Resideo R8182D1079 Triple Aquastat, Combinati Protector Relay & Hydronic Heating
$1,039.99

Resideo R8182D1079 Triple Aquastat, Combinati Protector Relay & Hydronic Heating100% New Resideo/Honeywell Replacement Part IMPORTANT, Please Read Before Buying.- Study The Pictures Carefully & Read The SPECS Bellow- Make Sure This Aquastat Will Fit Your System.- Professional Installation is Very required. Fast & Free Shipping, Only $1039.99Loc.Hnn SPECS / DESCRIPTIONS 120v110°F to 220°F, 130°F to 240°FVerticalSPSTBurner: 4.4 A @ 120 Vac7-1/8\"Description–Immersion type Aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems. Specifications - Use in intermittent ignition applications.
- Capable of zone control with zone valves.
- Circulator zone control with ZC and ZR terminals on R8182D,E,H,J. 8 Flame failure during the running cycle results in a 45 second attempt to restart.
- If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted.
- R8182D,E,F mount directly on burner; R8182H,J mount on 4 x 4 in. junction box and include 5 ft (1.5 m) armored capillary with remote sensor.
- C554A Cadmium Sulfide Flame Detector and a 24 Vac thermostat required.
Features - Description: Combination Protectorelay and Hydronic Heating Control with High limit: 10 F fixed; low limit/circulator: 10 F to 25 F adj. Differential
- Switching Action: SPST
- Operating Range, Low Limit (F): 110 to 220 F
- Operating Range, High Limit (F): 130 to 240 F
- Differential Temperature: High limit: 10 F fixed; Low limit/circulator: 10 F to 25 F adj.
- Anticipator Setting: .2A
- Maximum Safe Operating Pressure (psi): 200 psi on immersion well; 100 psi direct immersion.
- Electrical Rating (ignition): 360 VA
- Electrical Ratings (burner AFL): 4.4 A @ 120 Vac
- Voltage: 120 Vac
- Frequency: 60 Hz
- Timing Safety Switch: 45 sec
- Maximum Power Consumption: 9W
- Dimensions: 7 1/8 in. high x 5 1/4 in. wide x 3 7/16 in. deep.
- Insulation Depth (in.): 1-1/2 inch
- Mounting: Vertical Mount
- Operating Humidity Range: 0 to 95% RH, non-condensing
- Max Ambient Temp: 250 F at element
- Includes: Auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A Switching Relay. Heat-conductive compound and vertical case
Application: Low Limit High Limit Switch Action: SPST Electric Ratings (Ignition): 360 VA Electrical Ratings (ALR): Burner: 26.4 A @ 120 Vac Electrical Rating: Burner: 4.4 A @ 120 Vac Temperature Range (F): 110°F to 220°F 130°F to 240°F Height: 7-1/8\" Differential: Adjustable Fixed 10° to 25°F (Low Limit) Width: 5-1/4\" Max Temp Differential: 10°F Depth (Inches): 3-7/16\" Operating Humidity: 0% to 95% (non-condensing) Mount: Vertical Max Ambient Temp (°F): 250 F at Element Anticipator Rating: 0.2 A Voltage: 120v Frequency: 60 Hz Max Pressure (PSI): 100 (Direct Immersion) 200 (Immersion Well) Timing Safety Switch: 45 sec Max Power Consumption: 9 W Min Temp (F): 110°F Max Temp (F): 240°F