|
>> If you dont know how to design a userbar, then write here a Userbar that you want.
>> If you know how to design them help these people and design what they request.
|
 |
 |
USERBARS.org | Free Forum Userbars
| On eBay now |
ifm PI2898 Pressure Sensor w/ Display
$599.00

Flush pressure sensor with display. Robust stainless steel housing for use in the food and beverage industry. Hygienic, flush design. Resistant to high-pressure cleaning with aggressive cleaning agents. High temperature resistance and high protection rating. Programmable analog and switching output. Product characteristicsNumber of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1Measuring range-0.0124...0.25 bar-12.4...250 mbar-5...100.4 inH2O-1.24...25 kPaProcess connectionthreaded connection G 1 external thread sealing cone - 27 mm; Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.ApplicationSpecial featuregold-plated contactsApplicationflush mountable for the food and beverage industryMediaviscous media and liquids with suspended particles; liquids and gasesMedium temperature[°C]-25...125; (145 max. 1h)Min. burst pressure30000 mbar12044 inH2O3000 kPaPressure rating6000 mbar2400 inH2O600 kPaVacuum resistance-1000 mbar-0.1 MPaType of pressurerelative pressureMAWP (for applications according to CRN)[bar]10Electrical dataMin. insulation resistance[MΩ]100; (500 V DC)Protection classIIIReverse polarity protectionyesIntegrated watchdogyes2-wireOperating voltage[V]20...32 DCCurrent consumption[mA]3.6...21Power-on delay time[s]13-wireOperating voltage[V]18...32 DCCurrent consumption[mA]< 45Power-on delay time[s]0.5Inputs / outputsNumber of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1OutputsTotal number of outputs2Output signalswitching signal; analog signal; IO-Link; (configurable)Electrical designPNP/NPNNumber of digital outputs2Output functionnormally open / closed; (configurable)Number of analog outputs1Analog current output[mA]4...20, invertible; (scalable)Short-circuit protectionyesType of short-circuit protectionyes (non-latching)Overload protectionyes2-wireMax. load[Ω]3003-wireMax. voltage drop switching output DC[V]2Permanent current rating of switching output DC[mA]250Switching frequency DC[Hz]125Max. load[Ω](Ub - 10 V) / 20 mAMeasuring/setting rangeMeasuring range-0.0124...0.25 bar-12.4...250 mbar-5...100.4 inH2O-1.24...25 kPaSet point SP-12...250 mbar-4.8...100.4 inH2O-1.2...25 kPaReset point rP-12.4...249.6 mbar-5...100.2 inH2O-1.24...24.96 kPaAnalog start point-12.4...187.4 mbar-5...75.2 inH2O-1.24...18.74 kPaAnalog end point50...250 mbar20.1...100.4 inH2O5...25 kPaIn steps of0.2 mbar0.1 inH2O0.02 kPaFactory settingSP1 = 62.4 mbarrP1 = 57.4 mbarSP2 = 187.4 mbarrP2 = 182.4 mbarASP = 0.0 mbarAEP = 250.0 mbardAP = 0.06 sdAA = 0.03 sAccuracy / deviationsSwitch point accuracy[% of the span]< ± 0,2; (Turn down 1:1)Repeatability[% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)Characteristics deviation[% of the span]< ± 0,2; (Turn down 1:1 , linearity, incl. hysteresis and repeatability , limit value setting to DIN EN IEC 62828-1)Linearity deviation[% of the span]< ± 0,15; (Turn down 1:1)Hysteresis deviation[% of the span]< ± 0,15; (Turn down 1:1)Long-term stability[% of the span]< ± 0,1; (Turn down 1:1; per year)Temperature coefficient zero point[% of the span / 10 K]< ± 0,05; (0...70 °C)Temperature coefficient span[% of the span / 10 K]< ± 0,15; (0...70 °C)Reaction timesDamping process value dAP[s]0...30Damping for the analog output dAA[s]0.01...99.992-wireStep response time analog output[ms]453-wireMin. response time of switching output (dAP)[ms]3Step response time analog output[ms]7InterfacesCommunication interfaceIO-LinkTransmission typeCOM2 (38,4 kBaud)IO-Link revision1.0SIO modeyesRequired master port classAProcess data analog1Process data binary2Min. process cycle time[ms]2.3Supported DeviceIDsType of operationDeviceIDdefault257Operating conditionsAmbient temperature[°C]-25...80Storage temperature[°C]-40...100ProtectionIP 67; IP 68; IP 69KTests / approvalsEMCEN 61000-4-2 ESD4 kV CD / 8 kV ADEN 61000-4-3 HF radiated10 V/mEN 61000-4-4 Burst2 kVEN 61000-4-5 Surge0,5/1 kVEN 61000-4-6 HF conducted10 VShock resistanceDIN IEC 68-2-2750 g (11 ms)Vibration resistanceDIN IEC 68-2-620 g (10...2000 Hz)MTTF[years]149Mechanical 50 / L = 106Materialstainless steel (1.4404 / 316L); FKM; PTFE; PBT; PEI; PFAMaterials (wetted parts)ceramics (99.9 % Al2O3); stainless steel (1.4435 / 316L) surface characteristics: Ra < 0,4 µm / Rz = 4 µm; PTFEMin. pressure cycles100 millionProcess connectionthreaded connection G 1 external thread sealing cone - 27 mm; Attention: The unit must only be installed in a process connection for G1 sealing cone.; The G1A sealing cone of the unit is only suited for adapters with metal end stop.Displays / operating elementsDisplayDisplay unitLED, greenSwitching statusLED, yellowFunction displayalphanumeric display, 4-digitMeasured valuesalphanumeric display, 4-digitDisplay unitmbar; kPa; inH2O; mmWS; % of the spanRemarksPack quantity1 pcs.Electrical connectionConnector1 x M12; coding: A; Contacts: 4, gold-plated

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
|
|
|
 |
 |
|