|
>> If you dont know how to design a userbar, then write here a Userbar that you want.
>> If you know how to design them help these people and design what they request.
|
 |
 |
USERBARS.org | Free Forum Userbars
| On eBay now |
Portable 4/8'' Patient Monitor Vital Signs for Hospital NIBP, SPO2, PR, TEMP
$198.08

ETERFANT 8\" Patient Monitor ICU CCU Vital Sign For Hospital NIBP, SPO2, PR,TEMP (PM80B) Standard Parameters: NIBP, SPO2, PR,TEMPFeatures: 1.Compact and flexible appearance. 2.Simple and convenient operation, which is applicable for community medical treatment and family ect. 3.8 inch high resolution color TFT display. 4.Adjustable audible and visual alarms. 5.Built-in rechargeable lithium battery for uninterrupted monitoring.Technique Range: 0 ~ 100 % ②Resolution: 1% ③Accuracy: 70% ~ 100% (2 %) ④Pulse Rate: 20-250 BPM ⑤Resolution: 1 BPM ⑥Accuracy: 3 BPM2.NIBP 2.1.Method: Oscillometry 2.2.Measure mode: Manual, Auto, STAT 2.3.Unit: mmHg, kPa 2.4.Measure and alarm range: 2.5.Adult Mode ①SYS 40 ~ 280 mmHg ②DIA 10 ~ 225 mmHg ③MEAN 20 ~ 240 mmHg 2.6.Pediatric Mode ①SYS 40 ~ 220 mmHg ②DIA 10 ~ 160 mmHg ③MEAN 20 ~ 170 mmHg 2.7.Neonatal Mode ①SYS 40 ~ 135 mmHg ②DIA 10 ~ 100 mmHg ③MEAN 20 ~ 110 mmHg 2.8.Resolution: 1mmHg 2.9.Accuracy: 5mmHg3.TEMP ①Measure and Alarm Range: 0 ~ 50 C ②Resolution: 0.1C ③Accuracy: 0.1CStandard Configuration: 1.Main Unit *1 2.Adult Spo2 probe *1 3.Adult NIBP cuff *1 4.NIBP extension tube *1 5.Power Cable *1 6.Power adapter *1 7.User Manual *1 8.Temperature probe Patient Monitor ICU CCU Vital Sign For Hospital NIBP, SPO2, PR,TEMP(L4A)Standard Parameters: NIBP, SPO2, PR,TEMPApplication Range: Operation, operative/anesthetic recovery, emergency room for adult, children and neonatal babyFeatures: • 4inch high-resolution color TET LCD display. • Optional NIBP, EtCo2 function. • Compact and portable in design, allowing for uninterrupted monitoring. • AC power supply, together with built-in lithium battery. • Auto double alarm with audible and visible signals. • Up to 36-hour patients’ trend date in storage, easy to recall. • Optional printing output function, alarm triggers printing.NIBP •Static pressure range 0~300 mmHg • Static pressure precision ±3 mmHg • Pressure precision Max. average error :±5 mmHg, Max. standard deviation : 8 mmHgSpO2 • Measurement range 0~100% • Accuracy 70~100%: ±2 DIGIT • 0~69%: no definition given • Resolution 1%Parameter: • Dimension: 244mm*186mm*82mm • Weight: 1.5kg • Power Requirements: Lithium Battery capacity: 2200mAh • Operation Temperature 0℃~40℃ • Transportation and storage Temperature -20℃~60℃ • Ambient Humidity ≤85% • Transportation and storage Humidity ≤93% • Atmosphere pressure 86kPa~106kPaFDAStatement: Thanksforyourunderstanding!

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
|
|
|
 |
 |
|