Woodpecker ECOM Cordless Endomotor with Automatic Reverse Function
DESCRIPTION:
Woodpecker Endo Gold Endomotoris mainly used in Endodontic treatment.During root canal preparation procedure,it is used to mold & clean the root canal.
ADVANTAGES:
OLED display
a) Customized program sequencenumber 1-9, totally 9 programs
b) Operation mode
c) Battery consumption
d) Set speed
e) Set torque
f) File system
g) Operation mode
h) Torque setting
i) Real-time torque
Protective function of automatic reverse
During operation, if the load value exceeds the preset torque value, thefile rotation mode will automatically change to Reverse Mode. And thefile would return to normal rotation mode when the load is below thepreset torque value again.
a) Clockwise rotation:Load value is lower than preset torque value
b)Counterclockwise rotation:Load value is higher than preset torque value.
c)Clockwise rotation:Load value is lower than preset torque value again.
INDICATION:
- The device is suitable for shaping the root canals during root canal treatment & an advantage in replacing the hand files to rotary endodontics.
CONTRAINDICATION:
- Patients with implanted pacemakers (or other electrical equipment).
FEATURES:
- Adopt real-time response technology and dynamic torque control,effectively preventing needle breakage.
- Storage of 9 user-defined modes allows invocation at any time.Under each mode, Continuous Rotation Mode, Reciprocating MotionMode, and Reverse Rotation are for options.
KEY SPECIFICATIONS:
TECHNICAL SPECIFICATIONS:
BatteryLithium battery in handpiece: 3.7V /1400mAh
Power adapter
Input: ~100V-240V 50Hz/60Hz 0.4A MaxOutput: DC5V/1ATorque0.6Ncm-5.0Ncm(6mNm ~ 50mNm)Rotate speed100rpm~1000rpmEnvironment temperature+5°C ~ +40°CRelative humidity30% ~ 75%Atmospheric pressure70kPa ~ 106kPa
Storage:
- This equipment should be stored in a room where the relativehumidity is 10% ~ 93%, atmospheric pressure is 70kPa to106kPa, andthe temperature is -20°C ~ +55°C.
- Avoid the storage in a too hot condition. High temperature willshorten the life of electronic components, damage battery, reshape or melt some plastic.
- Avoid the storage in a too cold condition. Otherwise, when the
temperature of the equipment increases to a normal level, there will bedew that will possibly damage PCB board.
Oiling of contra-angle:
Only the original oil injection nozzle can be used for oiling of contra-angle. After disinfection of contra-angle and before sterilization, oilingshould be conducted under high pressure and high temperature.
- screw the injecting nozzle into jet of oil bottle. (Around 10
circles) - Plug the nozzle into the end part of contra-angle, and then
grease the contra-angle for 2-3s till the oil flow out of contra-angle head
part. - Vertically place the end part of contra-angle or tilt the contra-angle to
let go the redundant oil under gravity.
PACKAGING:
- 1 x Endomotor Handpiece
- 1 x Charging Base
- 1 x Contra-angle
- 1 x Power Adapter
- 1 x Lubricator
- Instructional Manual
Images are for Illustration Purpose Only
- Please Give us Positive response for Our Services .Thankyou for Buying with us . Have a nice day .
Disclaimer
\"The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not offer on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorizedpurchaser of this item before shipping of the item.\"
Business Name : Sharma & Brothers.City: JalandharState: PunjabMob:8968382891
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.