CONTEC MS100 MS200 MS400 SPO2 PR NIBP ECG IBP TEMP Non-Invasive Simulator

CONTEC MS100 MS200 MS400 SPO2 PR NIBP ECG IBP TEMP Non-Invasive Simulator
$1,400.00

Buy Now

Store CategoriesStore Categories
  • Product Description

    MS100 SpO2 Simulator is a kind of Separated SpO2 simulator, small and light. It can perform a series of tests for the oximeter by simulation means, and gives cognizance of veracity about the oximeter.
    Because the oximeter manufacturer may use different R-curves, some R-curves used abroad currently have been embedded.
    Features:
    ◆ Separated connection between simulator probe and host, operation and test are more convenient.
    ◆ 262K color and 320*240 TFT, adjustable brightness level.
    ◆ Film key-press, makes the operation more comfortable.
    ◆ Power with chargeable lithium battery, can display the charge information of battery.
    ◆ Key volume, can open or close.
    Functions:
    ◆ Oxygen saturation simulation;
    ◆ Pulse rate simulation;
    ◆ Patient state simulation preset;
    ◆ Can test the reaction time of device;
    ◆ Can simulate the SpO2 and pulse rate under different amplitude;
    ◆ Can test the performance of device under different interference source;
    ◆ Can select different R-curve.
    Parameters:
    ◆ SpO2
    Measuring range: 35%~100%
    Resolution:1%
    Error: When SpO2 is 75%~100%, the error is the larger between ±2% and ±P(P denotes the precision of the tested oximeter); when SpO2 is 74%~50%, the error is the larger between ±2% and ±P; no define when SpO2 is less than 50%.
    ◆ Pulse rate
    Measuring Amplitude
    Measuring range:0.000%~20.000%
    Resolution:1% for 1.000%~20.000%; 0.1% for 0.100%~0.900%; 0.025% for 0.000%~0.075%.
    ◆ Patient state
    24 conditions presetting and 8 conditions as default after start. The number of condition can be adjusted by Motion level setup.
    ◆ Voltage
    DC 3.6V~4.2V
    ◆ Power Supply
    Voltage 3.7 rechargeable lithium battery × 1
    ◆ Battery working life
    Charge and discharge no less than 500 times.
    Qualification:
    Passed FDA/CE
    Package included:
    1XMS100 SpO2 Simulator
    1XMS100 SpO2 Simulator Probe
    1XPower cable
    1X5.0V Power adaptor
    1X User manual

    MS400 Multiparameter Simulator is a portable device, features in small volume and light weight. It can simulate accurately 12-lead ECG, Respiration, Temperature, 2-channel IBP or 4-channel IBP. And it can be tested in where the monitor is used.
    Features:
    Simulate 35 kinds of arrhythmia (including Atrial, Ventricular, Premature Beat and Conduction Defects) and pacemaker waveforms (including Asynchronous, Demand Occ Sinus, Demand Freq Sinus, A/V Sequential, Non Capture, Non Function).
    Simulate four-channel IBP data.
    Simulate respiration signal with adjustable respiration rate, impedance and baseline impedance, and three kinds of apnea data.
    Simulate four kinds of temperature data.
    Simulate square wave, triangle wave, pulse wave and sine wave with adjustable frequency.
    Simulate standard ECG calibration, adult and pediatric ECG signal.
    ECG waveform complied with the standard of ANSI/AAMI EC13-2002, AHA, MIT ECG database, other ECG database and user-defined waveform data stored in TF card can be displayed by the simulator and exported to the equipments to be tested.
    Each waveform can be displayed by sliding the 3.5\'\' TFT touch screen, easy to operate.
    Power supply: rechargeable lithium battery or linear adapter, which reduces interference.
    Optional operation modes: keys and touch All leads have the same voltage with the II-lead as the reference
    Amplitude: 0.5,1.0,1.5 and 2.0mV
    ECG Rate: and 350 BPM
    ECG artifacts: 50 and 60 Hz, muscle, baseline and breathing
    The elevation of the ST segment: +0.8 to -0.8 mV, the step is 0.1 mV
    Arrhythmia:
    Atrial: Atrial Fib(coarse), Atrial fib(fine), Atrial Flutter, Sinus Arrhythmia, Missed Beat, Atrial Tachycardia, Nodal Rhythm, Supraventricular Tachycardia
    Ventricular: Vent Fib (coarse), Vent Fib (fine), PVCs 6/min, PVCs 12/min, PVCs 24/min, Frequent Multifocal, Bigeminy, Trigeminy, Paired PVCs, Run 5 PVCs, Run 11 PVCs, Vent Tachycardia, Asystole
    Premature Beat: Atrial PAC, Nodal PNC, PVC1 LV Focus, PVC1 E LV Focus, R on T LV Focus, PVC2 RV Focus, PVC2 E RV Focus, R on T RV Focus, Multifocal PVC
    Conduction Defects: First Degree Heart Block, Second Degree Heart Block, Third Degree Heart Block, Right Bundle Branch Block, Left Bundle Branch Block
    Four IBP Channels:
    The default: 00/00mmHg
    Dynamic IBP(unit: mmHg)
    Channel 1:
    Artery: 120/80
    Radial: 120/80
    Left Ventricle: 120/00
    Right Ventricle: 25/00
    Channel 2:
    Artery: 120/80
    Radial: 120/80
    Left Ventricle: 120/00
    Right Atrium(CVP): 15/10
    Right Ventricle: 25/00
    Pulmonary Artery: 25/10
    Pulmonary Wedge: 10/2
    Left Atrium: 14/4
    Channel 3:
    Artery: 120/80
    Radial: 120/80
    Left Ventricle: 120/00
    Right Atrium(CVP): 15/10
    Right Ventricle: 25/00
    Pulmonary Artery: 25/10
    Pulmonary Wedge: 10/2
    Left Atrium: 14/4
    Channel 4:
    Auto Swan-Ganz (every 15 seconds): RA(CVP), RV, PA, PAW (Pulmonary Wedge)
    Man Swan-Ganz: press ENTER key to change every time
    Static-Pressure Levels
    Channel 1: 0, 80, 160, 240, 320 and 400mmHg
    Channel 2: 0, 50, 100, 150, 200 and 250mmHg
    Channel 3: 0, 20, 40, 60, 80 and 100mmHg
    Channel 4: P4 tracks the static pressure levels of P3
    Respiration:
    Respiration Rate: 0 (Apnea), 15, 20, 30, 40, 60, 80, 100, 120 and 150 R/MIN
    Impedance: 0.2, 0.5, 1.0 and 3.0 Ω
    Baseline impedance: 500, 1000, 1500, 2000Ω
    Apnea: 12 s, 22 s, 32 s
    Temperature:
    Four temperature: 0℃(32°F), 24℃( 75°F), 37℃(98.6°F), 40℃(104°F)
    Physical characteristic:
    Dimension 18.86 cm(L)×12.50 cm(W)×4.32 cm(H)
    Net weight about 1.4kg
    Package included:
    1XMS400 Multiparameter Simulator
    1X Temperature cable
    1XIBP cable
    1XPower adapter
    1XUser manual
    1XPackaging box

    MS200 NIBP Simulator is a multi-purpose test instrument for use with oscillometric Non-Invasive Blood Pressure(NIBP) Monitors. The appearance is concision ,operation is simple and convenient,with its internal pump, the Simulator can generate pressures up to 400 mmHg (53.3 kPa).The Simulator provides dynamic blood pressure simulations, static pressure calibration, automated leak testing, and pressure relief valve testing.You can quickly and exact analyse different NIBP Monitors.
    Features:
    Provides pressure gauge testing,pressure leak testing,relief valve testing functions .
    Build-in pump provides pressure source with leak and pressure relief tests
    NIBP simulations for both arm and wrist cuffs.
    Provides adult,neonate, eight variations patients conditions,user-defined simulations.
    Provides arrhythmias,respiratory artifact simulations.
    Built-in air chamber to simulate adult and neonate cuff.
    65k colors,4.3\"\" LCD display.
    Technical index
    Pressure mmHg,0.1 kPa,1 cmH2O,1 inH2O,0.1 psi
    Accuracy:0-300 mmHg:±0.5% of reading ±1 mmHg;
    301-400 mmHg:±2%of reading
    Pressure Generator:
    Static Pressure Range:50 mmHg-400 mmHg
    Resolution:1mmHg
    Difference between target pressure and actual pressure :±10 mmHg from 100-400 mmHg with a minimum volume of 300 cc
    Internal leak rate:
    <2 mmHg per minute, with a minimum volume of 300 cc
    Pressure Leak Test:
    Pressure generate up to 400 mmHg (53.3 kPa) with internal pump.The screen always show the peak pressures and the real-time pressures.Leak rate displayed after 10 seconds.
    Pressure Relief Test:
    Pressure generate up to 400 mmHg (53.3 kPa) with internal pump,Displays peak pressure.
    Standard BP Simulations:
    Preset blood pressure:
    1#: BP: 120/80(93) HR: 80 Pulse Volume: 0.68
    2#: BP: 150/100(116) HR: 80 Pulse Volume: 0.65
    3#: BP: 200/150(166) HR: 80 Pulse Volume: 0.60
    4#: BP: 255/195(215) HR: 80 Pulse Volume: 0.55
    5#: BP: 60/30(40) HR: 80 Pulse Volume: 0.75
    6#: BP: 80/50(60) HR: 80 Pulse Volume: 0.71
    7#: BP: 100/65(76) HR: 80 Pulse Volume: 0.69
    Patient Conditions:
    BP Simulations
    Healthy: BP: 120/80(93) HR:75 Pulse Volume: 0.68
    Weak Pulse: BP: 110/80(90) HR:95 Pulse Volume: 0.50
    Mild Exercise: BP: 140/90(106) HR:120 Pulse Volume: 1.00
    Strenuous Exer: BP: 140/90(106) HR:162 Pulse Volume: 1.40
    Obese: BP: 120/80(93) HR:90 Pulse Volume: 0.50
    Geriatric: BP: 150/110(123) HR:95 Pulse Volume: 0.40
    Tachycardia: BP: 120/105(110) HR:130 Pulse Volume: 0.40
    Bradycardia: BP: 120/60(80) HR:45 Pulse Volume: 1.10
    Arrhythmia Simulations:
    Premature Atrial Contract 1,Premature Atrial Contract 2,Premature Ventricular Contract,Atrial Fib and PVCs
    Respiratory Artifacts
    Spontaneous Breathing 1,Spontaneous Breathing 2,Spontaneous Breathing 3,Controlled Ventilation
    Neonate simulations
    User can select External or Internal Neonate;
    1#: BP: 35/15 HR: 120bpm Pulse Volume: 0.11
    2#: BP: 60/30 HR: 120bpm Pulse Volume: 0.10
    3#: BP: 80/50 HR: 120bpm Pulse Volume: 0.10
    4#: BP: 100/70 HR: 120bpm Pulse Volume: 0.10
    Wrist simulations
    1#: BP:120/80(93) HR: 80bpm Pulse Volume: 0.50
    2#: BP:160/100(120) HR: 80bpm Pulse Volume: 0.50
    3#: BP:80/55(63) HR: 80bpm Pulse Volume: 0.50
    User-Defined simulations
    Allows the operator to define blood pressure simulations.
    Systolic(mmHg) 20-250
    Diastolic(mmHg) 10-200
    Heart Rate,(bpm) 30-250
    Pulse Volume,(cc) 0.1-2.4
    Simulant characteristics:
    The maximum pulse volume:2.4cc
    The maximum heart rate:250bpm,200bpm at pulse volume>2.00cc.
    Internal Adult cuff volume:20cc
    Internal neonate cuff volume:300cc
    Blood pressure units: mmHg,kPa
    Heart Rate Accuracy:±1BPM
    Patient Conditions:
    Weak pulse, Tachycardia,Obese,Geriatric ±1%±1BPM
    Mild exercise±1.5%±1BPM
    Strenuous exercise±3%±1BPM
    Display
    65k colors 4.3 inch TFT Display, brightness can be changed.
    Power
    AC100 - 240 V 50/60 Hz, 60 VA
    Environmental Conditions:
    Working temperature: 15℃ to 40℃(59℉ to 104℉)
    Storage temperature: -20℃ to +65℃(-4℉ to +149℉)
    Relative humidity: < 90%,No condensation.
    Size (L x W x H):27 cm x 26.5 cm x 13.2 cm
    Weight:About 4kg
    Package included:
    1XMS200 NIBP Simulator
    1XPower cord
    2XFuse
    1XUser \'s Manual

  • Returns Policy
  • Shipping Policy
  • Contact us
  • response
Returns Policy
Shipping Policy
    SpeedPAK7~15daysSome remote areas require about 25 working days FEDEX/DHL/UPS /EMS2~7days Quick response,contact us! 2. Item will be shipped out within1-2 working days(except weekends and holidays) after the payment is cleared or received.
Contact us
response

    We greatly appreciate yourPOSITIVE response. Pleasedo NOT leave negative or neutral response without any contact. If you haven’t received item in 30 days, please contact us and we will arrange refund.

Copyright © 2023 Dianxiaomi

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Popular Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design