Modbus RTU 4-way relay module 12V 4-way switch input optocoupler isolation RS485
$14.59

Relay voltage: 12V relay delivered by default, 12V power supply. Relay communication: multi unit network 485 communication, based on mbdbus-rtu protocol, the default communication address is 1, the user can modify the address by command In1 - In4 is used to connect the switch, read the switch status through 485, not to control the relay output through input. Note: In1-In4 cannot be connected to 220V (some buyers will make this kind of mistake) The following is the connection mode: In1 - GND (high level by default, low level after switch on) computer sends command to read switch status. In2 - GND (high level by default, low level after switch on) computer sends command to read switch status. In3 - GND (high level by default, low level after switch on) computer sends command to read switch status. In4 - GND (high level by default, low level after switch on) computer sends command to read switch status. Size: 76mm * 67mm * 17.5mm Board resources: 1. S1 reset button 2. D5 running LED indicator Control command into the group to share and download. 1. 4 relay outputs (one normally open and one normally closed) 2. Stm8s103f3 single chip microcomputer 3. 4-channel optocoupler isolation relay output 4.4 relay closed LED indicator 5. Circular DC interface, with terminal DC interface. Convenient power wiring (Power Supply Voltage 5V or 12V depends on relay voltage) 6. 4 input interfaces (dry node input, passive input, connected with GND) 7. One RS485 communication interface. 8. One power indicator 9. One user LED 10. Reset button 11. A swim Download Interface - (stlink-v2 download program, users can secondary development program) Main circuit diagram of secondary program development: 1. LED connected to user LED 2. TX Rx is connected with 485 port and TTL port 3. Key user button (red button on the left) 4. En 485 user end 5. The In1 - In4 input port is directly connected to the terminal 6. K1 - K4 relay output control 7. SWIM burning program J13 Quantity: 1pcs

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
|
|
|
 |
 |
|