Brief IntroductionMS100 SpO2 Simulator is a kind of Separated SpO2 simulator, small and light. It can perform a series of tests for the oximeter by simulation means, and gives cognizance of veracity about the oximeter.Because the oximeter manufacturer may use different R-curves, some R-curves used abroad currently have been embedded.
Features◆ Separated connection between simulator probe and host, operation and test are more convenient.◆ 262K color and 320*240 TFT, adjustable brightness level.◆ Film key-press, makes the operation more comfortable.◆ Power with chargeable lithium battery, can display the charge information of battery.◆ Key volume, can open or close.
Main Functions◆ Oxygen saturation simulation;◆ Pulse rate simulation;◆ Patient state simulation preset;◆ Can test the reaction time of device;◆ Can simulate the SpO2 and pulse rate under different amplitude;
◆ Can test the performance of device under different interference source;◆ Can select different R-curve.
Main Parameters
◆ SpO2Measuring range: 35%~100%Resolution:1%Error: When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is 74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%.◆ Pulse rate
Measuring range:25bpm~250bpm Resolution:5bpmError:1%±1bpm◆ Amplitude
Measuring range:0.000%~20.000%Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.◆ Patient state24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.
◆ Voltage
DC 3.6V~4.2V◆ Power Supply
Voltage 3.7 rechargeable lithium battery × 1◆ Battery working lifeCharge and discharge no less than 500 times.
Accessaries
◆ A MS100 user manual◆ A 5.0V adaptor
MS400 Multiparameter Simulator is a portable device, which can provide comprehensive physiological waveform to content general test and train requirement.
It can check the monitor rapidly near the bed, also can test the quality warranty of equipment, monitor and remote therapy equipment, At the same time,
it can be used as the training of distinguishing from arrhythmia waveforms to the nurses.
3.5-inch color TFT touch-screen, 320*240 pixels, friendly operation interface.Display the output waveforms synchronously, which is convenient for user to compare with the test equipment.It integrates the functions of SD socket interface, user can output the custom waveform by this device.Built-in templates list to provide the waveform that is expressed by each preset sequence number,which is convenient for searching.Two operation interfaces:Chinese and English.Operate with keystroke and touch-screen expediently and rapidly.Built-in 3.7V/4000mAh(Rechargeable alkaline battery).Optical external power: AC 220V, 50Hz or AC 120V, 60Hz
Arrhythmia
Conventional: All leads have the same voltage with the II-lead as the referenceAmplitude: 0.5,1.0,1.5 and 2.0mVThe accuracy of Amplitude: ±2%Rate: and 350 BPMartifacts: 50 or 60 Hz, muscle, baseline drift and breathingThe elevation of the ST segment: -0.8 mV to +0.8 mV, the step is 0.1 mVThe default: 80 BPM,1mV
ArrhythmiaAtrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, AtrialTachycardia, Nodal Rhythm, Supraventricular TachycardiaVentricular: Vent Fib (coarse), Vent Fib (fine), Premature Ventricular Contraction (PVC) 6/min,PVCs 12/min, PVCs 24/min, Freqent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5PVCs, Run 11 PVCs, Vent Tachycardia, AsystolePremature Beat: Atrial Premature Atrial Contraction (PAC), Nodal PNC, Left Ventricular FocusPVC1, Early Left Ventricular Focus PVC1, Right Ventricular Focus PVC1, Early RightVentricular Focus PVC1, R on T Left Ventricular Focus, R on T Right Ventricular Focus, Multifocal PVCConduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block
Performance Testingamplitude0.5,1.0,1.5 and 2.0mVThe accuracy of Amplitude: ±2%Pulse: 30 and 60 BPM, the width of pulse wave is 60 msSquare: 0.125 and 2.0 HzTriangle: 2.0 and 2.5 HzSine: .0.5, 5, 10, 40, 50, 60 and 100 HzRate:15, 20, 25, 30, 40, 60, 80, 100, 120, 140, 160, 180, 200, 220, 240, 260, 280, 300, 320, 340 and 350 BPMThe accuracy of Rate: ±1%
RespirationRespiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIINRespiration Impedance: 0.2, 0.5, 1.0 and 3.0 ΩBaseline Impedance:500,1000,1500 and 2000Apnea: 12 s, 22 s, 32 ssimulator with adjustable heart rate/12-lead output33 kinds of Arrhythmia waveformsPacemakerTwo IBP channelsVariety of respiratory impedance,apnea pauses (0 BrPM) of 12, 22 and 32 seconds.Standard calibrationExport square,triangle and sine with adjustable frequencyIBPThe default: 00/00mmHgDynamic IBP
Channel 1: Artery 120/80mmHgRadial 120/80mmHgLeft Ventricle 120/00mmHgRight Ventricle 25/00mmHgChannel 2: Artery 120/80mmHgRadial 120/80mmHgLeft Ventricle 120/00mmHgRight Atrium 15/10mmHgRight Ventricle 25/00mmHgPulmonary Artery 25/10mmHgLeft Atrium 14/4mmHgStatic-Pressure LevelsChannel 1: 0, 80, 160, 240, 320 and 400mmHgChannel 2: 0, 50, 100, 150, 200 and 250mmHg