Honeywell Simplex GSA4098-9714 TrueAlarm Optical Detector Honeywell Simplex GSA4098-9714 TrueAlarm Optical Detector id: 407344841970SKU: GSA4098-9714
Simplex GSA4098-9714 TrueAlarm Intelligent Addressable Optical Detector Head
The Simplex GSA4098-9714 is an intelligent addressable optical detector head designed for compatible Simplex TrueAlarm fire alarm systems. It uses advanced light-scattering technology to monitor airborne combustion particles and communicate sensing information to the connected fire alarm control panel.
Additionally, the detector supports IDNet and MAPNET II communication. Furthermore, its automatic environmental compensation, adjustable sensitivity, and low-profile construction support professional fire alarm installations.
USA-Assembled TrueAlarm Detector
The GSA4098-9714 belongs to the Simplex TrueAlarm intelligent detector family.
Specifically, the GSA prefix identifies a version assembled in the United States. Therefore, this model provides a distinct ordering option within the 4098-9714 product family.
Additionally, manufacturer documentation identifies the GSA4098-9714 and standard 4098-9714 as optical detector heads.
However, the manufacturing prefix does not indicate an additional thermal sensing function. Consequently, installers should not confuse this model with a combination optical and heat detector.
Advanced Optical Sensing Technology
The detector uses a stable pulsed LED light source and a silicon photodiode receiver.
During normal operation, airborne particles enter the sensing chamber. Meanwhile, the electronics monitor changes in the received light signal.
When combustion particles enter the chamber, they scatter light toward the optical receiver.
As a result, the detector sends sensing information to the compatible fire alarm control panel.
Therefore, the control panel can evaluate the condition and initiate an alarm when the selected threshold is reached.
Additionally, the sensing chamber supports 360-degree air entry. Consequently, the detector can monitor airborne particles approaching from multiple directions.
Intelligent Addressable Communication
The Simplex GSA4098-9714 supports compatible IDNet and MAPNET II signaling circuits.
Unlike conventional detectors, TrueAlarm sensors communicate individual analog sensing values to the control panel.
Therefore, the system can identify the affected detector and evaluate its operating condition.
Additionally, compatible panels provide individual device identification and maintenance reporting.
As a result, technicians can locate activated devices and investigate abnormal conditions more efficiently.
However, the detector requires compatible Simplex control equipment. Consequently, technicians must verify the panel, signaling circuit, and mounting base before installation.
Automatic Environmental Compensation
The TrueAlarm system continuously monitors detector sensing performance.
Over time, dust and airborne contaminants may accumulate inside the optical chamber.
Therefore, the compatible fire alarm control panel evaluates gradual changes in the detector’s response.
Additionally, the system compensates for environmental changes within its approved operating limits.
As a result, technicians can identify contamination-related maintenance conditions.
Furthermore, routine inspection and cleaning help maintain dependable operation.
Adjustable Sensitivity Settings
The detector supports sensitivity selection through compatible Simplex control panels.
For example, manufacturer documentation identifies special-application settings of 0.2%, 0.5%, and 1.0% obscuration per foot.
Additionally, the documented standard operating sensitivity range is approximately 1.25% to 3.1% obscuration per foot.
Therefore, qualified technicians can select approved sensitivity settings for the protected environment.
However, special-application settings require careful evaluation. Consequently, installers must verify the applicable listing requirements and manufacturer instructions.
360-Degree Air Entry Design
The GSA4098-9714 features a sensing chamber designed for 360-degree air entry.
As a result, airborne particles can enter the detector from multiple directions.
Additionally, the housing incorporates insect screening to help protect the sensing chamber.
Furthermore, the detector is designed to reduce unwanted airflow entering from behind the mounting surface.
Therefore, the sensing chamber can operate according to the approved installation design.
Key Features
- Simplex TrueAlarm Series
- Exact model GSA4098-9714
- USA-assembled GSA variant
- Intelligent addressable optical detector head
- Pulsed LED light-scattering technology
- Silicon photodiode receiver
- 360-degree air-entry design
- Built-in insect screening
- IDNet communication support
- MAPNET II communication support
- Automatic protocol selection
- Individual addressable device identification
- Analog sensing information
- Panel-controlled sensitivity settings
- Automatic environmental compensation
- Contamination monitoring
- Maintenance condition reporting
- Pre-alarm capability with compatible panels
- Low-current operation
- Approximately 80 µA average current in historical 4098-9714 documentation
- Compatible standard and relay mounting bases
- Optional remote alarm indication
- Plug-in detector construction
- Professional installation and testing required
Continuous Sensitivity Monitoring
The TrueAlarm system monitors individual detector sensitivity.
For example, the control panel can evaluate changes in the detector’s response over time.
Additionally, compatible panels provide maintenance information when sensing conditions change.
As a result, technicians can identify detectors requiring cleaning or further inspection.
Furthermore, automatic sensitivity monitoring supports professional system maintenance.
However, it does not eliminate required physical inspections or functional testing.
Compatible Mounting Bases
The GSA4098-9714 supports manufacturer-approved Simplex TrueAlarm mounting bases.
For example, the 4098-9792 provides a standard mounting arrangement.
Additionally, the 4098-9789 supports compatible remote alarm indication or relay accessories.
Meanwhile, the 4098-9791 provides connections for approved supervised relay applications.
Furthermore, the 4098-9780 is another documented base option for compatible systems.
However, base compatibility depends on the installed fire alarm control panel and system configuration. Therefore, technicians must verify the exact combination before installation.
Low-Current Operation
Historical Simplex documentation identifies an average operating current of approximately 80 microamps for the 4098-9714 sensor family.
Additionally, the detector receives operating power and communication through the compatible addressable circuit.
Therefore, a separate conventional detector power connection is not normally required.
However, the exact electrical requirements depend on the control equipment and mounting base.
Consequently, installers must use the applicable manufacturer documentation for circuit calculations.
Environmental Operating Requirements
The manufacturer specifies a general operating temperature range of 15°F to 122°F (-9°C to 50°C).
However, the UL-listed operating temperature range is 32°F to 100°F (0°C to 38°C).
Additionally, the detector supports relative humidity from 10% to 95%, non-condensing.
Furthermore, the manufacturer’s newer documentation identifies an air velocity rating of 0 to 4,000 feet per minute.
Therefore, technicians should verify the applicable document revision and installation requirements.
Typical Applications
The Simplex GSA4098-9714 supports compatible commercial and institutional fire alarm systems.
For example, applications may include offices, schools, hospitals, hotels, warehouses, retail facilities, and industrial buildings.
Additionally, its intelligent addressable communication supports professional maintenance of existing Simplex systems.
Furthermore, its plug-in construction allows compatible replacement work without automatically replacing the mounting base.
However, technicians must confirm the base and panel compatibility before substitution.
Installation and Compatibility
Before installation, technicians should confirm the fire alarm control panel, signaling protocol, and mounting base.
Next, they should inspect the detector housing, sensing chamber, and electrical contacts.
Additionally, they must verify sensitivity settings and environmental requirements.
Qualified fire alarm professionals should install and test the detector according to Simplex instructions.
Afterward, they should confirm communication, alarm response, and maintenance reporting.
Therefore, the detector should return to service only after the required testing is complete.
Maintenance and Replacement
Regular maintenance helps preserve dependable detector operation.
First, technicians should inspect the sensing chamber for dust, debris, and physical damage.
Next, they should review the detector’s maintenance status through the compatible control panel.
Additionally, they should perform the required functional tests.
However, an untested detector should not be described as fully operational.
Consequently, service personnel must confirm the device’s condition before placing it into the Simplex GSA4098-9714 provides intelligent optical fire sensing for compatible TrueAlarm addressable systems.
Additionally, its USA-assembled designation, IDNet and MAPNET II communication, automatic environmental compensation, and flexible mounting options support professional fire alarm maintenance.
Therefore, this detector head is a practical component for approved Simplex installations when compatibility, condition, and safety requirements have been verified.
GSA4098-9714 Datasheet
Shipping Services
We offer the following shipping services:
- USPS Priority Mail
- UPS Ground
If you would like your package shipped differently, please contact us.
Payment
We accept the following payment Card
American ExpressDiscoverDo not hesitate to contact us if you have any questions.
International Shipping
- If you are outside the United States and need our items you can contact us through an message.
- We offer 2 shipping options if they do not work, please contact us and we will make changes for you.
- We process all orders the same day when we receive the payment before 5:30 PM ET.
- Daily we strive to provide the best service to our buyers and give the highest satisfaction but if for some reason there is an error to receive your purchase please contact us before leaving a negative response.
Warranty
Please be aware that we are not authorized distributors. We can not guarantee the featured item will have the manufacturer\'s warranty or support.
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.