B-26
New
This calculator is brand never used
I was told how to put batteries in it so I tested it and it powers on. Basically remove two screws off the back of the unit slide the metal back off put two CR 2035 in and replace the back
With that being said I have no other way of testing this unit!!
You will receive the unit actually shown I will secure for shipping
I do not warranty vintage electronics but as you can see this one powers on so you can make a decision whether or not this is for you
Free shipping
The packaging shows some wear from previous storage
I will secure for shipping
The ET Predictor II computer based on the Sharp EL-5500 III, will enable you to properly manage air/fuel ratios for the current air density, track vehicle performance or modifications, and accurately predict elapsed time and throttle stop settings according to varying weather conditions. Included are programs to calculate Air Density, Horsepower Correction, Density Altitude, Vapor Pressure, Water Grains, Engine Displacement, Compression Ratios, STP Corrected Elapsed Time, Run Completion, Corrected HP from MPH, HP Corrected Vehicle Weight, Throttle Stop Factor, and our exclusive Run Segment Analysis program. The next best thing to having an on-board computer. Comes with complete instructions and ET prediction hints and tips. Nothing is more accurate for ET Prediction! This calculator also has a square root function for calculating jet areas and sizes.
You enter the air conditions from your weather station or weather gauges into the program. We have weather instruments and weather stations available here on the website.
For Gasoline and Methanol Fuel
Drag racing programs calculate:
ET Prediction (60, 330, 660, 1000, and 1320 foot)
Throttle Stop Prediction
Air Density Index
Horsepower Correction Factor
Density Altitude
Dew Point Temperature
Vapor Pressure
Water Grains Per Pound
Corrected (STP) Elapsed Time
Run Completion
Run Segment Analysis program, the next best thing to having an on-board computer!
Predicted 60\' ET
Predicted 330\' ET
Predicted 660\' ET
Predicted 1000\' ET
Predicted 1320\' ET
Also:
Engine Displacement
Compression Ratio
Inches HG to Altitude
HP from MPH
The ET Predictor software is the most accurate ET Prediction and Weather Station software available because it uses Horsepower Correction and does not predict from an average of stored runs. The ET Predictor provides a Horsepower Correction Factor (HCF) and Air Density Index (ADI) using a standard of 0 Elevation, 29.92 In Hg Barometric Pressure, 60 degrees F Temperature, and 0 percent Relative Humidity. Under these conditions, the HCF equals 1.0000 and the ADI will equal 100.0 percent. The HCF and ADI compensate for pressure, temperature, and relative humidity. Conditions that improve the HCF and ADI are cold air, high air pressure, and low humidity.
The program uses the Elevation, Barometric Pressure, Temperature, and Humidity, to calculate the current Horsepower Correction Factor (Current HCF), Air Density Index (ADI), and Density Altitude (DA), Dew Point, and Vapor Pressure. The formulas used in this program are the same ones used in our ET Predictor II hand-held computers, ET Predictor software, and RaceLog Pro software.
Elevation - Range: -3,000 to +26,000 Feet - Elevation is only used if you are using an altimeter or a corrected barometer. If you\'re using an uncorrected barometer reading absolute pressure, always enter 0 for the elevation. If you have an altimeter, calibrate it to 29.92 In Hg and enter the reported altitude as the elevation. If you are using an analog barometer and your altitude requires that you use a corrected barometer, then you should always enter the number of feet equal to the amount of correction when you calibrated the barometer. Digital barometers and altimeters measure absolute pressure, without any need for correction, so their use is preferred.
Barometer - Range: 12 to 35 Inches Hg - If you\'re using a barometer to obtain the air pressure, enter the barometric pressure from the gauge. When using an altimeter, always enter 29.92 for the barometric pressure.
Temp F - Range: 10 to 130 degrees F - Enter the temperature from a digital thermometer or other temperature gauge. From round to round, temperature changes are apt to affect performance more than any other variable. RH% - Range: 0 to 100 Per Cent - You can use a digital hygrometer to find the relative humidity. At low temperature, relative humidity has the least effect on performance. However, at high temperatures, the effect is much greater. For example, 50% RH at 60 F will result in a .01 loss in power, while at 90 F the addition of 50% RH equals about a .03 loss in power. Changes in temperature are also more critical under high humidity
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.