X20SLX811 | B&R Industrial Automation

X20SLX811 | B&R Industrial Automation
$962.43

Buy Now

B&R X20SLX811 New Rev. D0 VAT:
VAT is not included
Buyers from the Netherlands and private buyers from EU, have to pay 21% VAT, please contact us before purchasing, so we can provide you the invoice
Commercial buyers from EU (NO VAT) will be asked to provide us their VAT number.
Buyer from outside the EU (NO VAT).
DescriptionMaterial number:

X20SLX811

Description:
  • openSAFETY manager for up to 10 SafeNODEs
  • Flexibly programmable using Automation Studio / SafeDESIGNER
  • Innovative management of safe machine options (SafeOPTION)
  • Parameter and configuration management
  • 8 safe digital inputs
  • 4 pulse outputs
  • Sink circuit
  • Software input filter configurable for each channel

The module is equipped with SafeLOGIC functionality that allows it to safely execute applications designed in SafeDESIGNER. The module can be used in safety-related applications up to PL e or SIL 3.

In addition, the module coordinates the safety-related communication of all modules involved in the application. In this context, the module also monitors the configuration of these modules and carries out autonomous parameter downloads to the modules whenever necessary. This guarantees a consistent and correct module configuration in the network from a safety standpoint in all scenarios involving module replacement and service. These services are performed in conjunction with Automation Runtime on the standard CPU.

In addition, SafeLOGIC-X products have the same I/O properties as the associated SafeIO products (X20SIx1x0).

SpecificationShort description I/O module 8 safe type A digital inputs, 4 pulse outputs, 24 VDC, SafeLOGIC-X technology General information B&R ID code 0xE757 System requirements Automation Studio 4.0 or later Automation Runtime B4.25 or later SafeDESIGNER 4.2.0 or later Safety Release 1.10 or later mapp Technology Package mapp Safety 5.7.0 or later Status indicators I/O function per channel, operating state, module status Diagnostics Module run/error Yes, using LED status indicator and software Inputs Yes, using LED status indicator and software Max. I/O cycle time 1 ms Power consumption Bus 0.4 W Internal I/O 2.5 W Additional power dissipation caused by actuators (resistive) [W] 0.8 Electrical isolation Channel - Bus Yes Channel - Channel No Certifications CE Yes UKCA Yes Functional safety cULus FSPC E361559
Energy and industrial systems
Certified for functional safety
ANSI UL 1998:2013 Functional safety IEC 61508:2010, SIL 3
EN 62061:2005/A2:2015, SIL 3
EN ISO 13849-1:2015, Cat. 4 / PL e
IEC 61511:2004, SIL 3 Functional safety EN 50156-1:2004 ATEX Zone 2, II 3G Ex nA nC IIA T5 Gc
IP20, Ta (see X20 user's manual)
FTZÚ 09 ATEX 0083X UL cULus E115267
Industrial control equipment DNV In preparation EAC Yes Safety characteristics EN ISO 13849-1:2015 Category Cat. 3 when using individual input channels,
Cat. 4 when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels PL PL e DC >94% Mission time Max. 20 years IEC 61508:2010,
IEC 61511:2004,
EN 62061:2013 SIL CL SIL 3 SFF >90% PFH / PFHd openSAFETY wired Negligible openSAFETY wireless <1*10-14 * Number of openSAFETY packets per hour Proof test interval (PT) 20 years Safe digital inputs EN ISO 13849-1:2015 MTTFD per channel 100 years when using individual input channels,
2500 years when using input channel pairs (e.g. SI1 and SI2) or more than 2 input channels IEC 61508:2010,
IEC 61511:2004,
EN 62061:2013 PFH / PFHd per channel <1*10-10 PFD per channel <2*10-5 Functionality Communication with each other Communication only possible with SafeLOGIC controller X20(c)SL81xx
Max. 1 active SafeLOGIC-X controller per standard CPU (e.g. X20(c)CPxxxx) Support for Safe Commissioning Options BOOL 64 INT 16 UINT 16 DINT 16 UDINT 16 SafeMOTION support Yes Max. number of SafeMOTION axes 6, depends on the data width of the modules used Timing precision Time * 0.05 + Cycle time of the safety application Shortest task class cycle time 2 ms Max. number of SafeNODEs 10, depends on the data width of the modules used Data exchange between CPU and SafeLOGIC controller Max. total data width for each direction 16 bytes Max. number of data points for each direction BOOL 96 INT 8 UINT 8 DINT 4 UDINT 4 Data exchange between SafeDOMAIN and SafeDOMAIN Use as Managing SafeDOMAIN Yes, starting with mapp Safety 5.10.0 and hardware upgrade 2.2.1.0 Use as Connected SafeDOMAIN Yes, starting with mapp Safety 5.13.0, hardware upgrade 2.4.0.0 and Automation Runtime A4.90 Max. total data width for each direction 8 bytes Max. total number of data points for each direction 4 Max. number of data points for each direction BOOL 16 INT 2 UINT 2 DINT 2 UDINT 2 Max. number of linked Managing SafeDOMAINs 0,
starting with mapp Safety 5.13.0, hardware upgrade 2.4.0.0 and Automation Runtime A4.90: 1 Limit values for SafeDESIGNER application Max. resources available for SafeDESIGNER info window entries FB instances 256 Marker memory 5120 bytes (0x1400) Stack memory 4096 bytes Memory for safe input data 128 bytes, 68 bytes of which are usable for modules Memory for safe output data 64 bytes Memory for standard input data 64 bytes Memory for standard output data 64 bytes Marker count 256 Additional SafeDESIGNER limit values Max. number of function block types 64 Max. number of force variables 8 Max. number of variable with variable status 128 I/O power supply Nominal voltage 24 VDC Voltage range 24 VDC -15% / +20% Integrated protection Reverse polarity protection Safe digital inputs Quantity 8 Variant Type A Nominal voltage 24 VDC Input characteristics per EN 61131-2 Type 1 Input filter Hardware ≤150 µs Software Configurable between 0 and 500 ms Input circuit Sink Input voltage 24 VDC -15% / +20% Input current at 24 VDC Min. 2 mA to max. 3.28 mA Input resistance Min. 7.33 kΩ Error detection time 100 ms Insulation voltage between channel and bus 500 Veff Switching threshold Low <5 VDC High >15 VDC Line length between signal source (pulse output or external signal) and input Max. 60 m with unshielded line
Max. 400 m with shielded line Pulse outputs Quantity 4 Variant Push-Pull Nominal output current 50 mA Output protection Shutdown of individual channels in the event of overload or short circuit Peak short-circuit current 0.5 A for 120 µs Short-circuit current 15 mAeff Leakage current when the output is switched off 0.1 mA RDS(on) 80 Ω Switching voltage I/O power supply minus voltage drop due to RDS(on) Total nominal current 200 mA Operating conditions Mounting orientation Horizontal Yes Vertical Yes Installation elevation above sea level 0 to 2000 m, no limitation Degree of protection per EN 60529 IP20 Ambient conditions Temperature Operation Horizontal mounting orientation 0 to 60°C Vertical mounting orientation 0 to 50°C Derating See section "Derating". Storage -40 to 85°C Transport -40 to 85°C Relative humidity Operation 5 to 95%, non-condensing Storage 5 to 95%, non-condensing Transport 5 to 95%, non-condensing Mechanical properties Note Order 1x safety-keyed terminal block separately.
Order 1x safety-keyed bus module (single-width) separately. Pitch 12.5+0.2 mm