Honeywell Simplex GSA4098-9602 TrueSense Detector Honeywell Simplex GSA4098-9602 TrueSense Detector id: 407358168534SKU: GSA4098-9602
Simplex GSA4098-9602 TrueAlarm TrueSense Optical and Heat Detector
The Simplex GSA4098-9602 is a TrueAlarm TrueSense optical and heat detector designed for compatible conventional fire alarm systems. It combines optical sensing technology with electronic thermal detection to monitor developing fire conditions.
Additionally, the detector provides four detection modes, including fixed-temperature heat sensing and rate-of-rise monitoring. Furthermore, its intelligent TrueSense analysis evaluates optical and thermal activity together.
As a result, the detector offers multiple detection methods in one compact device.
Advanced TrueSense Detection Technology
The Simplex GSA4098-9602 uses TrueSense technology to evaluate optical and thermal sensing information.
First, its optical chamber monitors airborne combustion particles through light-scattering technology. Meanwhile, a fast-response thermistor monitors changes in surrounding temperature.
Additionally, the onboard microprocessor analyzes the relationship between these sensing activities.
As a result, the detector can recognize conditions associated with developing fires.
Furthermore, TrueSense analysis supports improved response to certain rapidly developing, hot-flaming fire conditions.
Four Independent Detection Modes
The detector incorporates four distinct detection functions.
First, optical sensing monitors airborne combustion particles. Second, fixed-temperature sensing monitors for temperatures reaching 135°F.
Additionally, rate-of-rise sensing detects rapid temperature increases under specified conditions.
Finally, TrueSense analysis correlates optical and thermal activity to identify developing fire conditions.
Therefore, the detector can initiate an alarm when any supported detection mode reaches its threshold.
135°F Fixed-Temperature Heat Detection
The GSA4098-9602 includes an electronic fixed-temperature heat detection function rated at 135°F (57°C).
Specifically, a fast-response thermistor monitors ambient temperature.
When the temperature reaches the specified threshold, the detector initiates an alarm.
Unlike non-restorable mechanical thermal elements, this electronic sensing mechanism is resettable.
Consequently, the detector may return to normal after the alarm condition clears and the system is properly reset.
However, qualified personnel must inspect and test the device before returning it to service.
Rate-of-Rise Heat Detection
The detector also monitors rapid temperature increases.
Specifically, its rate-of-rise function activates at temperature increases of 20°F per minute (11°C per minute) or greater.
However, this function operates only when the ambient temperature exceeds 90°F (32°C).
Therefore, installers must consider environmental temperature conditions when selecting detector locations.
Additionally, the manufacturer recommends avoiding areas with excessive temperature fluctuations.
Consequently, correct placement helps reduce unwanted alarm conditions.
Optical Fire Sensing
The optical chamber monitors airborne combustion particles using light-scattering technology.
During normal operation, airborne particles enter the louvered sensing chamber.
Meanwhile, the electronics evaluate changes in the optical signal.
When the sensing threshold is reached, the detector can initiate an alarm.
Additionally, the chamber design helps direct airflow toward the sensing elements.
Therefore, the detector supports approved ceiling and wall mounting applications.
TrueAlarm Environmental Compensation
The detector includes TrueAlarm sensitivity drift compensation.
Over time, dust and airborne contaminants may accumulate inside the optical chamber.
Therefore, the onboard electronics monitor gradual changes in sensing performance.
Additionally, the detector adjusts its reference point within the manufacturer’s compensation limits.
As a result, the system can reduce sensitivity changes caused by contamination or component aging.
Furthermore, the detector provides maintenance indications when contamination approaches the compensation limit.
Conventional Fire Alarm Compatibility
The Simplex GSA4098-9602 operates through a compatible conventional initiating device circuit.
Unlike addressable TrueAlarm sensors, this model does not use IDNet or MAPNET II communication directly.
Instead, its compatible mounting base determines the approved two-wire or four-wire circuit configuration.
For example, the 4098-9788 provides a two-wire mounting arrangement.
Meanwhile, the 4098-9682 supports four-wire operation with auxiliary alarm relay contacts.
Additionally, the 4098-9683 provides a two-wire base with an auxiliary alarm relay.
Therefore, technicians must verify the exact base and control panel compatibility before installation.
Key Features
- Simplex TrueAlarm TrueSense Series
- Exact model GSA4098-9602
- Conventional optical and heat detector
- Four independent detection modes
- Optical light-scattering sensing
- 135°F (57°C) fixed-temperature heat detection
- Rate-of-rise detection at 20°F per minute or greater
- Rate-of-rise function active above 90°F
- Intelligent TrueSense optical and thermal analysis
- Onboard microprocessor
- Automatic sensitivity drift compensation
- Contamination monitoring
- Dirty-condition LED indication
- Magnetic functional testing
- Diagnostic LED pulse indications
- Compatible two-wire detector base
- Compatible four-wire detector base
- Optional auxiliary alarm relay
- Optional remote alarm LED
- 15–32 VDC operating voltage
- 100 µA standby current at 24 VDC
- 2.8%/ft nominal optical obscuration sensitivity
- 0–2,000 FPM air velocity range
- Low-profile frost-white housing
- Professional installation and testing required
LED Status Indicators
The detector includes a multifunction status LED.
During normal operation, the LED pulses approximately every four seconds.
Meanwhile, a steady illuminated LED indicates an alarm condition.
Additionally, the indicator provides diagnostic information during magnetic testing.
As a result, qualified technicians can identify normal, abnormal, and maintenance-related conditions.
Magnetic Functional Testing
The detector supports magnetic functional testing.
First, technicians position an approved test magnet at the designated location.
Next, the detector initiates its supported test sequence.
Additionally, the LED provides diagnostic pulse patterns when the sensing condition falls outside the normal compensation range.
For example, rapid pulses indicate an abnormally sensitive condition.
Meanwhile, slower pulses indicate reduced sensitivity.
Therefore, technicians can identify conditions requiring cleaning or additional service.
However, magnetic testing does not replace every required functional inspection.
Compatible Mounting Bases
The GSA4098-9602 supports several manufacturer-approved mounting bases.
For example, the 4098-9788 provides conventional two-wire operation and connections for a remote alarm indicator.
Additionally, the 4098-9682 supports four-wire operation with auxiliary alarm relay contacts.
Meanwhile, the 4098-9683 provides two-wire operation with an auxiliary alarm relay.
However, the 4098-9682 requires an external 24 VDC supply.
Furthermore, the 4098-9683 must be the only device connected to its initiating circuit to ensure relay operation.
Therefore, technicians must follow the manufacturer’s wiring requirements.
Electrical Operating Requirements
The detector operates from 15 to 32 VDC through the compatible initiating device circuit.
Additionally, its standby current is approximately 100 microamps at 24 VDC.
For two-wire operation, alarm current can reach 86 mA, depending on the circuit’s current-limiting characteristics.
Meanwhile, four-wire operation has a typical alarm current of 24 mA at 24 VDC.
Therefore, installers must verify the selected mounting base and fire alarm control panel ratings.
Environmental Operating Requirements
The detector has a general operating temperature range of 15°F to 100°F (-9°C to 38°C).
However, its UL-listed operating temperature range is 32°F to 100°F (0°C to 38°C).
Additionally, the manufacturer specifies an air velocity range of 0 to 2,000 feet per minute.
Furthermore, relative humidity may range from 10% to 95% under the specified conditions.
Therefore, installers should verify the environmental requirements before selecting a mounting location.
Typical Applications
The Simplex GSA4098-9602 supports compatible commercial and institutional fire alarm installations.
For example, typical applications may include offices, schools, hotels, healthcare facilities, warehouses, and retail properties.
Additionally, its combined optical and thermal sensing supports approved locations requiring multiple detection functions.
Furthermore, its conventional circuit design makes it relevant for maintaining compatible legacy Simplex systems.
However, technicians must confirm the applicable control panel compatibility before installation.
Installation and Compatibility
Before installation, verify the detector model, mounting base, initiating device circuit, and environmental conditions.
Next, inspect the housing, optical chamber, thermistor guard, and electrical contacts.
Additionally, confirm the correct wiring arrangement and any required auxiliary relay accessories.
Qualified technicians should install the detector according to Simplex instructions.
Afterward, they must verify alarm operation, thermal sensing, and applicable trouble or maintenance indications.
Therefore, the device should return to service only after the required testing is complete.
Maintenance and Replacement
Regular maintenance helps preserve dependable detector operation.
First, technicians should inspect the optical chamber for dust and debris.
Next, they should perform the approved magnetic and functional tests.
Additionally, they should review the LED diagnostic indications.
However, excessive contamination or abnormal sensitivity may require cleaning or replacement.
Consequently, technicians must confirm that the detector remains serviceable before returning it to the Simplex GSA4098-9602 combines optical sensing, fixed-temperature heat detection, rate-of-rise monitoring, and TrueSense analysis in one conventional detector.
Additionally, its automatic drift compensation and diagnostic LED support professional maintenance.
Therefore, this detector head is suitable for compatible Simplex installations when the mounting base, control panel, physical condition, and safety requirements have been verified.
GSA4098-9602 Datasheet
Shipping Services
We offer the following shipping services:
- USPS Priority Mail
- UPS Ground
If you would like your package shipped differently, please contact us.
Payment
We accept the following payment Card
American ExpressDiscoverDo not hesitate to contact us if you have any questions.
International Shipping
- If you are outside the United States and need our items you can contact us through an message.
- We offer 2 shipping options if they do not work, please contact us and we will make changes for you.
- We process all orders the same day when we receive the payment before 5:30 PM ET.
- Daily we strive to provide the best service to our buyers and give the highest satisfaction but if for some reason there is an error to receive your purchase please contact us before leaving a negative response.
Warranty
Please be aware that we are not authorized distributors. We can not guarantee the featured item will have the manufacturer\'s warranty or support.
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.