SIMPLEX 2099-9754 – New, factory-sealed conventional single-action manual pull station. Ships same business day from Miami, FL on orders placed by 3 PM ET.SIMPLEX 2099-9754 Pull StationThe Simplex 2099-9754 is a conventional single-action manual pull station designed for use with conventional (non-addressable) fire alarm control panel circuits. Featuring a simple, intuitive single-pull activation mechanism, this pull station allows building occupants to manually initiate a fire alarm by pulling down on the handle — making it one of the most straightforward and reliable alarm activation devices in commercial fire protection. The red housing meets the visual identification requirements of NFPA 72 and ADA accessibility standards for manual alarm initiating devices. Single-action pull stations are among the most commonly specified manual initiating devices for conventional fire alarm systems in schools, commercial offices, retail buildings, warehouses, and industrial facilities. The 2099-9754’s conventional wiring makes it simple to install on standard two-wire initiating device circuits (IDC), and the break-rod mechanism provides clear visual confirmation that the station has been activated. After any alarm activation, the pull station is reset using a key and a replacement break-rod (2099-9804, sold separately), ensuring the device returns to its tamper-evident, ready-to-operate state. Key Features Single-action activation: simple pull-down operation — no twist or push required Conventional (non-addressable) two-wire IDC wiring — compatible with conventional FACP zones Red housing with high-visibility “FIRE — PULL DOWN” labeling per NFPA 72 Break-rod tamper evidence: broken rod provides visual confirmation of activation Key-reset mechanism — prevents unauthorized reset without authorized access Weather-resistant construction suitable for interior commercial applications ADA-compliant mounting height and activation force when properly installed UL 38 listed (Manually Actuated Signaling Boxes) Specifications Type: Single-action, conventional manual pull station Color: Red Circuit Type: Conventional two-wire IDC (initiating device circuit) Reset: Key reset with replacement break-rod (2099-9804) Standard: UL 38, NFPA 72 Mounting: Standard electrical box, surface or flush mount SIMPLEX 2099-9754 Pull Station
The Simplex 2099-9754 is a conventional single-action manual pull station designed for use with conventional (non-addressable) fire alarm control panel circuits. Featuring a simple, intuitive single-pull activation mechanism, this pull station allows building occupants to manually initiate a fire alarm by pulling down on the handle — making it one of the most straightforward and reliable alarm activation devices in commercial fire protection. The red housing meets the visual identification requirements of NFPA 72 and ADA accessibility standards for manual alarm initiating devices.
Single-action pull stations are among the most commonly specified manual initiating devices for conventional fire alarm systems in schools, commercial offices, retail buildings, warehouses, and industrial facilities. The 2099-9754’s conventional wiring makes it simple to install on standard two-wire initiating device circuits (IDC), and the break-rod mechanism provides clear visual confirmation that the station has been activated. After any alarm activation, the pull station is reset using a key and a replacement break-rod (2099-9804, sold separately), ensuring the device returns to its tamper-evident, ready-to-operate state.
Key Features
- Single-action activation: simple pull-down operation — no twist or push required
- Conventional (non-addressable) two-wire IDC wiring — compatible with conventional FACP zones
- Red housing with high-visibility “FIRE — PULL DOWN” labeling per NFPA 72
- Break-rod tamper evidence: broken rod provides visual confirmation of activation
- Key-reset mechanism — prevents unauthorized reset without authorized access
- Weather-resistant construction suitable for interior commercial applications
- ADA-compliant mounting height and activation force when properly installed
- UL 38 listed (Manually Actuated Signaling Single-action, conventional manual pull station
- Color: Red
- Circuit Type: Conventional two-wire IDC (initiating device circuit)
- Reset: Key reset with replacement break-rod (2099-9804)
- Standard: UL 38, NFPA 72
- Mounting: Standard electrical box, surface or flush mount
×
Buy now and save! Shipping info
Click the Shipping & Payments tab above the listing description for more info
Click the Shipping & Payments tab above the listing description for more info!
Additional delivery notes
PICK UP OPTION
Sorry, our items are NOT available for pick-up.
PAYMENT
Immediate payment is required upon selecting \"Buy It Now\" or upon checking out through the cart.
We accept payment via U.S. PayPal accounts and all Major Credit Cards, Debit Cards & Google Pay.
We are legally required to collect sales tax in those states and localities where we maintain a physical presence (nexus).
The applicable amount of sales tax charged to an order will be calculated based on the shipment destination\'s state and local sales tax laws.
Thank you for shopping with us on !
Additional Information
No additional information at this time
Ask seller a question
You might also like EDWARDS APS6A EDWARDS IO64R iO64 Fire Alarm Control Panel ADTRAN 1287847F1 SDX624VP 10GE 3XGE PoE Surveillance Accessory FIRE-LITE HPF-PS6 Remote Charger Power Supply 6A Contact
To contact our Customer Service Team, simply click the button here and our Customer Service team will be happy to assist.
Ask seller a question
© Plena Supply
Shipping & Payments
Click the Shipping & Payments tab above the listing description for more info
Payment
Accepted Payment Methods
Immediate payment is required upon selecting \"Buy It Now\" or upon checking out through the cart.
We accept payment via U.S. PayPal accounts and all Major Credit Cards, Debit Cards & Google Pay.
We are legally required to collect sales tax in those states and localities where we maintain a physical presence (nexus).
The applicable amount of sales tax charged to an order will be calculated based on the shipment destination\'s state and local sales tax laws.
Thank you for shopping with us on !
Returns
Returns are accepted
Items must be returned within 30 days of the sale ending
Buyer will pay for return shipping.
integration by
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.