12" Patient Monitor ICU CCU Vital Sign for Hospital ECG NIBP RESP TEMP SPO2 PRT

12" Patient Monitor ICU CCU Vital Sign for Hospital ECG NIBP RESP TEMP SPO2 PRT
$354.32

Buy Now

12\" Patient Monitor ICU CCU Vital Sign For Hospital ECG NIBP RESP TEMP SPO2 PRFeatures:
1. Unique accessory management cabinet
2. 12.1-inch high resolution color TFT display
3. USB interfaces support easy software upgrade and data transfer
4. Three Working Modes: Monitoring, Surgery and Diagnosis
5. Simple and friendly operating display interface.
6. Multi-display modes suitable for different applications:
Standard Interface, Large font, ECG Standard Full Display, OXY, Trend Table, BP Trend.
7. Built-in high-capacity battery for up to 3 hours of continuous workStandard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PRTechnique Specifications:
ECG
1. Lead Mode: 5 Leads (I, II, III, AVR, AVL, AVF, V)
2. Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
3. Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
① Resolution: 1 BPM
② Accuracy: ±1%
③ Sensitivity >200 uV(Peak to peak)
4. ST measurement range: -2.0 ~ +2.0 mV
① Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified
5. Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
6. Bandwidth:
7. Diagnostic: 0.05~130 Hz
8. Monitor: 0.5~40 Hz
9. Surgery: 1~20 HzSPO2
1. Measuring Range: 0 ~ 100 %
2. Resolution: 1%
3. Accuracy: 70% ~ 100% (±2 %)
4. Pulse Rate: 20-250 BPM
5. Resolution: 1 BPM
6. Accuracy: 3 BPMNIBP
1. Method: Oscillometry
2. Measure mode: Manual, Auto, STAT
3. Unit: mmHg, kPa
4. Measure and alarm range:
5.1 Adult Mode
① SYS 40 ~ 280 mmHg
② DIA 10 ~ 225 mmHg
③ MEAN 20 ~ 240 mmHg
5.2 Pediatric Mode
① SYS 40 ~ 220 mmHg
② DIA 10 ~ 160 mmHg
③ MEAN 20 ~ 170 mmHg
5.3 Neonatal Mode
① SYS 40 ~ 135 mmHg
② DIA 10 ~ 100 mmHg
③ MEAN 20 ~ 110 mmHg
6. Resolution: 1mmHg
7. Accuracy: 5mmHgRESP
1. Method: Impedance between RA-LL or RALA
2. Measurement Range:
① Adult: 10 ~ 120 BrPM
② Neonatal / Pediatric: 7 ~ 150 BrPM
3. Resolution: 1 BrPM
4. Accuracy: 2 BrPMTEMP
1. Measure and Alarm Range: 0 ~ 50℃
2. Resolution: 0.1℃
3. Accuracy: 0.1℃Standard Configurations:
Main Unit *1
5-lead ECG Cable *1
Disposable ECG Electrode *5
Adult Spo2 Probe *1
Adult NIBP Cuff *1
NIBP Extension Tube *1
Temperature Probe *1
Power Cable *1
User Manual *1
Fuse Patient Monitor ICU CCU Vital Sign For Hospital ECG NIBP RESP TEMP SPO2 PRFeatures:
1. 12.1\" TFT color LCD,800*600dpi
2. Standard 6 para: ECG, SpO2, NIBP, TEMP, RESP, PR
3. Fanless design, quiet, energy-saving and clean
4. With the standard interface, OxyCRG, trend chard, big character interface and view bed,
5. Operation mode: keys and buttons.
6. Display up to 8-channel waveform on one screen.
7. NIBP measurement mode: Manual/AUTO/Continuous, storage for 1000-group NlBP data
8. Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
9. AC/DC, built-in rechargeable lithium battery achieves uninterrupted monitoring.

Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR

Technique Specifications:
ECG
1. Lead Mode: 5 Leads (I, II, III, AVR, AVL, AVF, V)
2. Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
3. Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
① Resolution: 1 BPM
② Accuracy: ±1%
③ Sensitivity >200 uV(Peak to peak)
4. ST measurement range: -2.0 ~ +2.0 mV
① Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified
5. Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
6. Diagnostic: 0.05~130 Hz
7. Monitor: 0.5~40 Hz
8. Surgery: 1~20 Hz

SPO2
1. Measuring Range:35%~100%
2. Resolution: 1%
3. Certainty of measurement: In the range of 70% to 100%, the precision should be ± 3%
4. Pulse Rate: 20-250 BPM
5. Resolution ratio: 1 BPM
6. Accuracy: 2 BPM

NIBP
1. Method: Pulse wave oscillation method
2. Measure mode: Manual / Automatic / Continuous
3. Unit: mmHg, kPa
4. Measure and alarm range:
5.1 Adult Mode
① SYS 30 ~ 255 mmHg
② DIA 10 ~ 220 mmHg
③ MEAN 20 ~ 235 mmHg
5.2 Pediatric Mode
① SYS 30 ~ 255 mmHg
② DIA 10 ~ 220 mmHg
③ MEAN 20 ~ 235 mmHg
5.3 Neonatal Mode
① SYS 30 ~ 135 mmHg
② DIA 10 ~ 110 mmHg
③ MEAN 20 ~ 125 mmHg
6. Resolution ratio: 1mmHg
7. Accuracy: 5mmHg

RESP
1. Method: Impedance between RA-LL or RALA
2. Measurement Range:
① Adult: 0 ~ 120 BrPM
② Neonatal / Pediatric: 0 ~ 150 BrPM
3. Resolution ratio: 1 BrPM
4. Accuracy: 2 BrPM

TEMP
1. Measure and Alarm Range: 0 ~ 50℃
2. Resolution ratio: 0.1℃
3. Certainty of measurement: ± 0.1℃ (without probe error)

Standard Configurations:
Patient Monitor *1
Power Cord *1
Spo2 Sensor *1
Temp Sensor *1
5-lead ECG Cable *1
Electrodes *10
NIBP Cuff *1
NIBP Extension Hose *1
User Manual *1
Ground Line Patient Monitor ICU CCU Vital Sign For Hospital ECG NIBP RESP TEMP SPO2 PRStandard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR

Features:
1.15.6 inch large screen for viewing convenience.
2.Three Working Modes: Monitoring, Surgery and Diagnosis.
3.Simple and friendly operating display interface.
4.Multi-display modes suitable for different applications: Standard Interface, Large font, ECG Standard Full Display, OXY , Trend Table, BP Trend.
5.Built-in high capacity battery up to 3 hours of continuous work.
6.VGA output for external display.

Technique Specification:
ECG
1.Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V)
2.Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
3.Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
①Resolution: 1 BPM
②Accuracy: ±1%
③Sensitivity >200 uV(Peak to peak)
4.ST measurement range: -2.0 ~ +2.0 mV
①Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
②Other Range: unspecified
5.Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
6.Bandwidth:
①Diagnostic: 0.05~130 Hz
②Monitor: 0.5~40 Hz
③Surgery: 1~20 Hz

SPO2
1.Measuring Range: 0 ~ 100 %
2.Resolution: 1%
3.Accuracy: 70% ~ 100% (2 %)
4.Pulse Rate: 20-250 BPM
5.Resolution: 1 BPM
6.Accuracy: 3 BPM

NIBP
1.Method: Oscillometry
2.Measure mode: Manual, Auto, STAT
3.Unit: mmHg, kPa
4.Measure and alarm range:
4.1Adult Mode
①SYS 40 ~ 280 mmHg
②DIA 10 ~ 225 mmHg
③MEAN 20 ~ 240 mmHg
4.2Pediatric Mode
①SYS 40 ~ 220 mmHg
②DIA 10 ~ 160 mmHg
③MEAN 20 ~ 170 mmHg
4.3Neonatal Mode
①SYS 40 ~ 135 mmHg
②DIA 10 ~ 100 mmHg
③MEAN 20 ~ 110 mmHg
5.Resolution: 1mmHg
6.Accuracy: 5mmHg

RESP
1.Method: Impedance between RA-LL or RALA
2.Measurement Range:
①Adult: 10 ~ 120 BrPM
②Neonatal / Pediatric: 7 ~ 150 BrPM
3.Resolution: 1 BrPM
4.Accuracy: 2 BrPM

TEMP
1.Measure and Alarm Range: 0 ~ 50 C
2.Resolution: 0.1C
3.Accuracy: 0.1C

Standard Configuration:
1.Main Unit *1
2.5-lead ECG cable *1
3.Disposable ECG Electrode *5
4.Adult Spo2 probe *1
5.Adult NIBP cuff *1
6.NIBP extension tube *1
7.Temperature probe *1
8.Power Cable *1
9.User Manual *1
10.Fuse inch patient monitor with ETCO2 (No additional purchase required)

Features:
1.Unique accessory management cabinet.
2.12.1 inch high resolution color TFT display.
3.Includes a ETCO2 sensor module; no additional purchase required.
4.Three Working Modes: Monitoring, Surgery and Diagnosis.
5.Simple and friendly operating display interface.
6.Multi-display modes suitable for different applications:
Standard Interface, Large font, ECG Standard Full Display, OXY , Trend Table, BP Trend.
7.Built-in high capacity battery up to 3 hours of continuous work

Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR, ETCO2

Technique Specification:
ETCO2
1.Monitoring range: 0% ~ 13%
2.Resolution: 1 mmHg
3.Accuracy: 2 mmHg @ < 5.0% CO₂ (at ATPS)
4.Respiration Rate: 3 - 150 bpm

ECG
1.Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V)
2.Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
3.Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
① Resolution: 1 BPM
② Accuracy: ±1%
③ Sensitivity >200 uV(Peak to peak)
4.ST measurement range: -2.0 ~ +2.0 mV
① Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified
5.Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
6.Bandwidth:
7.Diagnostic: 0.05~130 Hz
8.Monitor: 0.5~40 Hz
9.Surgery: 1~20 Hz

SPO2
1.Measuring Range: 0 ~ 100 %
2.Resolution: 1%
3.Accuracy: 70% ~ 100% (±2 %)
4.Pulse Rate: 20-250 BPM
5.Resolution: 1 BPM
6.Accuracy: 3 BPM

NIBP
1.Method: Oscillometry
2.Measure mode: Manual, Auto, STAT
3.Unit: mmHg, kPa
4.Measure and alarm range:
5.1 Adult Mode
① SYS: 40 ~ 280 mmHg
② DIA: 10 ~ 225 mmHg
③ MEAN: 20 ~ 240 mmHg
5.2 Pediatric Mode
① SYS: 40 ~ 220 mmHg
② DIA: 10 ~ 160 mmHg
③ MEAN: 20 ~ 170 mmHg
5.3 Neonatal Mode
① SYS: 40 ~ 135 mmHg
② DIA: 10 ~ 100 mmHg
③ MEAN: 20 ~ 110 mmHg
6.Resolution: 1mmHg
7.Accuracy: 5mmHg

RESP
1.Method: Impedance between RA-LL or RALA
2.Measurement Range:
① Adult: 10 ~ 120 BrPM
② Neonatal / Pediatric: 7 ~ 150 BrPM
3.Resolution: 1 BrPM
4.Accuracy: 2 BrPM

TEMP
1.Measure and Alarm Range: 0 ~ 50℃
2.Resolution: 0.1℃
3.Accuracy: 0.1℃

Standard Configuration:
Main Unit *1
ETCO2 Sensor *1
5-lead ECG cable *1
Disposable ECG Electrode *5
Adult Spo2 probe *1
Adult NIBP cuff *1
NIBP extension tube *1
Temperature probe *1
Power Cable *1
User Manual *1
Fuse style=\"color: rgb(0, 0, 0); font-family: "Market Sans", Arial, sans-serif; font-size: medium; white-space: normal; line-height: 1.5;\">12\" Modular Patient Monitor Vital Sign, Optional modules: EtCO2 and IBP

Features:
1.Optional EtCO2 and IBP extension modules offer convenient, plug-and-play upgrades.
2.12.1 inch high resolution color TFT display.
3.Simple and friendly operating display interface.
4.Multi-display modes suitable for different applications:
Standard Interface, Large font, ECG Standard Full Display, OXY , Trend Table, BP Trend.
5.Built-in high capacity battery up to 3 hours of continuous work.

Includes ECG, NIBP, SpO2, TEMP, RESP, EtCO2, and PR functions.
Optional modules available: EtCO2 and IBP.

Technique Specification:
ECG
1.Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V)
2.Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
3.Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
① Resolution: 1 BPM
② Accuracy: ±1%
③ Sensitivity >200 uV(Peak to peak)
4.ST measurement range: -2.0 ~ +2.0 mV
① Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified
5.Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
6.Bandwidth:
7.Diagnostic: 0.05~130 Hz
8.Monitor: 0.5~40 Hz
9.Surgery: 1~20 Hz

SPO2
1.Measuring Range: 0 ~ 100 %
2.Resolution: 1%
3.Accuracy: 70% ~ 100% (±2 %)
4.Pulse Rate: 20-250 BPM
5.Resolution: 1 BPM
6.Accuracy: 3 BPM

NIBP
1.Method: Oscillometry
2.Measure mode: Manual, Auto, STAT
3.Unit: mmHg, kPa
4.Measure and alarm range:
5.1 Adult Mode
① SYS 40 ~ 280 mmHg
② DIA 10 ~ 225 mmHg
③ MEAN 20 ~ 240 mmHg
5.2 Pediatric Mode
① SYS 40 ~ 220 mmHg
② DIA 10 ~ 160 mmHg
③ MEAN 20 ~ 170 mmHg
5.3 Neonatal Mode
① SYS 40 ~ 135 mmHg
② DIA 10 ~ 100 mmHg
③ MEAN 20 ~ 110 mmHg
6.Resolution: 1mmHg
7.Accuracy: 5mmHg

RESP
1.Method: Impedance between RA-LL or RALA
2.Measurement Range:
① Adult: 10 ~ 120 BrPM
② Neonatal / Pediatric: 7 ~ 150 BrPM
3.Resolution: 1 BrPM
4.Accuracy: 2 BrPM

TEMP
1.Measure and Alarm Range: 0 ~ 50℃
2.Resolution: 0.1℃
3.Accuracy: 0.1℃

Standard Configuration:
Main Unit *1
5-lead ECG cable *1
Disposable ECG Electrode *5
Adult Spo2 probe *1
Adult NIBP cuff *1
NIBP extension tube *1
Temperature probe *1
Power Cable *1
User Manual *1
Fuse *3

12\" Patient Monitor For Hospital ECG NIBP RESP TEMP SPO2 PR with Thermal Printer

Features:
1.The built-in thermal printer allows convenient, on-demand printing of ECG waveforms.
2.12.1\"TFT color LCD,800*600dpi
3.Standard 6 para: ECG, SpO2, NIBP, TEMP, RESP, PR
4.Fanless design, quiet, energy-saving and clean
5.With standard interface, OxyCRG, trend chard, big character interface and view bed,
6.Operation mode: kevs and buttons.
7.Display up to 8-channel waveform on one screen.
8.NIBP measurement mode: Manual/AUTO/Continuous, storage for 1000-group NlBP data
9.Review for 71 alarm events of all parameters and 60 arrhythmia alarm events.
10.AC/DC, built-in rechargeable lithium battery achieve uninterrupted monitoring.

Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR

Technique Specification:
ECG
1.Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V)
2.Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
3.Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
① Resolution: 1 BPM
② Accuracy: ±1%
③ Sensitivity >200 uV(Peak to peak)
4.ST measurement range: -2.0 ~ +2.0 mV
① Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified
5.Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
6.Bandwidth:
7.Diagnostic: 0.05~130 Hz
8.Monitor: 0.5~40 Hz
9.Surgery: 1~20 Hz

SPO2
1.Measuring Range:35%~100%
2.Resolution: 1%
3.Certainty of measurement: In the range of 70% to 100%, the precision should be ± 3%
4.Pulse Rate: 20-250 BPM
5.Resolution ratio: 1 BPM
6.Accuracy: 2 BPM

NIBP
1.Method: Pulse wave oscillation method
2.Measure mode: Manual / Automatic / Continuous
3.Unit: mmHg, kPa
4.Measure and alarm range:
5.1 Adult Mode
① SYS 30 ~ 255 mmHg
② DIA 10 ~ 220 mmHg
③ MEAN 20 ~ 235 mmHg
5.2 Pediatric Mode
① SYS 30 ~ 255 mmHg
② DIA 10 ~ 220 mmHg
③ MEAN 20 ~ 235 mmHg
5.3 Neonatal Mode
① SYS 30 ~ 135 mmHg
② DIA 10 ~ 110 mmHg
③ MEAN 20 ~ 125 mmHg
6.Resolution ratio: 1mmHg
7.Accuracy: 5mmHg

RESP
1.Method: Impedance between RA-LL or RALA
2.Measurement Range:
① Adult: 0 ~ 120 BrPM
② Neonatal / Pediatric: 0 ~ 150 BrPM
3.Resolution ratio: 1 BrPM
4.Accuracy: 2 BrPM

TEMP
1.Measure and Alarm Range: 0 ~ 50℃
2.Resolution ratio: 0.1℃
3.Certainty of measurement: ± 0.1℃ (without probe error)

Standard Configuration:
Patient Monitor *1
Power Cord *1
Spo2 sensor *1
Temp sensor *1
5-lead ECG cable *1
Electrodes *10
NIBP cuff *1
NIBP Extension Hose *1
User Manual *1
Ground Line *1
Thermal printing paper *1

Mobile Rolling Cart for patient monitor Medical Trolley Cart with Basket 90*55mm X-3
Medical Trolley Cart for Patient Monitor

The Medical Trolley Cart is suitable for Patient Monitor and is ideal for operating rooms, recovery rooms and intensive care. This allows the most important parameters and vital data to be viewed at a glance. The corresponding patient monitor can be easily mounted on the bracket and thanks.
Product Dimensions:
Screw Hole Spacing: 90 x 55mm
Product Feature:
1.Premium Construction: Crafted from robust aluminum alloy, this Medical Trolley cart combines lightweight construction with.
2Height adjustable: The height of the patient monitor trolley is adjustable to accommodate different usage scenarios.
3.Quick-release design allows for quick removal of the fixed monitor.
4.Storage Basket: the Medical Cart Comes with a Storage Basket for Storing Small Tools or Items, Which Saves Space and Provides Convenience.
5.Effortless Mobility: Equipped with five 360° casters, including two with foot brakes, this rolling cart provides smooth and effortless mobility. Easily transport tools or items between locations without any hassle.
6.Affordable prices, get the best experience at the lowest price.
7.Stylish Appearance: the Pure White Exterior Combines with the Smooth Lines of the Trolley Cart, Giving It an Extraordinary Appearance and Allowing It to Be Matched with a Wide Range of Instruments.
FDAStatement:
Thanksforyourunderstanding!

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design