NEW NI USB-8473 for LabVIEW Net Comm USB Bench USB-CAN 1 Port CAN Bus-Powered

NEW NI USB-8473 for LabVIEW Net Comm USB Bench USB-CAN 1 Port CAN Bus-Powered
$133.99

Buy Now

USB-8473 - Single-Port High-Speed CAN Bus Interface for USB (Bus Powered, 500 V USB-8473 is a single-port, high-speed controller area network (CAN) interface that connects any PC with a USB port

to a CAN network or CAN device. It is built around a dedicated SJA1000 CAN protocol controller and a built-in TJA1041

high-speed transceiver compliant with ISO 11898, and it handles both CAN 2.0A (11-bit) and extended CAN 2.0B (29-bit)

arbitration IDs at baud rates from 40 kbit/s up to 1 Mbit/s. Because everything - controller, transceiver, termination

reference and isolation - lives inside one enclosed module fed by a captive 2 m USB cable, there is no separate dongle,

no external power supply and no extra cabling to buy.


✨ Key Features

- Single-port high-speed CAN (ISO 11898) interface with built-in transceiver - ready to connect straight to the bus

- Baud rates from 40 kbit/s to 1 Mbit/s (1000 kbit/s)

- CAN 2.0A 11-bit standard and CAN 2.0B 29-bit extended arbitration IDs, suitable for J1939 and CANopen traffic

- 500 VDC channel-to-bus isolation (withstand rating, 2 s maximum) protects your PC and bus equipment from

high-voltage spikes

- Fully USB bus powered through an internal DC/DC converter - the CAN physical layer needs no external bus supply

- Hardware timestamping with 1 us read resolution, so logged frames can be replayed in true event order

- Integrated frame buffering records full bus load at 1 Mbit/s without dropping frames

- Listen-only, self-reception (echo), sleep/wake and advanced filtering modes, plus error counter access

- 9-pin male D-Sub (DB-9) CAN connector and two front-panel LEDs (USB, CAN) for instant status

- Compact enclosed housing, 7.87 x 6.35 x 2.54 cm, with a captive 2 m USB cable; 0 C to 55 C operating range


🧪 Usage Scenarios

- Monitoring, sniffing and logging in-vehicle CAN networks during road tests or on a bench

- Automotive diagnostics work: reading engine and body network traffic, watching bus load and error frames

- Heavy-duty, agricultural and off-highway diagnostics on J1939 powertrain and drivetrain buses

- ECU and CAN node development: bringing up new nodes, exercising them, and validating message timing

- End-of-line and functional test stands for CAN-enabled subassemblies

- Industrial machine networks running CANopen or similar higher-layer protocols

- Teaching and training labs for vehicle networking and CAN protocol ................. USB-8473 (779792-01 / 779792-02; 194210C-01)

Function .............. Single-port high-speed CAN to USB interface

CAN controller ........ SJA1000

CAN transceiver ....... TJA1041 high-speed, built in

Physical layer ........ High-speed CAN, ISO 11898 compliant

Number of ports ....... 1

Baud rate ............. 40 kbit/s to 1 Mbit/s (1000 kbit/s)

Arbitration IDs ....... CAN 2.0A 11-bit and CAN 2.0B 29-bit extended

Isolation ............. 500 VDC, channel-to-bus withstand (2 s maximum)

Timestamping .......... Hardware, 1 us read resolution

Operating modes ....... Listen-only, self-reception (echo), sleep/wake, filtering

Remote frames ......... Not supported

Bus power ............. None required; powered internally from USB

Power requirement ..... 5 VDC, 250 mA from USB bus

Host interface ........ USB 2.0 Hi-Speed compatible, captive 2 m cable

CAN connector ......... 9-pin male D-Sub (DB-9)

Synchronization ....... Not available on this version (see the "s" variant)

Indicators ............ Two LEDs: USB, CAN

Dimensions ............ 7.87 x 6.35 x 2.54 cm (3.1 x 2.5 x 1.0 in.)

Operating temp ........ 0 C to 55 C

Storage temp .......... -20 C to 70 C

API ................... Frame API (limited), supplied with the driver

Operating system ...... Windows 10 / 11 (driver software & USE

1. Install the CAN driver software and any configuration utility BEFORE plugging in the device.

2. Connect the captive USB cable to a free PC port; the USB LED confirms enumeration.

3. Plug the 9-pin D-Sub into your CAN harness or device under test. Observe correct CAN_H / CAN_L polarity and

keep termination appropriate for the network.

4. Set the baud rate and frame format in the configuration utility to match the target network.

5. Start with listen-only mode to confirm traffic appears without transmitting onto the bus, then move to full

participation once you trust the setup.

6. Fit the bus with the correct two 120 ohm terminations if you are building a standalone bench