|
>> If you dont know how to design a userbar, then write here a Userbar that you want.
>> If you know how to design them help these people and design what they request.
|
 |
 |
USERBARS.org | Free Forum Userbars
| On eBay now |
12" Multiparameter Patient Monitor Vital Signs ECG,NIBP,RESP,TEMP,SPO2,PR,ETCO2
$879.45

12 inch patient monitor with ETCO2 (No additional purchase accessory management cabinet. 2.12.1 inch high resolution color TFT display. 3.Includes a ETCO2 sensor module; no additional purchase required. 4.Three Working Modes: Monitoring, Surgery and Diagnosis. 5.Simple and friendly operating display interface. 6.Multi-display modes suitable for different applications: Standard Interface, Large font, ECG Standard Full Display, OXY , Trend Table, BP Trend. 7.Built-in high capacity battery up to 3 hours of continuous workStandard Parameters: ECG, RESP, TEMP, NIBP, SPO2, PR, ETCO2Technique range: 0% ~ 13% 2.Resolution: 1 mmHg 3.Accuracy: 2 mmHg @ < 5.0% CO₂ (at ATPS) 4.Respiration Rate: 3 - 150 bpmECG 1.Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V) 2.Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV 3.Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal) ① Resolution: 1 BPM ② Accuracy: ±1% ③ Sensitivity >200 uV(Peak to peak) 4.ST measurement range: -2.0 ~ +2.0 mV ① Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater Other Range: unspecified 5.Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s 6.Bandwidth: 7.Diagnostic: 0.05~130 Hz 8.Monitor: 0.5~40 Hz 9.Surgery: 1~20 HzSPO2 1.Measuring Range: 0 ~ 100 % 2.Resolution: 1% 3.Accuracy: 70% ~ 100% (±2 %) 4.Pulse Rate: 20-250 BPM 5.Resolution: 1 BPM 6.Accuracy: 3 BPMNIBP 1.Method: Oscillometry 2.Measure mode: Manual, Auto, STAT 3.Unit: mmHg, kPa 4.Measure and alarm range: 5.1 Adult Mode ① SYS: 40 ~ 280 mmHg ② DIA: 10 ~ 225 mmHg ③ MEAN: 20 ~ 240 mmHg 5.2 Pediatric Mode ① SYS: 40 ~ 220 mmHg ② DIA: 10 ~ 160 mmHg ③ MEAN: 20 ~ 170 mmHg 5.3 Neonatal Mode ① SYS: 40 ~ 135 mmHg ② DIA: 10 ~ 100 mmHg ③ MEAN: 20 ~ 110 mmHg 6.Resolution: 1mmHg 7.Accuracy: 5mmHgRESP 1.Method: Impedance between RA-LL or RALA 2.Measurement Range: ① Adult: 10 ~ 120 BrPM ② Neonatal / Pediatric: 7 ~ 150 BrPM 3.Resolution: 1 BrPM 4.Accuracy: 2 BrPMTEMP 1.Measure and Alarm Range: 0 ~ 50℃ 2.Resolution: 0.1℃ 3.Accuracy: 0.1℃Standard Configuration: Main Unit *1 ETCO2 Sensor *1 5-lead ECG cable *1 Disposable ECG Electrode *5 Adult Spo2 probe *1 Adult NIBP cuff *1 NIBP extension tube *1 Temperature probe *1 Power Cable *1 User Manual *1 Fuse *3FDAStatement: Thanksforyourunderstanding!

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
|
|
|
 |
 |
|