Oxford Instruments ILM 210S Intelligent Helium Level Meter | Part No. 613 310 Item Overview
Used Oxford Instruments ILM 210S Intelligent Helium Level Meter removed from a Varian Mercury Plus 400 NMR system. The meter powers on and its display was observed sequencing through “S.06,” “HE,” and “Err” while no helium-level probe was connected. No testing with a compatible probe, cryostat, magnet, or complete NMR system was performed. Identification & Specifications ManufacturerOxford Instruments ModelILM 210S DescriptionIntelligent Helium Level Meter Part Number613 310 Serial NumberCV 210/0136 Inventory ReferenceVMP-007 / Spreadsheet Item 97 Typical ApplicationLiquid-helium level monitoring in compatible cryogenic, superconducting-magnet, and NMR systems Observed Power-On Test
- Unit powered on successfully.
- Display was observed showing “S.06,” followed by “HE,” followed by “Err.”
- No helium-level probe was connected during this test.
- No further functions, measurement accuracy, outputs, communications, alarms, calibration, or compatibility were tested.
- The cause and meaning of the displayed error were not independently diagnosed.
Included
- One Oxford Instruments ILM 210S Intelligent Helium Level Meter, Part No. 613 310, Serial No. CV 210/0136
- Only the item specifically shown in the listing photographs is included.
- No power cord, helium probe, probe cable, NMR console, magnet, manuals, calibration records, or other system components are included.
Condition
Used surplus scientific equipment with cosmetic wear consistent with prior installation, storage, and handling. Scratches, scuffs, dust, discoloration, residue, label wear, and other signs of use may be present. Please examine all photographs closely; the photographs are part of the item description and show the actual unit offered.
Compatibility
Buyer is solely responsible for confirming model, part number, connector type, probe requirements, system compatibility, configuration, calibration needs, and suitability for the intended application before purchase. This listing does not represent that the unit is compatible with every Oxford Instruments, Varian, Agilent, NMR, cryostat, or superconducting-magnet system.
Testing Disclosure
This unit received only the limited power-on observation described above. A compatible helium-level probe and operating cryogenic system were not available. The “Err” indication was observed with no probe connected, but its cause has not been verified. The meter is not represented as fully tested, calibrated, or ready for service. Shipping & Handling
The unit will be carefully packed for shipment. The original factory box, packaging, manuals, and accessories are not included unless shown. Recycled packing materials may be used when appropriate to reduce waste while protecting the item.
Important Buyer Notice
Specialized cryogenic and laboratory equipment should be inspected, tested, calibrated, serviced, and installed by qualified personnel before use. Buyer assumes responsibility for safe installation, configuration, operation, maintenance, and compliance with all applicable requirements. Disclaimer
Regardless of the equipment’s origin, documentation, markings, or prior application, this item is not certified, fully tested, warranted, or guaranteed for any particular use. All descriptions and identifiers are provided for identification purposes and must be independently verified by the buyer. No warranty is expressed or implied. The seller is not responsible for incidental or consequential damages arising from installation, testing, use, or misuse of this equipment. GALAXY INDUSTRIES LLC Colorado Springs, Colorado Surplus Industrial • Scientific • Electronic Equipment
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.