Came from a University, was told it worked. Only can test power and that works. Comes with power cord
Multi-Operational Apparatus for Reaction Time (MOART)
Model 35601
Employ simple reaction time tasks such as Go / No Go tasks for the study of higher centers of the brain, and more complex discriminate reaction time tasks to study cognitive processing. Includes MOART Panel Only. Panel requires either the PsymLab Software, Model 35800A or the PsymCon Control, Model 35500 for administration.
Tests
Simple Reaction Time: Choose either simple stimulus with response or Go / No Go reaction paradigm.
Choice Reaction Time: Choose from multiple stimuli and multiple responses.
Simple Reaction / Movement: Choose either simple stimulus with response or Go / No Go reaction paradigm with an added movement response.
Choice Reaction / Movement: Subject starts from a single key and responds to one of multiple response keys based on stimulus presented.
Simple Tap Test: The subject taps one key as quickly as possible during a timed test period.
Complex Tap Test: The subject alternately taps two separate keys as quickly as possible for a predetermined test time.
Additional test features available with PsymLab
Reaction Time + Tapping Test: The subject is instructed to perform a reaction time test while simultaneously performing a tapping task.
Within each of these test types, the user can set several variable parameters to meet their needs. These parameters include: Choice of Stimulus, Reaction Method, Cue Type, Length of Cue, Error Types, Response Time Out, and Random Presentation
Specifications
Cue Time: Variable from 0 - 25.5 seconds, 0.1 second resolution
Cue Time Range: Variable from 0 - 25.5 seconds, 0.1 second resolution
Error Type: Early response, no response, incorrect response or inaccurate response
Response Time Out: Variable from 0 - 25.5 seconds, 0.1 second resolution
Tapping Duration: Variable from 0 - 25.5 seconds, 0.1 second resolution
Power Requirements: 12VDC, 1.0 Amp supplied with AC adapter
Computer Connection: USB
Timing Resolution / Accuracy: 1.0 millisecond +/- .001%
Dimensions: 21.0\" x 11.2\" x 2.5\"
Control Interface: PsymCon Model 35500 or PsymSoft Model 35800
Stimulus
Tri-color lights (9)
High tone or low tone
Random or fixed presentation
Touch sensitive keys (10) with inner and outer target hotspots for accuracy measurement
Reaction/Movement Keys
Tri-color light
High tone
Low tone
Cue
Fixed
Random
None