12-Inch Patient Vital Signs Monitor Multi-Parameter ECG/NIBP/TEMP/RESP/SPO2/PR

12-Inch Patient Vital Signs Monitor Multi-Parameter ECG/NIBP/TEMP/RESP/SPO2/PR
$342.00

Buy Now

12\" Patient Monitor ICU CCU Vital Sign For Hospital ECG NIBP RESP TEMP SPO2 PR
Features:
1. 12.1\" TFT color LCD,800*600dpi
2. Standard 6 para: ECG, SpO2, NIBP, TEMP, RESP, PR
3. Fanless design, quiet, energy-saving and clean
4. With the standard interface, OxyCRG, trend chard, big character interface and view bed,
5. Operation mode: keys and buttons.
6. Display up to 8-channel waveform on one screen.
7. NIBP measurement mode: Manual/AUTO/Continuous, storage for 1000-group NlBP data
8. Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
9. AC/DC, built-in rechargeable lithium battery achieves uninterrupted monitoring.

Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR

Technique Specifications:
ECG
1. Lead Mode: 5 Leads (I, II, III, AVR, AVL, AVF, V)
2. Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
3. Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
① Resolution: 1 BPM
② Accuracy: ±1%
③ Sensitivity >200 uV(Peak to peak)
4. ST measurement range: -2.0 ~ +2.0 mV
① Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified
5. Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
6. Diagnostic: 0.05~130 Hz
7. Monitor: 0.5~40 Hz
8. Surgery: 1~20 Hz

SPO2
1. Measuring Range:35%~100%
2. Resolution: 1%
3. Certainty of measurement: In the range of 70% to 100%, the precision should be ± 3%
4. Pulse Rate: 20-250 BPM
5. Resolution ratio: 1 BPM
6. Accuracy: 2 BPM

NIBP
1. Method: Pulse wave oscillation method
2. Measure mode: Manual / Automatic / Continuous
3. Unit: mmHg, kPa
4. Measure and alarm range:
5.1 Adult Mode
① SYS 30 ~ 255 mmHg
② DIA 10 ~ 220 mmHg
③ MEAN 20 ~ 235 mmHg
5.2 Pediatric Mode
① SYS 30 ~ 255 mmHg
② DIA 10 ~ 220 mmHg
③ MEAN 20 ~ 235 mmHg
5.3 Neonatal Mode
① SYS 30 ~ 135 mmHg
② DIA 10 ~ 110 mmHg
③ MEAN 20 ~ 125 mmHg
6. Resolution ratio: 1mmHg
7. Accuracy: 5mmHg

RESP
1. Method: Impedance between RA-LL or RALA
2. Measurement Range:
① Adult: 0 ~ 120 BrPM
② Neonatal / Pediatric: 0 ~ 150 BrPM
3. Resolution ratio: 1 BrPM
4. Accuracy: 2 BrPM

TEMP
1. Measure and Alarm Range: 0 ~ 50℃
2. Resolution ratio: 0.1℃
3. Certainty of measurement: ± 0.1℃ (without probe error)

Standard Configurations:
Patient Monitor *1
Power Cord *1
Spo2 Sensor *1
Temp Sensor *1
5-lead ECG Cable *1
Electrodes *10
NIBP Cuff *1
NIBP Extension Hose *1
User Manual *1
Ground Line *1 FDAStatement:
Thanksforyourunderstanding!

Buy Now