12-Inch Patient Vital Signs Monitor Multi-Parameter ECG/NIBP/TEMP/RESP/SPO2/PR

12-Inch Patient Vital Signs Monitor Multi-Parameter ECG/NIBP/TEMP/RESP/SPO2/PR
$454.99

Buy Now

Stock available in Mexico warehouse, delivery time within Mexico is 3-7 days!

Core Technical Parameters

Display:12.1-inch TFT LCD true-color displayWaveforms Displayed:Up to 5 waveforms on the standard interfaceMaximum ECG Waveforms:Up to 6 ECG waveforms in full-screen modeECG Leads:Standard 3-lead or 5-leadAdult Heart Rate Range:15–300 bpmRESP Range:0–120 BrPMSpO₂ Range:0–100%SpO₂ Accuracy:±2% within the 70–100% range
PR Range:20–300 bpmTEMP Channels:2 channelsTEMP Range:0–50°CTEMP Resolution:0.1°CNIBP Modes:Manual / Automatic / STATAdult NIBP Range:SYS: 40–270 mmHg / DIA: 10–215 mmHg / MAP: 20–235 mmHgPower Supply:AC 100–240V, 50/60HzMaximum Power Consumption:70VABattery:11.1V 2200mAh rechargeable lithium Size:342*252*139.5mm


Packing List:

8000C Patient Monitor Main Unit x 1PC

Accessories Display

1. ECG electrodes × 5

2. Power cord × 1

3. Blood pressure extension tube × 1

4. ECG lead wire × 1

5. Ground wire × 1

6. Temperature probe × 1

7. Instructions × 1

8. Blood pressure cuff × 1

9. Oxygen probe × 1

▲ 1 ECG Specification
1.1 Lead configuration :Standard 3-lead or 5-lead
3-lead :RA, LA, LL,Lead method:I,II,III
5-lead :RA, LA, LL, RL, V,Lead Gain variation :0.25, .5, 1, 2. Automatically,Gain change per minute < 0.66%/min,Total gain change in 1 hour < ±10%
1.3 HR Range :
Adult :15 ~ 300bpm (beat/minute)
Precision : ±1% or ±1bpm,the larger prevails
Resolution :1 bpm(beat/minute)
1.4 Sensitivity :> 200 uV (Peak-to-peak value)
1.5 Input Impedance :> 5 (megohm)
1.6 Bandwidth
Diagnostic mode :0.05~130Hz
Monitoring Mode :0.5~40Hz
Operation mode :1~20Hz
1.7 Common Mode rejection Ratio
Diagnostic mode > 90 dB
Monitoring Mode > 100 dB
Operation mode > 100 dB
1.8 Pole Polarization Vvoltage Range :±300mV
1.9 Pacing Pulse Test
Test pacing pulse in accordance with the following conditions :
Amplitude : ±2 mV ~ ±700mV
Width : 0.1ms ~ 2ms
Risetime : 10us~100µs
1.10 Pacing pulse inhibition
When pacing analysis switch is on, pacing pulse in accordance with the following conditions are
restrained, but affection against HR calculation.
Amplitude : ±2 mV ~ ±700mV
Width : 0.1ms ~ 2ms
Risetime : 10us ~ 100µs
1.11 Signal Range :±8 mV (Peak-to-peak value)
1.12 Calibrating Signal :1mV(Peak-to-peak value),precision ±5%
1.13 ST Segment Measuring Volume
Measuring range : -2.0mV ~ +2.0mV
Measuring precision : Ranging -0.8 mV ~ +0.8mV, measuring error is ±0.02mV or ±10%,. The larger prevails. No definition for other ranges.
▲ 2 RESP Specification
2.1 Measuring Method :RA-LL impedance
2.2 RESP Impedance Measuring Range :0.3~3Ω
2.3 Base Impedance Range :200~4000Ω
2.4 Bandwidth :0.1~2.5Hz
2.5 RESP Rate
Range
Adult :0~120BrPM
Resolution :1 BrPM
Precision :±±2 BrPM
2.6 Asphyxia Alarm :10~40 seconds
▲ 3 NIBP Specification
3.1 Measuring Method :Pulse wave oscillometry
3.2 Work Mode :Manual/Automatic/STAT
3.3 Measuring Interval of Automatic Measuring Mode minute(s)
3.4 Measuring Time of STAT Mode :5 minutes
3.5 PR range :40 – 240 bpm
3.6 Measuring Range and Precision
Range
Adult :Systolic blood pressure 40~270mmHg
Diastolic blood pressure 10~215mmHg
Mean blood pressure 20~235mmHg
Static pressure range : 0~300mmHg
Static pressure precision : ±3mmHg
Pressure precision : Max. average error: 5mmHg;Max. standard deviation: 8mmHg
3.7 Overvoltage protection
Adult mode :300 mmHg
▲ 4 SpO2 Specification
4.1 SpO2
Range : 0~100%
Resolution : 1%
Precision : 70~100%:±2%
0%~69% :no definition given
4.2 PR
Range 20~300bpm
Resolution 1bpm
Precision ±±3bpm
▲ 5 TEMP Specification
5.1 suitable for temperature sensor :YSI series,CYF series
5.2 Channel quantity :2 channels
5.3 Measuring
Range :0~50℃
Resolution :0.1℃
Precision : ±0.1℃(excluding sensor error)
▲ 6 IBP Specification
Label :ART, PA, CVP, RAP, LAP, ICP, P1, P2
Measuring and alarm range
ART :0 ~ 300 mmHg
PA :-6 ~ 120 mmHg
CVP/RAP/LAP/ICP :-10 ~ 40 mmHg
P1/P2 :-10 ~ 300 mmHg
Press Sensor
Sensitivit : 5 uV/V/mmHg
Impedance : 300-3000Ω
Resolution :1 mmHg
Accuracy :±2% or ±1mmHg, which great
Actualization interval :about 1 Sec.
▲ 7 CO2 Specification
Side stream :
7.1 measurement :Infrared radiation absorption technique
7.2 measurement range :0 ~ 99mmHg
7.3 precision* :0 ~ 40mmHg : ±2mmHg
41 ~76mmHg : ±5%
77~99mmHg : ±10%
7.4 resolution :1mmHg
7.5 drift :To meet the requirement of accuracy within 6 hours
7.6 pumping rate :70ml/min, 100ml/min
7.7 pumping rate control accuracy :15% or 15ml/min big
7.8 module start time
The < 1min, enter the precision measurement of the state,After entering 1min, the accuracy of measuring state
7.9 AwRR measuring range :0 ~120BrPM: ±2
7.10 precision
0 ~70BrPM : ±2BrPM
>70BrPM : ±5BrPM
7.11 response time
The use of adult sampling tube :
< @ 5.5s 100ml/min
< @ 7s 70ml/min
7.12 delay time
The use of adult sampling tube :
< @ 5s 100ml/min
< @ 6.5s 70ml/min
7.13 asphyxia alarm delay
AwRR : 10 ~ 40s


Buy Now