Vital Signs Monitor 14 inch Screen Multi-parameter Medical Patient Monitor
$499.00

TECHNICAL SPECIFICATIONS Quality Standards and Classification - Anti-electroshock degree:
Class I equipment [Internal power supply] TEMP/SpO₂/NIBP: BF ECG/Resp: CF
Application Range Display - 14.0-inch TFT LCD screen
Resolution: 1366×768
Environment Working Environment Conditions - Shipping and Storage Conditions
- Electrical Specifications
- Power supply voltage:AC 100–240V, 50/60Hz
- Maximum input power:70VA
- Fuse:F2AL 250V
- Working method:Continuous operation
- Built-in lithium battery:DC 11.1V, ≥2000mAh; working time ≥2 hours
Dimensions and Weight - Product size:336×262×99 mm
- Product weight:2.6 kg
ECG - Gain:×0.25, ×0.5, ×1, ×2, Auto
- Waveform speed:12.5 mm/s, 25 mm/s, 50 mm/s
- Sensitivity:>200 μV (peak-to-peak)
- Bandwidth:
- Diagnostic mode: 0.05–130 Hz
- Monitoring mode: 0.5–40 Hz
- Operation mode: 1–20 Hz
- Common Mode Rejection Ratio (CMRR):
- Diagnostic mode: >90 dB
- Monitoring mode: >100 dB
- Operation mode: >100 dB
- Electrode polarization voltage:±300 mV
- Input impedance:≥5 MΩ
- DC bias voltage:±300 mV
- Calibration signal:1 mV (peak-to-peak), accuracy ±5%
- ST segment detection:
- Measurement range: -2.0 mV to +2.0 mV
- Accuracy: ±0.02 mV or ±10% (whichever is greater) within -0.8 mV to +0.8 mV
Trend Data Length - Alarm limit list:400 groups
- Waveform playback:6000 seconds
- Trend table:7 days
- Trend graph:Up to 7 days
- Alarm review:60 groups
ST Segment - Maximum upper limit:+2.0 mV
- Minimum lower limit:-2.0 mV
- Adjustment increment:0.1 mV
NIBP (Non-Invasive Blood Pressure) - Measuring range and precision:
- Adult:
- Systolic: 40–270 mmHg
- Diastolic: 10–215 mmHg
- Mean: 20–235 mmHg
- Static pressure range:0–300 mmHg
- Static pressure precision:±3 mmHg
- Dynamic pressure precision:
- Max. average error: ±5 mmHg
- Max. standard deviation: 8 mmHg
SpO₂ - Measuring range:0–100%
- Accuracy:
- ±2% (70–100%)
- Undefined (0–69%)
Pulse Rate - Range:30–300 bpm
- Resolution:1 bpm
- Accuracy:±3 bpm
- Update time:1 second
Heart Rate - Adult:15–300 bpm
- Accuracy:±1% or ±1 bpm (whichever is greater)
Respiration Rate - Adult:0–120 BrPM
- Accuracy:±2 BrPM (1–120 BrPM); undefined outside this range
Temperature - Accuracy:±0.1°C (excluding sensor error)
Standard Accessories - NIBP cuff & tube
- ECG cable & electrodes
- Temperature probe
- Lithium-ion battery
- Power cable
- Operator’s manual
Optional Accessories - End-tidal CO₂(optional)
- Recorder (optional)
- Dual NIBP, Nellcor (optional)
Store & Review - ECG:30 minutes of single-lead ECG waveform storage
- Alarm:1,800 alarm event records
- NIBP:400 sets of NIBP measurement data
- Arrhythmia:128 arrhythmia events (with 8-second ECG waveforms)
- Power-off storage:72 hours of trend data + 1 ECG waveform (optional)
ECG Specifications - Modes:
- Standard: 5-lead
- Optional: 3-lead or 12-lead configurations
- Selectable Leads:I, II, III, aVR, aVL, aVF, V1-V6 (optional)
- Gain Settings:AUTO, 0.25×, 0.5×, 1.0×, 2.0×, 4.0×
- Insulation Breakdown Voltage:4,000V AC (50/60Hz)
- Sweep Speeds:6.25 mm/s, 12.5 mm/s, 25 mm/s, 50 mm/s
- Heart Rate Ranges:
- Adult: 10–300 bpm
- Pediatric/Neonatal: 10–350 bpm
- HR Accuracy:±1% or ±1 bpm (whichever is greater)
IBP (Invasive Blood Pressure, Optional) - Channels:2
- Measurement Range:–50 to +300 mmHg
- Units:mmHg or kPa
- Accuracy:±2 mmHg or ±2% (whichever is greater)
Alarm System - Priority Levels:Low, Medium, High
- Alert Types:Audible + visual indicators
- Silence Function:All alarms can be temporarily muted
- Volume Range:45–85 dB (measured at 1-meter distance)
Thermal Recorder (Optional) - Technology:Thermal dot array printing
- Paper Width:50 mm (1.97 inches)
- Paper Speeds:12.5/25/50 mm/sec
- Maximum Traces:3 simultaneous waveforms
EtCO₂(Optional, Microstream Technology) - Measurement Range:
- Units:%, mmHg, or kPa
- Respiratory Rate Range:2–150 breaths per minute (bpm)
Key Features Summary: - Comprehensive Data Storage:ECG, alarms, NIBP, and arrhythmia records
- Flexible ECG Configurations:Supports 3/5/12-lead setups
- High Safety Standards:4,000V AC insulation protection
- Customizable Alarms:Adjustable thresholds and priorities
- Optional Modules:IBP, EtCO₂, and thermal printing for expanded functionality