The multimode R164061 and single-mode R164062 accessory kits allow one-jumper calibration when testing cabling systems with LC connectors. The kits utilize a precision LC adapter for the receive (Rx) port of each FiberTEK III module and a SC-LC test cord for the transmit (Tx) port. One-jumper calibration recommended by most standards for field testing. Procedure is the same for MM and SM testing.
One-jumper Calibration
- Choose desired test standard in LanTEK.
- Collect 2 x LC-SC and 2 x LC-LC test cords. Clean and inspect each connector.
- Attach LC end to Rx port and SC end to Tx port of each module.
- Select Field Calibration from home screen.
- Press 1 Jumper (F2) calibration mode.
- Press Start (F1) icon to begin.
Bi-directional Test Step 1
- Disconnect test cord from Rx port of each module. Do not disturb connector at Tx port.
- Attach an LC-LC test cord to the Rx port of each module.
- Connect test cords to cable under test after cleaning the connectors of cable under test.
- Run Autotest.
Measured loss includes the connection at the end of the test cords, the cord on the Rx port and the cable under test.
Bi-directional Test Step 2
- Reverse the test cord connections at both ends of the cable under test.
- Do not remove the connections to the FiberTEK III adapters, this will void the calibration.
- Press Continue (F1) to resume the test. The results for both fibers in each direction will be displayed at test completion.
- R164053- Cable kit SC/PC MM 50/125µm
- R164054- Cable kit FC/PC MM 50/125µm
- R164055- Cable kit ST/PC MM 50/125µm
- R164056- LC 50/125µm cables and couplers
- R164057- Cable kit SC/PC SM 9/125µm
- R164058- Cable kit FC/PC SM 9/125µm
- R164059- LC 9/125µm cables and couplers
- R164061- Cable and adapter kit LC MM 50/125µm
- R164062- Cable and adapter kit LC SM 9/125µm
- R164064- LC Rx adapter for MM and SM, each
In The Box
- (6) 50/125um LC - LC Cable
- (6) 50/125um LC - SC Cable
- (4) LC - LC Coupler
- (2) LC Receiver Adapter Photodiode with Boot