Renishaw SCR200 CMM Stylus Module Change Rack New in Box

Renishaw SCR200 CMM Stylus Module Change Rack New in Box
$5,350.00

Buy Now

This listing is for brand new in box Renishaw SCR200 Automatic 6 position change rack for DCC Coordinate Measuring Machines. Includes a mounting washer location piece. If you would like any additional TP200 probing please let us know.Also available in new open box rack for reduced price please let us know if you have any questions.MSRP: $6855SCR200

Change rack for TP200 stylus modules.

The SCR200 provides automatic, high speed changing between up to sixTP200stylus modules and is powered by the separate probe interfacePI 200-3, providing features to facilitate safe stylus changing.

The SCR200 is available in low force and standard force kits, where each kit comprises one SCR200 plus three stylus modules of the same force.

Height

190 mm (7.84 in)

Width

245 mm (9.65 in)


Dimensions

Specification

Weight

0.75 kg

Mounting orientation

Vertical or horizontal

Mounting fixture

Single stud (M8, M10)

Number of ports

6

Repeatability of stylus change (2σ) at 50 mm

Automatic ≤1 μm
Manual ≤2 μm

Entry speed

Unrestricted

Module pull-off force

800 g maximum

Overtravel protection

Electromechanical (5° minimum deflection)

LED indicators

Power

Green

Status

Red (flashing during probe inhibit)

Change cycle detection

Optoelectronic beam system with Hall effect proximity sensor

Multi-rack usage

Up to two SCR200 units (12 ports) may be connected with a special cableInstallation

All alignment requirements and port docking co-ordinates can be established with only eight probing points. No control signals from the CMM are required.

Alignment adjustment

XY rotational only ±0.1 mm

Docking tolerance

X ±0.17, Y ±1.5 mm, Z ± 2 mm

Power supply / control

PI 200-3 interface

Cable length

20 m maximum (PI 200-3 to SCR2000)

Cable connection

6-pin miniature DIN socket

Set-up time

<30 minutes

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design