High Quality Parts at Best Price.Moto-parts-lover offer the Highest Quality rebuilt kit or gasket Parts for Standard and Performance use for Mni Bikes,ATV's,UTV's,Pit Bikes,Scooters and Dirt Bikes.We Pride Ourelves on Great Customer Service. We Offer Our Customers the Best Price,Highest Quality and Best Service Guaranteed.

All rights reserved.


On Oct 21, 2026 at 18:58:11 PDT, seller added the following information:

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design