Free Userbar - Userbars - User Bar - User Bars
 
Advanced search
Registered users

Username:

Password:

Log me on automatically next visit?

¬ Forgot password
¬ Registration

» Upload Userbar
» Animate Userbar
» Userbars Tutorial
» Userbar Tournaments
» Forum
» Chat Room
» FAQ
» Links

• PC Cheat Codes

>> If you dont know how to design a userbar, then write here a Userbar that you want. >> If you know how to design them help these people and design what they request.




USERBARS.org | Free Forum Userbars

On eBay now
eBay

Programma TORKEL 840 Utility Battery Load Unit

Programma TORKEL 840 Utility Battery Load Unit
$8,999.99

Buy Now

Click on the image below to get zoomed view of the Item ⚡ IN STOCK Programma TORKEL 840 Utility Battery Load Unit SPECIAL OFFER: $8,999.95 Certified Pre-Owned | The Programma TORKEL 840 Battery Load Unit is built for serious utility battery discharge testing, covering 12–250 V systems with up to 110 A load current and constant current, power, resistance, current profile, or power profile test modes. Detailed Overview Programma TORKEL 840 Battery Load Unit for Utility Battery Capacity Testing

Utility and industrial standby batteries need controlled discharge testing to verify capacity before loss of reserve power becomes a service risk. The Programma TORKEL 840 Battery Load Unit supports 12–250 V battery systems with controlled load methods for capacity testing in substations, power plants, switchgear, and industrial environments. The included load cable set, power cord, and hard carrying case support transport, setup, and storage for field battery maintenance workflows.

Controlled Discharge Testing for Utility Battery Systems

The Programma TORKEL 840 applies regulated battery loading so discharge tests can be run at defined electrical conditions instead of relying on uncontrolled resistive loading. Constant current, constant power, constant resistance, current profile, and power profile modes support documented test procedures across different standby battery systems.

  • Tests 12–250 V utility battery systems commonly found in switchgear and similar equipment
  • Delivers up to 110 A load current with up to 15 kW maximum power
  • Supports in-service battery testing when external current measurement is used
Stored Test Results and PC-Based Reporting Support

The Programma TORKEL 840 stores the total voltage curve and final test readings for later transfer through TORKEL Win when supported. During connected operation, TORKEL Win can display current, voltage, capacity, and the voltage curve in real time while also supporting report generation and PC-based storage.

  • Stores total voltage curve and end-of-test readings for later review
  • Supports real-time voltage curve viewing with TORKEL Win
  • Provides selectable warning and shutdown limits for voltage, discharged capacity, and time
Field-Ready Controls, Protection, and Transport

Programma TORKEL 840 is built for high-voltage substations and industrial environments, with a front-panel LCD, operating keys, connection terminals, external control ports, and automatic protection functions. Thermal cut-outs and automatic overload protection support controlled operation during demanding battery discharge tests.

  • Hard carrying case supports transport and protected storage between jobs
  • LCD, keypad, status lamps, and front-panel terminals support direct test setup and operation
  • Thermal cut-outs, automatic overload protection, alarm output, and stop limits support safer discharge testing
Key Benefits
  • ✓ Fully Tested & Certified
  • ✓ 30-Day Risk-Free Returns
  • ✓ 1-Year Full Warranty
  • ✓ Professional Calibration Services
  • ✓ Trade-In Program Available
  • ✓ Fast & Reliable Delivery
What\'s in the Box
  • 1 x Programma TORKEL 840 Utility Battery Load Unit
  • 1 x Battery Load Cable Set
    • 1 x Red 25 mm² EUPEN FLEX H07RN-F 1x25 Cable
    • 1 x Black 25 mm² EUPEN FLEX H07RN-F 1x25 Cable
  • 1 x Power Cord
  • 1 x Hard Carrying Case
Technical Specifications Specifications TORKEL 840/860 Environment Application fieldThe instrument is intended for use in high-voltage substations and industrial environments. Operating temperature0°C to +40°C (32°F to +104°F) Storage & transport temperature-40°C to +70°C (-40°F to +158°F) Humidity5% – 95% RH, non-condensing EMC2004/108/EC LVD2006/95/EC General Mains voltage100 – 240 V AC, 50/60 Hz Power consumption (max)150 W ProtectionThermal cut-outs, automatic overload protection Dimensions, instrument210 x 353 x 700 mm (8.3” x 13.9” x 27.6”) Dimensions, transport case265 x 460 x 750 mm (10.4” x 18.1” x 29.5”) Weight21.5 kg (47.4 lbs); 38 kg (83.8 lbs) with accessories and transport case DisplayLCD Available languagesEnglish, French, German, Spanish, Swedish Measurement section Current measurement display range0.0 – 2999 A Current measurement basic inaccuracy±(0.5% of reading +0.2 A) Current measurement resolution0.1 A Internal current measurement range0 – 300 A Input for clamp-on ammeter range0 – 1 V mV/A-ratioSoftware settable, 0.3 to 19.9 mV/A Input impedance>1 MΩ Voltage measurement display range0.0 – 60 V Voltage measurement basic inaccuracy±(0.5% of reading +0.1 V) Voltage measurement resolution0.1 V Voltage measurement display range0.0 – 500 V Voltage measurement basic inaccuracy±(0.5% of reading +1 V) Voltage measurement resolution0.1 V Time measurement basic inaccuracy±0.1% of reading ±1 digit Load section Max. battery voltage288 V DC (TORKEL 840) Max. current110 A Max. power15 kW Load patternsConstant current, constant power, constant resistance, current or power profile Current setting0-110.0 A (2999.9 A)1 Power setting0-15.00 kW (299.99 kW)1 Resistance setting0.1-2999.8 Ω Battery voltage range, TORKEL 8404 ranges, selected automatically at start of test Stabilization (for internal current measurement)±(0.5% of reading +0.5 A) Range 110 – 27.6 V; 110 A highest permissible current; 0.165 Ω resistor element, nominal value Range 210 – 55.2 V; 110 A highest permissible current; 0.275 Ω resistor element, nominal value Range 310 – 144 V; 110 A highest permissible current; 0.55 Ω resistor element, nominal value Range 410 – 288 V; 55 A highest permissible current; 3.3 Ω resistor element, nominal value Inputs, maximal values External current measurement1 V DC, 300 V DC to ground. Current shunt should be connected to the negative side of the battery. Start / StopClosing/opening contact. Closing and then opening the contact will start/stop Torkel. It is not possible to keep the contacts in closed position. Delay until start200 – 300 ms Stop delay100 – 200 ms Battery480 V DC, 500 V DC to ground Voltage sense480 V DC, 500 V DC to ground Serial< 15 V Alarm250 V DC 0.28 A; 28 V DC 8 A; 250 V AC 8 A Outputs, maximal values Start / Stop5 V, 6 mA TXLRelay contact Serial< 15 V AlarmRelay contact Note 1Maximum value for a system with more than one load unit. Full Warranty Protection 1 Year Comprehensive Coverage
(Including Calibration Support & Trade-In Options) 24/7 Customer Support Contact Us Toll Free: (833) 322-7865 Local: (469) 470-9378 Email: [email protected]

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design