Free Userbar - Userbars - User Bar - User Bars
 
Advanced search
Registered users

Username:

Password:

Log me on automatically next visit?

¬ Forgot password
¬ Registration

» Upload Userbar
» Animate Userbar
» Userbars Tutorial
» Userbar Tournaments
» Forum
» Chat Room
» FAQ
» Links

• PC Cheat Codes

>> If you dont know how to design a userbar, then write here a Userbar that you want. >> If you know how to design them help these people and design what they request.




USERBARS.org | Free Forum Userbars

On eBay now
eBay

1PC AVR EA05A Fit For Generator Genset Automatic Voltage Regulator Controller

1PC AVR EA05A Fit For Generator Genset Automatic Voltage Regulator Controller
$33.97

Buy Now

  • Description:
  • 1PC AVR EA05A Fit For Generator Genset Automatic Voltage Regulator Controller

    Description:

    • Sensing Inpuuut
    • Voltage 220 / 380 / 440 VAC, 1 phase2 wire
    • DIP switch selectable
    • Frequency 50 / 60 Hz, DIP switch selectable
    • Power Input
    • Voltage 100 ~ 300 VAC, 1 phase 2 wire
    • Output
    • Voltage Max. 90 VDC @ 240 VAC input
    • Current Continuous 5A
    • Intermittent 7A for 10 sec
    • Resistance Min. 15 ohm Max. 100 ohm
    • Voltage Regulation
    • < ± 0.5% ( with 4% engine governing )
    • Voltage Build-up
    • Residual voltage at AVR terminal > 5 VAC
    • Thermal Drift
    • 0.03% per °C change in AVR ambient
    • External Volts Adjustmen
    • ± 7% with 1K ohm 1 watt trimmer
    • EMI Suppression
    • Internal electromagnetic interference filtering
    • Unit Power Dissipation
    • Max. 8 watt
    • Under Frequency Protection (Factory Setting)
    • 60 Hz system presets knee point at 55 Hz
    • 50 Hz system presets knee point at 45 Hz
    • Soft Start Ramp Time
    • 3 sec.
    • Dimensions
    • 101mm L * 69mm W * 47.5mm H
    • Weight
    • 183g ± 2%
    • 2. WIRING
    • When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance.
    • EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”.
    • 1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together (as show as figure3. It’s the original setting).or connect independent.(as show as figure2).
    • 2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC.
    • 3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless.
    • P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。
    • C above 600V.
    • The EXT.VR connection wires must be made of isolated wiring.
    • 3. ADJUSTMENTS
    • The voltage setting for 220V/380V/440V and the
    • frequency setting for 50/60HZ is show in figure7.
    • Please check the voltage/frequency selector setting
    • is correct before start the generator.
    • High performance,reliable quality
    • We work with every effort to provide quality products and professional service.

    CAUTION :

    • THE GENERATOR OR AVR MAY BE DAMAGED
    • IF THE VOLTAGE / FREQUENCY SELECTOR
    • SETTING IS INCORRECT.
    • UFRO DIP:
    • Close - please refer to solid curre in Figure8.
    • Open - please refer to dotted curre in Figure8.
    • 1. Before you turn on the generator, please turn the
    • voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.)
    • 2. Adjust “Stability Adjustment” clockwise slowly to
    • change the response time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you
    • just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate.
    • 4. FIELD FLASHING
    • When the regulator is operated with the generator for
    • the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps :
    • 1. With the Prime-mover at rest and the regulator’s
    • field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in series with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.)
    • 2. Allow approximately 3 seconds before removing
    • the DC source.
    • 3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure.
    • 4. If repeating steps a. and b. does not result in
    • generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator.

    About Delivery:

    • We have warehouses in California and New Jersey
    • We will follow the principle of nearest delivery
    • When one warehouse is out of stock, it will be shipped from another warehouse
    • Thank you for your Product List:

      • 1 × Automatic Voltage Regulator Controller AVR EA05A Genset Parts
      • 1 × product Instructions

      Item SpecificsCountry of Origin United StatesBrand marddpairMPN AMZ232329Equipment Type Voltage RegulatorModel EA05AWarranty 1 Year
      About us

      *. it is preferable that you email us. We will try to answer most emails within 3 days.E043

      Shipping

      *. We will delivery the package within 3 business day after your payment is cleared by PayPal.

      *. We Ship from USA stock! Fast shipping!

      Payment

      *. We accept Paypal ,Google pay, Visa,Master Card, American Express, Discover. Mastercard etc.

      *. After sale closing,pay as soon as possible.

      Contact Us
      • *. We are open Monday to Friday 8am to 5:30pm Pacific Standard Time, and Saturday 8am to12noon . Our friendly staff are available during these hours. Please feel free send us a message via .
      Terms of sales

      *. All the items are double checked before shipment, if the item is defect when you recieve it, please contact us for help, we will respond you within 24 hours and resolve your issue asap.

      *. If you are not satisfied with the transaction, please contact us . we'll do our best to solve your problems.

      *. If you are satisfied with your purchase and services, please give us a positive assessment and comprehensive assessment, the four to five stars.

      Hand ToolsEdge finderCollet ChuckTool Post 1PC AVR EA05A Fit For Generator Genset Automatic Voltage Regulator Controller

      Description:

      • Sensing Inpuuut
      • Voltage 220 / 380 / 440 VAC, 1 phase2 wire
      • DIP switch selectable
      • Frequency 50 / 60 Hz, DIP switch selectable
      • Power Input
      • Voltage 100 ~ 300 VAC, 1 phase 2 wire
      • Output
      • Voltage Max. 90 VDC @ 240 VAC input
      • Current Continuous 5A
      • Intermittent 7A for 10 sec
      • Resistance Min. 15 ohm Max. 100 ohm
      • Voltage Regulation
      • < ± 0.5% ( with 4% engine governing )
      • Voltage Build-up
      • Residual voltage at AVR terminal > 5 VAC
      • Thermal Drift
      • 0.03% per °C change in AVR ambient
      • External Volts Adjustmen
      • ± 7% with 1K ohm 1 watt trimmer
      • EMI Suppression
      • Internal electromagnetic interference filtering
      • Unit Power Dissipation
      • Max. 8 watt
      • Under Frequency Protection (Factory Setting)
      • 60 Hz system presets knee point at 55 Hz
      • 50 Hz system presets knee point at 45 Hz
      • Soft Start Ramp Time
      • 3 sec.
      • Dimensions
      • 101mm L * 69mm W * 47.5mm H
      • Weight
      • 183g ± 2%
      • 2. WIRING
      • When generator supply is over load, N phase will be different with the sharing load by 3 phases (load imbalance). Hence, the voltage from N phase to 3 phases (R.S.T.) will be altered. When the rated voltage of the traditional single input’s AVR is above 220V, it will increase the voltage drift rate by using N phase as the detective input. It will also cause the voltage imbalance.
      • EA05A can improve the above situation, and increase the generator’s rated voltage usage space,such as 380V, 440V. We can all detect by the “phase voltage”.
      • 1. When the rated phase voltage of the generator is 220VAC, the input terminals B, C and sensing terminals A, C can join together (as show as figure3. It’s the original setting).or connect independent.(as show as figure2).
      • 2. When the rated phase voltage of the generator is 380V, 440V, the input terminals B, C and sensing terminals A, C must separate connect the wiring (as show as Figure 4 or figure 5). The voltage between B and C must not be over 300 VAC.
      • 3. F+ F- terminals connect to the generator field. (J and K) FEXT.VR is the potentiometer (1KΩ 1W). These two terminals must be by-pass when external potentiometer is needless.
      • P.S. : A, B, C, F+ F- the usage of wire gauge are AWG16 or 1.25 mm2 85。
      • C above 600V.
      • The EXT.VR connection wires must be made of isolated wiring.
      • 3. ADJUSTMENTS
      • The voltage setting for 220V/380V/440V and the
      • frequency setting for 50/60HZ is show in figure7.
      • Please check the voltage/frequency selector setting
      • is correct before start the generator.
      • High performance,reliable quality
      • We work with every effort to provide quality products and professional service.

      CAUTION :

      • THE GENERATOR OR AVR MAY BE DAMAGED
      • IF THE VOLTAGE / FREQUENCY SELECTOR
      • SETTING IS INCORRECT.
      • UFRO DIP:
      • Close - please refer to solid curre in Figure8.
      • Open - please refer to dotted curre in Figure8.
      • 1. Before you turn on the generator, please turn the
      • voltage adjustment and stability adjustment full anti-clockwise. After the generator is on and run stably, turn the voltage adjustment clockwise to reach the required out voltage. (If there is an external potentiometer, turn the external potentiometer to the middle position before adjust internal voltage potentiometer.)
      • 2. Adjust “Stability Adjustment” clockwise slowly to
      • change the response time between AVR and the generator. If the adjustment is too big, it might cause the voltage instable. If too small, the load voltage will change too much at heavy load. Our suggestion is to trace by the multi-meter DCV. To adjust “stability adjustment”, you
      • just need to make the multi-meter waving smaller. It can also improve the full load’s voltage drift rate.
      • 4. FIELD FLASHING
      • When the regulator is operated with the generator for
      • the first time, the polarity of residual magnetism may be reversed or too small to achieve the necessary build-up voltage for the regulator. If reversing the field connections does not induce build-up, and the residual voltage is less than the specified value of 5 Vac, shut down the Prime-mover and proceed with the following steps :
      • 1. With the Prime-mover at rest and the regulator’s
      • field output wires disconnected, apply a DC source ( NOT grounded ) of not more than 3~12 Vdc with Positive to F+ and Negative to F-, in series with a current-limiting resistor of 3~5 ohms 20 watt. (The set battery is a suitable source.)
      • 2. Allow approximately 3 seconds before removing
      • the DC source.
      • 3. With the voltage regulator disconnected ( wires 3 and 4 ), start the prime mover and measure the “ residual ” voltage available at the auxiliary winding. If this voltage is greater than 5 Vac, reconnect voltage regulator, and voltage build-up should be successful. If less than 5 Vac is measured, repeat field flashing procedure.
      • 4. If repeating steps a. and b. does not result in
      • generator voltage build-up, and residual is greater than 5 Vac, replace voltage regulator.

      About Delivery:

      • We have warehouses in California and New Jersey
      • We will follow the principle of nearest delivery
      • When one warehouse is out of stock, it will be shipped from another warehouse
      • Thank you for your Product List:

        • 1 × Automatic Voltage Regulator Controller AVR EA05A Genset Parts
        • 1 × product Instructions


        About usShippingPaymentContact UsTerms of sales

        *. it is preferable that you email us. We will try to answer most emails within 3 days.E043

        *. We will delivery the package within 3 business day after your payment is cleared by PayPal.

        *. We Ship from USA stock! Fast shipping!

        *. We accept Paypal ,Google pay, Visa,Master Card, American Express, Discover. Mastercard etc.

        *. After sale closing,pay as soon as possible.

        • *. We are open Monday to Friday 8am to 5:30pm Pacific Standard Time, and Saturday 8am to12noon . Our friendly staff are available during these hours. Please feel free send us a message via .

        *. All the items are double checked before shipment, if the item is defect when you recieve it, please contact us for help, we will respond you within 24 hours and resolve your issue asap.

        *. If you are not satisfied with the transaction, please contact us . we'll do our best to solve your problems.

        *. If you are satisfied with your purchase and services, please give us a positive assessment and comprehensive assessment, the four to five stars.


        All rights reserved.


        On Nov 9, 2026 at 07:06:42 PST, seller added the following information:

    Buy Now

    When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


    Related Userbars
           

    More items on eBay

    As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



    All userbars are property of respective authors.
    Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design