Free Userbar - Userbars - User Bar - User Bars
 
Advanced search
Registered users

Username:

Password:

Log me on automatically next visit?

¬ Forgot password
¬ Registration

» Upload Userbar
» Animate Userbar
» Userbars Tutorial
» Userbar Tournaments
» Forum
» Chat Room
» FAQ
» Links

• PC Cheat Codes

>> If you dont know how to design a userbar, then write here a Userbar that you want. >> If you know how to design them help these people and design what they request.




USERBARS.org | Free Forum Userbars

On eBay now
eBay

AVR EA05A Control Panel Generator Controller Automatic Voltage Regulator

AVR EA05A Control Panel Generator Controller Automatic Voltage Regulator
$34.18

Buy Now

Description:Sensing InpuuutVoltage 220 / 380 / 440 VAC, 1 phase2 wireDIP switch selectableFrequency 50 / 60 Hz, DIP switch selectablePower InputVoltage 100 ~ 300 VAC, 1 phase 2 wireOutputVoltage Max. 90 VDC @ 240 VAC inputCurrent Continuous 5AIntermittent 7A for 10 secResistance Min. 15 ohm Max. 100 ohmVoltage Regulation< ± 0.5% ( with 4% engine governing )Voltage Build-upResidual voltage at AVR terminal > 5 VACThermal Drift0.03% per °C change in AVR ambientExternal Volts Adjustmen± 7% with 1K ohm 1 watt trimmerEMI SuppressionInternal electromagnetic interference filteringUnit Power DissipationMax. 8 wattUnder Frequency Protection (Factory Setting)60 Hz system presets knee point at 55 Hz50 Hz system presets knee point at 45 HzSoft Sta...

AVR EA05A Control Panel Generator Controller Automatic Voltage Regulator

Description:
Sensing Inpuuut
Voltage 220 / 380 / 440 VAC, 1 phase2 wire
DIP switch selectable
Frequency 50 / 60 Hz, DIP switch selectable
Power Input
Voltage 100 ~ 300 VAC, 1 phase 2 wire
Output
Voltage Max. 90 VDC @ 240 VAC input
Current Continuous 5A
Intermittent 7A for 10 sec
Resistance Min. 15 ohm Max. 100 ohm
Voltage Regulation
< ± 0.5% ( with 4% engine governing )
Voltage Build-up
Residual voltage at AVR terminal > 5 VAC
Thermal Drift
0.03% per °C change in AVR ambient
External Volts Adjustmen
± 7% with 1K ohm 1 watt trimmer
EMI Suppression
Internal electromagnetic interference filtering
Unit Power Dissipation
Max. 8 watt
Under Frequency Protection (Factory Setting)
60 Hz system presets knee point at 55 Hz
50 Hz system presets knee point at 45 Hz
Soft Start Ramp Time
3 sec.
Dimensions
101mm L * 69mm W * 47.5mm H
Weight
183g ± 2%
2. Wiring
When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance.
EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”.
1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together. or connect independent.(as show as figure2).
2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC.
3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless.
P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。
C above 600V.
The EXT.VR connection wires must be made of isolated wiring.
3. Adjustments
The voltage setting for 220V/380V/440V and the
frequency setting for 50/60HZ is show in figure7.
Please check the voltage/frequency selector setting
is correct before start the generator.

Caution:
The Generator Or Avr May Be Damaged
If The Voltage / Frequency Selector
Setting Is Incorrect.
Ufro Dip:
1. Before you turn on the generator, please turn the
voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.)
2. Adjust “Stability Adjustment” clockwise slowly to
change the response time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you
just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate.
4. Field Flashing
When the regulator is operated with the generator for
the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps :
1. With the Prime-mover at rest and the regulator’s
field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in series with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.)
2. Allow approximately 3 seconds before removing
the DC source.
3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure.
4. If repeating steps a. and b. does not result in
generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator.

Package Including:
1 × Automatic Voltage Regulator Controller AVR EA05A Genset Parts
1×Product Instructions


Item SpecificsCountry of Origin United StatesBrand waltyoturMPN EA05AType Automatic Voltage RegulatorQuantity 1 PCModel EA05AManufacturer Warranty 6 monthsEquipment Type Voltage Regulator
Payment

Shipping will be arranged within 3 business day once payment is cleared.

Shipping

1.Usually your Items will be shipped within 1-3 business day after your payment is cleared.
International orders may take 10 to 30 business days to arrive.
2.We have CA, NJ warehouses and ship items may vary according to the stock.
3.No shipping on Weekends or US Public Holidays.

Returns

1.You can return your unused items back for exchange or refund within 30 days.
2.If you decide to return the item, we will provide the return address and instructions;
3.After the return is sent out, please keep the logistics tracking number to facilitate tracking.

Contact Us

1.We do our best to resolve any issue. Leaving negative responses and low ratings doesn't get things solved.

2.If there is any fault or problem with the product, we will solve it at the first time.

The Store

This is waltyotur. Our shop is mainly engaged in two major products: garden outdoor and industrial supplies. The garden outdoor products mainly include lawn mower accessories (carburetor, repair kit, lubrication system, igniter coil, seat, spindle) and anti-grass cloth, knitting rope, seedling cup and gallon basin. Industrial supplies mainly include lathe processing, hand tools, industrial consumables, industrial control systems and decoration supplies. Our store products are affordable, quality assurance, is a good choice for shopping

Home & GardenBusiness & IndustrialCommercial Machinery Shop CategoryStore Home String Trimmer◈Carburetor◈String Trimmer Head◈Repair kits Leaf Blower◈Carburetor◈Leaf Blower Parts Snow Blower◈Carburetor◈Snow Blower Parts Chain Saw◈Carburetor◈Cylinder block suite◈Recoil starter◈Repair kits◈Other Garden Tools◈Courtyard Garden Facilities◈Water Pipe◈Grass Repellent Cloth◈Braided Rope◈Nursery Cup◈Extension ladder◈Gallon Basin Outdoor Sports Other Tool Home & Garden▷Lawn mowers♢Carburetor♢Air filter♢Oil filter♢Ignition coil♢Repair kits♢Fuel valve♢Recoil starter♢Oil pump♢Oil can♢Transmission system♢Cylinder block suite♢other OtherHot Item Set of 5 3 inch Office Chair Replacement Casters Heavy Duty Rubber Swivel Wheels USD 19.58 Fits For Honda Carburetor Replace GX390 13HP GX340 11HP GX340 Generator Engine USD 17.61 Spindle Assembly 532187292 587819701 285-585 For Husqvarna 42\" 46\" 48\" 54\" Decks USD 18.78 1/2 inch 12V DC Brass Electric Solenoid Valve NPT Gas Water Air Normally Closed USD 24.43 Plastic Plant Flower Pots Nursery Seedlings Pot Planting Container 100 Pack USD 14.69 Picture

New List Item 6 Pack Lawn Mower Air Filter GY21435 For 796031 591334 594201 MIU13038 MIU14395 USD 27.00 10 Pcs Airless Paint Spray Gun 3600PSI W/517 Tip & Tip Guard For Paint Sprayers USD 168.97 2-Pack Air Filter Kit For John Deere 670P X595 X740 X750 X940 M113621 11013-1290 USD 20.00 K478 For Gast Rotary Vane Kit 0523/0323 AT03/AT05 Septic Air Pump Repair Kit USD 90.00 15\" - 23\" Adjustable Height Stilts Aluminum Drywall Tool For Painter Taping USD 99.20 Help & InfoPayment PolicyShipping PolicyReturn PolicyFAQAbout Us AVR EA05A Control Panel Generator Controller Automatic Voltage Regulator

Description:
Sensing Inpuuut
Voltage 220 / 380 / 440 VAC, 1 phase2 wire
DIP switch selectable
Frequency 50 / 60 Hz, DIP switch selectable
Power Input
Voltage 100 ~ 300 VAC, 1 phase 2 wire
Output
Voltage Max. 90 VDC @ 240 VAC input
Current Continuous 5A
Intermittent 7A for 10 sec
Resistance Min. 15 ohm Max. 100 ohm
Voltage Regulation
< ± 0.5% ( with 4% engine governing )
Voltage Build-up
Residual voltage at AVR terminal > 5 VAC
Thermal Drift
0.03% per °C change in AVR ambient
External Volts Adjustmen
± 7% with 1K ohm 1 watt trimmer
EMI Suppression
Internal electromagnetic interference filtering
Unit Power Dissipation
Max. 8 watt
Under Frequency Protection (Factory Setting)
60 Hz system presets knee point at 55 Hz
50 Hz system presets knee point at 45 Hz
Soft Start Ramp Time
3 sec.
Dimensions
101mm L * 69mm W * 47.5mm H
Weight
183g ± 2%
2. Wiring
When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance.
EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”.
1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together. or connect independent.(as show as figure2).
2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC.
3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless.
P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。
C above 600V.
The EXT.VR connection wires must be made of isolated wiring.
3. Adjustments
The voltage setting for 220V/380V/440V and the
frequency setting for 50/60HZ is show in figure7.
Please check the voltage/frequency selector setting
is correct before start the generator.

Caution:
The Generator Or Avr May Be Damaged
If The Voltage / Frequency Selector
Setting Is Incorrect.
Ufro Dip:
1. Before you turn on the generator, please turn the
voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.)
2. Adjust “Stability Adjustment” clockwise slowly to
change the response time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you
just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate.
4. Field Flashing
When the regulator is operated with the generator for
the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps :
1. With the Prime-mover at rest and the regulator’s
field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in series with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.)
2. Allow approximately 3 seconds before removing
the DC source.
3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure.
4. If repeating steps a. and b. does not result in
generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator.

Package Including:
1 × Automatic Voltage Regulator Controller AVR EA05A Genset Parts
1×Product Instructions

Item SpecificsCountry of Origin :United StatesBrand :waltyoturMPN :EA05AType :Automatic Voltage RegulatorQuantity :1 PCModel :EA05AManufacturer Warranty :6 monthsEquipment Type :Voltage Regulator

PaymentShippingReturnsContact UsThe Store

Shipping will be arranged within 3 business day once payment is cleared.

1.Usually your Items will be shipped within 1-3 business day after your payment is cleared.
International orders may take 10 to 30 business days to arrive.
2.We have CA, NJ warehouses and ship items may vary according to the stock.
3.No shipping on Weekends or US Public Holidays.

1.You can return your unused items back for exchange or refund within 30 days.
2.If you decide to return the item, we will provide the return address and instructions;
3.After the return is sent out, please keep the logistics tracking number to facilitate tracking.

1.We do our best to resolve any issue. Leaving negative responses and low ratings doesn't get things solved.

2.If there is any fault or problem with the product, we will solve it at the first time.

This is waltyotur. Our shop is mainly engaged in two major products: garden outdoor and industrial supplies. The garden outdoor products mainly include lawn mower accessories (carburetor, repair kit, lubrication system, igniter coil, seat, spindle) and anti-grass cloth, knitting rope, seedling cup and gallon basin. Industrial supplies mainly include lathe processing, hand tools, industrial consumables, industrial control systems and decoration supplies. Our store products are affordable, quality assurance, is a good choice for shopping


All rights reserved.


On Oct 21, 2026 at 18:58:03 PDT, seller added the following information:

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design