Precautions for Replacing and Installing the Compressor
Step I. Inspection
- Inspect the original compressor\'s malfunction conditions and the state of the refrigeration oil.
- Inspect the power supply, voltage, starter, and overload protector.
- Inspect the condenser, evaporator, capillary tube, and refrigerant piping.
- Confirm the compatibility of the new compressor model, refrigerant, voltage, and frequency.
Step II. Construction
- Disconnect the power supply and recover the refrigerant in the system.
- Remove the original compressor, inspect, and clean the refrigeration piping.
- Replace the desiccant filter, install the new compressor, and weld the pipelines.
- Conduct leak testing using dry nitrogen.
- Proceed with vacuuming after confirming no leaks.
- Charge the refrigerant according to the model and filling quantity specified on the refrigerator nameplate.
- Power on and test the machine, checking the compressor\'s operating current, voltage, and cooling effect.
- Complete the maintenance after confirming normal operation.
※Please seek professionals to install the product.
※If the above steps are completed before construction, it will ensure the extended lifespan of the compressor while maximizing cooling capacity and saving electricity.
- Shipping Policy
- Payment Method
- Returns Policy
Shipping Policy
We only ship the item to PayPal verified shipping address. Please make sure your shipping address is the same as PayPal, no changes are allowed once the order is shipped.
All USA location orders will be shipped out viaUSPSorUPSorFedexwith a tracking number.We do not ship toP.O. Boxes, APO/FPO orMilitary Mail Box.
We do not cover any import Duty and Tax. Customer should be responsible for the Import tax. Contact us , we will try our best to help minimize it.
HK/TW buyer please notice us your government ID #.
BRA,AR,PER buyer leave us your CPF#,CUIT#,RUC# correspondingly.
Payment Method
We acceptPaypalonly for the payment thru , please do not pay directly to our Paypal account.
Paypal allows to pay by Credit Card, Direct Debit, VISA, eCheck, or other methods, please kindly check Paypal for more please add items to your shopping cart and pay once for entire order.
Returns Policy
Please kindly contact us before return, ourrepresentatives will send you detail return instruction.
The guarantee will be only for the cost of the item, we will not responsible for installation or other fees likelabor expenses, towing expenses, additional repair expenses or other related expenses.
Product ViewDetails
Specifications:
990 BTU
R134a
110/120 Volts
LBP
Electricals: Relay, Start and Run Capacitor (PTC)
4\"X6\" Footprint
Grommets and Sleeves
OEM Part Number:
NF9FX, PC990L
Precautions for Replacing and Installing the Compressor
Step I. Inspection
- Inspect the original compressor\'s malfunction conditions and the state of the refrigeration oil.
- Inspect the power supply, voltage, starter, and overload protector.
- Inspect the condenser, evaporator, capillary tube, and refrigerant piping.
- Confirm the compatibility of the new compressor model, refrigerant, voltage, and frequency.
Step II. Construction
- Disconnect the power supply and recover the refrigerant in the system.
- Remove the original compressor, inspect, and clean the refrigeration piping.
- Replace the desiccant filter, install the new compressor, and weld the pipelines.
- Conduct leak testing using dry nitrogen.
- Proceed with vacuuming after confirming no leaks.
- Charge the refrigerant according to the model and filling quantity specified on the refrigerator nameplate.
- Power on and test the machine, checking the compressor\'s operating current, voltage, and cooling effect.
- Complete the maintenance after confirming normal operation.
※Please seek professionals to install the product.
※If the above steps are completed before construction, it will ensure the extended lifespan of the compressor while maximizing cooling capacity and saving electricity.
- Shipping Policy
- Payment Method
- Returns Policy
Shipping Policy
We only ship the item to PayPal verified shipping address. Please make sure your shipping address is the same as PayPal, no changes are allowed once the order is shipped.
All USA orders will be shipped out viaUSPS, UPSorFedexwith a valid tracking number.We do not ship toP.O. Boxes, APO/FPO orMilitary Mail Boxes.
We do not cover any import Duty and Tax. Customer should be responsible for the Import tax. Contact us , we will try our best to help on minimizing it.
For HK/TW buyers, please notify us your government ID #.
For BRA,AR,PER buyers, please leave us your CPF#, CUIT# or RUC# correspondingly.
Payment Method
We acceptPaypalonly for the payment thru , please do not pay directly to our Paypal account.
Paypal allows to pay by Credit Card, Direct Debit, VISA, eCheck, or other methods, please kindly check with Paypal for more please add items to your shopping cart and pay once for the entire order.
Returns Policy
Please kindly contact us before returning your order(s), ourrepresentatives will send you the detailed instructions.
Our guarantee is only for the cost of the item, we will not be responsible for any other expenses such as installation, labor, towing, repair or any other related expenses.
On Sep 22, 2026 at 02:57:37 PDT, seller added the following information:
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.