FMIwas established to offer consumers the opportunity to benefit from incredible deals on: new, over-stocked, open-box, and refurbished products from all major retailers and manufacturers. Every single item we sell goes through thorough inspection processes to make certain it works perfectly. FMI’s team ensure they are functional, according to the original manufacture\'s specifications.
Each item comes exactly as pictured unless there are more than one quantity. Then you will receive an item ofsimilarcondition.If any item is not shown in the picture, it will not be included unless stated in the description.
For any inquiry or issue,PLEASEcontact us before leaving response or opening a case. We will try our best to resolve any issue. We at FMI stride to satisfy our customer needs. Most importantly, we value your business and ensure you received the best experience.Thank You!
[ TRACO Power TPP 40‑148E‑D, Medical‑Grade AC/DC PCB‑Mount Power Module]
ABOUT THIS ITEM
**[ C9 - New Open Box - F4 -Hardware Functional]**
UI:[ V004351]
**[ New – Open box]**
INCLUDES: [POWER SUPPLY]
FEATURED DESCRIPTION:
The TRACO Power TPP 40‑148E‑D is a 40 W, 48 VDC, medical‑grade AC/DC PCB‑mount power module with 4000 VAC reinforced isolation, <100 µA leakage, 93% efficiency, and a –40 °C to +80 °C operating range.
⚡ Core Electrical Specifications
Output voltage: 48 VDC (adjustable 43.2–52.8 VDC)
Output current: 840 mA max (single‑output)
Output power: 40 W continuous
Efficiency: 93% typ. (highest in the TPP 40E‑D family)
Ripple & noise: 150 mVp‑p typ / 200 mVp‑p max (20 MHz BW)
Voltage set accuracy: ±1% max
Adjustment range: ±10% via external trim resistor
🔌 Input Specifications
AC input range: 85–264 VAC (full range)
DC input range: 120–370 VDC (functional, not safety‑certified)
Input frequency: 47–440 Hz (certified 50/60 Hz)
Input current:
500 mA max @ 230 VAC
980 mA max @ 115 VAC
Inrush current:
80 A max @ 230 VAC
30 A max @ 115 VAC
No‑load power consumption: 210 mW max (ErP‑ready)
Internal fuse: T3.15A / 250 VAC (L & N)
🛡️ Safety & Isolation
Isolation: 4000 VAC, reinforced, rated for 250 VAC working voltage
Medical safety: IEC/EN/ES 60601‑1 edition 3.2, 2×MOPP
Leakage current: <100 µA, suitable for BF (Body Floating) medical applications
EMC: IEC 60601‑1‑2 (4th ed.), EN 55032 Class B
Protection class: Class I & II (per DigChip listing)
🌡️ Environmental & Reliability
Operating temperature: –40 °C to +80 °C (derating above 60 °C)
Altitude: Up to 5000 m
Construction: Fully encapsulated PCB‑mount plastic case (THD pins)
📐 Mechanical
Length: 81.3 mm
Width: 55.9 mm
Depth: 30.5 mm
Mounting: Through‑hole PCB mount
Weight: 265 g
📊 Quick Reference Table
Spec Value
Output 48 VDC, 840 mA
Power 40 W
Efficiency 93%
Isolation 4000 VAC, reinforced
Leakage <100 µA
Input 85–264 VAC / 120–370 VDC
Ripple 150–200 mVp‑p
Temp Range –40 °C to +80 °C
Mounting PCB THD
Certifications IEC/EN/ES 60601‑1 (2×MOPP), EN 62368‑1
Delivery Details:
WE DO NOT SHIP INTERNATIONALLY!UNITED STATES SHIPMENT ONLY.We try our best to ship order after payment is received.Order placed on weekends or holiday will be shipped on Monday or next business day.We will ONLY ship the item to your Confirmed Address, so pleaseconfirm thatyourdeliveryaddress is correct before youplace an order. Address cannot be changed after an order has been sent. We ship out next day if item is purchase and paid for before 1:45 pm Central. Otherwise, will be shipped out next day. We are closed on the weekends and Holidays, so no shipping nor customer service are available. For all LOCAL PICKUP, guest mustschedule an appointmentprior to pick up. Order value of $300.00 or more will require a signature to receive package to prevent loss of package. Please arrange someone to be available.

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.