INTBUYING®Portable Leeb Hardness TesterProduct Overview
The Leeb hardness tester is a portable measuring instrument, and can achieve quick, lossless and high-accuracy measurement of the hardness of common metal materials. It can be used in both laboratories and engineering sites. Through the instrument measurement condition setting, it can meet a variety of measurement demands. The Leeb hardness tester can be widely used in the manufacturing industry, metal processing industry, chemical industry, commercial inspection and other detection fields, and is a professional and necessary instrument for non-destructive hardness measurement of materials.
The instrument meets the following standards:
---- <<JJG 747-1999 Leeb Hardness Tester>>
---- <<ASTM A956-06 Standard Test Method for Leeb Hardness Testing of Steel Products>>
Product ParametersMeasurement directionSupporting 360˚ measurement (vertical down, oblique down, horizontal, oblique up, vertical up)Detection range(170-960) HLD, (17.9-69.5) HRC, (19-683) HB, (80-1042) HV, (30.6-102.6) HS, (59.1-88) HRA, (13.5-101.7) HRBHardness standardHL, HB, HRB, HRC, HRA, HV, HSIndication Error±6% (HLD=800)Indication Repeatability0.8% (HLD=800)DisplayIndustrial grade 128x64 graphic lattice LCDBox size19*12*6cm (7.5*4.7*2.4 inches)Continuous working timeAbout 20 hoursOperating conditionsOperating temperature: -10˚C~50˚C
Storage temperature: -30˚C~60˚C
Relative humidity: ≤90%Applicable materialsSteel and cast steel, alloy tool steel, stainless steel, gray cast iron, nodular cast iron, cast aluminum alloy, copper zinc alloy (brass), copper tin alloy (bronze), pure copper, forged steelMain application fieldsBearings and other components;
Failure analysis of pressure vessels, turbine generator sets and equipment;
Heavy duty workpieces;
Installed mechanical or permanently assembled components;
Workpieces with limited experimental space;
Require formal original records of test results;
Material differentiation in metal material warehouses;
Rapid inspection of multiple measurement points on large workpieces.Precaution
- Sample preparation:
- During preparation of the sample surface, avoid the influence of heat, cold processing and other factors on the surface hardness of the sample as much as possible.
- If the surface to be tested is too rough, it can cause measurement errors. Therefore, the tested surface of the sample must have metallic luster exposed, and is flat, smooth and free of oil stains.
- Curved surface: The tested surface of the sample is preferably flat. Samples with the tested surface curvature radius R of less than 30mm should be supported with small or irregular support rings during testing.
- Sample support:
- For heavy-duty samples, no support is required.
- For medium-sized samples, they must be placed on a flat and sturdy surface and be placed absolutely stably without any shaking.
- The sample should have sufficient thickness, and the minimum thickness of the sample should comply with the impact device parameter list.
- For samples with surface hardening layers, the depth of the hardening layer should comply with the impact device parameter list.
- Coupling:
- For the light-duty sample, it must be tightly coupled with a sturdy support, and the two coupling surfaces must be flat and smooth, with an appropriate quantity of coupling agent. The testing direction must be perpendicular to the coupling plane.
- When the sample is a large-area plate, long rod or bent part, even if the weight and thickness are large, it may still cause deformation and instability of the sample, resulting in inaccurate test values. Therefore, reinforcement or support should be provided on the back of the test point.
- The magnetic properties of the sample itself should be less than 30 Gauss.
Product Features & Advantages
Refined & Portable
1. Delicate appearance, easy to use and convenient to carry.
2. High-brightness LCD, clear under direct sunlight, backlight function.
3. High-precision circuit: indication error ±6% (HLD=800), repeatability 0.8%.
Multi‑Standard & Smart
4. Supports multiple hardness standards: HLD, HRC, HRB, HRA, HB1, HB2, HV, HSD.
5. Automatic calculation & average hardness value.
6. ‘Forged steel’ material support — direct HB readout for D-type impact device.
Modern Utility & Durability
7. Type-C charging port, compatible with mobile devices.
8. Data saving function for recording and checking.
9. Auto shutdown in 10 minutes.
10. Protective toolbox stores tester and parts, prevents damage.Advantage Comparison
The Leeb principle offers superior portability vs benchtop testers; real-time data logging; wide material coverage including steel, cast iron, aluminum alloys; compliance with ASTM A956 and JJG 747 standards ensures reliable industrial acceptance.Operation Method
1. Power on:
Press the ‘OFF/ON’ button to turn on or off the instrument. After turning on the tester, the instrument will automatically enter the measurement state after self-inspection.
2. Loading:
Push the loading sleeve downwards to lock the impact body, and now the loading is completed. Press the support ring of the impact device tightly onto the surface of the sample, and the impact direction should be perpendicular to the test surface.
3. Measurement:
The distance between any two indentations or the distance between the center of any indentation and the edge of the sample shall comply with the following provisions:
Distance between the centers of two indentations: ≥3mm
Distance between the indentation center and the edge of the sample: ≥5mm
Press the release button on the upper part of the impact device to perform the test. At this point, it is required that the sample, impact device and operator are all stable, and the direction of the applied force should pass through the axis of the impact device. Each measuring part of the sample is generally subjected to three or more tests, and the average value is read as a piece of Leeb hardness test data. At this point, press the up or down arrow keys to view the previous or next test value.
4. Press and hold the ‘SET/SAVE’ button to save the current test data.
5. Press and hold the ‘UNIT’ button on the measurement interface to enter and view the saved data group. Press the up or down arrow key to view the saved data. Long press the up arrow key to delete all saved data. Press the ‘SET/SAVE’ button to view detailed records.
Item Included (056107)
1 x Portable Leeb Hardness Tester (with standard accessories, impact device D, calibration test block, carrying case, etc.)
You can make order with no worry.
Any concern just feel free to let us know, we\'ll reply in 24 hours in normal condition.
Handling Time: Shipping is usually made in 1-3 business days after payments cleared. Orders are processed from Monday-Friday; Not on the weekends & public holidays.
Warranty: 6 months\' warranty for the machines, not for the consumables.
We stand behind our products all the item, so even if your warranty period has expired, you can still seek for service or technical support from us with low cost.
On Mar 27, 2026 at 02:29:17 PDT, seller added the following information:
On Mar 27, 2026 at 18:50:59 PDT, seller added the following information:
On Mar 27, 2026 at 18:59:09 PDT, seller added the following information:
On Mar 27, 2026 at 19:16:05 PDT, seller added the following information:
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.