Free Userbar - Userbars - User Bar - User Bars
 
Advanced search
Registered users

Username:

Password:

Log me on automatically next visit?

¬ Forgot password
¬ Registration

» Upload Userbar
» Animate Userbar
» Userbars Tutorial
» Userbar Tournaments
» Forum
» Chat Room
» FAQ
» Links

• PC Cheat Codes

>> If you dont know how to design a userbar, then write here a Userbar that you want. >> If you know how to design them help these people and design what they request.




USERBARS.org | Free Forum Userbars

On eBay now
eBay

Megger MS-2A Circuit Breaker & Overcurrent Relay Test Set

Megger MS-2A Circuit Breaker & Overcurrent Relay Test Set
$7,776.99

Buy Now

Click on the image below to get zoomed view of the Item ⚡ IN STOCK Megger MS-2A Circuit Breaker & Overcurrent Relay Test Set SPECIAL OFFER: $7,777.00
  • Megger MS-2A circuit breaker and relay test set delivers portable primary-injection testing for breakers, overload relays, overcurrent relays, and ground-fault trip devices with adjustable high-current output up to 750 A and integrated timing.
Detailed Overview Circuit Breaker and Overcurrent Relay Testing with Megger MS-2A

The Megger MS-2A circuit breaker and overcurrent relay test set solves the field challenge of applying controlled high current while measuring protective-device trip behavior. Its integrated configuration combines variable AC output, ammeter measurement, timer control, and a portable enclosure for breaker, relay, overload, ground-fault, CT ratio, and panelboard meter test workflows.

High-Current Primary Injection for Protective Device Testing

The MS-2A supports primary-injection testing by delivering adjustable AC current through selectable output ranges. Momentary and maintained output modes help match the test method to instantaneous trip checks, time-delay verification, and device operation timing.

  • Adjustable AC output ranges from 0 to 5 A, 0 to 25 A, 0 to 120 A, and 0 to 240 A
  • Short-duration output up to 750 A through a typical 125 A molded-case circuit breaker
  • Momentary and maintained output modes for trip-current and time-delay testing
Integrated Current Measurement and Trip Timing

The Megger MS-2A combines current readout and timing functions to reduce the need for separate measurement setup during protection testing. Ammeter memory mode, multiple current ranges, and timer control conditions support repeatable capture of trip current and operating time across common protective-device configurations.

  • Ammeter ranges of 0 to 1.999 A, 19.99 A, 199.9 A, and 750 A
  • Timer ranges of 0 to 99.999 seconds, 0 to 999.99 seconds, and 0 to 99999 cycles
  • Timer control for current-actuated, normally closed, and normally open test circuits
Protection Testing Use Across Breakers, Relays, and Metering Workflows

The Megger MS-2A supports electrical protection maintenance where technicians need to confirm that protective devices operate at the intended current and within the expected trip time. Its test scope extends from molded-case circuit breakers and overcurrent relays to motor overload relays, ground-fault trip devices using window CTs, current transformer ratio checks, and panelboard ammeter or voltmeter testing.

  • Molded-case circuit breaker testing for time-delay and instantaneous trip operation
  • Overcurrent relay and motor overload relay testing for protective-device response checks
  • Ground-fault trip device, CT ratio, panelboard ammeter, and panelboard voltmeter testing
Key Benefits
  • ✓ Fully Tested & Certified
  • ✓ 30-Day Risk-Free Returns
  • ✓ 1-Year Full Warranty
  • ✓ Professional Calibration Services
  • ✓ Trade-In Program Available
  • ✓ Fast & Reliable Delivery
What\'s in the Box
  • 1 x Megger MS-2A-230 Circuit Breaker & Overcurrent Relay Test Set
  • 2 x Red test leads, 200 cm
  • 2 x Black test leads, 200 cm
  • 2 x Red alligator clips
  • 2 x Black alligator clips
  • 2 x No. 2 high-current leads, 2 ft
  • 5 x 0.125 A, 250 V MDL fuses
  • 1 x Instruction manual
  • 50 x Green test/maintenance record cards
  • 50 x Buff test/maintenance record cards
  • 1 x Universal travel power adapter 
Technical Specifications InputInput Voltage230 V input versionFrequency50/60 HzPhase1φOutputOutput RangesContinuously adjustable in four ranges: 0 to 5 A at 120 V max; 0 to 25 A at 24 V max; 0 to 120 A at 6 V max; 0 to 240 A at 3 V maxOutput CapacityDesigned to permit short-duration overloads; output ranges provide several times their current rating when output voltage is sufficient for the test-circuit impedanceTime-Delay Test CapabilityDevices rated up to 125 A using a test current of three times rating, 375 AInstantaneous Trip Test Capability750 A through a typical 125 A molded-case circuit breaker connected with the supplied test leadsOverload Capability100% rated current: 30 min on / 30 min off; 200% rated current: 3 min on / 8 min off; 300% rated current: 30 s on / 4 min offOutput Initiate CircuitSolid-state output initiating circuit using a triac instead of a contactorOutput Duration ModesMomentary and maintainedInstrumentation — AmmeterOperating ModesMemory; NormalDisplay3-1/2 digit, extra-bright LED display with 0.3 in. numeralsRanges0 to 1.999 A; 19.99 A; 199.9 A; 750 AContinuous Accuracy±1% of reading, ±1 digit on three high ranges; ±1% of range, ±1 digit on low rangeInstrumentation — TimerDisplay5-digit, extra-bright LED display with 0.3 in. numeralsRanges0 to 99.999 s; 0 to 999.99 s; 0 to 99999 cyclesAccuracy±0.005% of reading, ±1 digitTimer Control CircuitTimer Start / StopAutomatically starts when output is energized; automatically stops timer and de-energizes output when the device under test operatesCurrent Actuated ModeFor devices with no auxiliary contacts to monitor; timer stops when output current is interruptedNormally Closed ModeFor devices with normally closed contacts; timer stops and output is de-energized when contacts openNormally Open ModeFor devices with normally open contacts; timer stops and output is de-energized when contacts closePhysicalEnclosureHigh-strength molded suitcase-type enclosure with carrying handle, removable cover, and storage space for test leadsStandardsCE; EN 61326-2-1; EN 61010-1; EN 61010-031Dimensions18 W × 9.5 H × 13.5 D in.Weight33 lbOrdering InformationModelMS-2ACatalog NumberMS-2A-230 Full Warranty Protection 1 Year Comprehensive Coverage
(Including Calibration Support & Trade-In Options) 24/7 Customer Support Contact Us Toll Free: (833) 322-7865 Local: (469) 470-9378 Email: [email protected]

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design