Kimray 230 SGT BPNV DI
This is a pilot-operated, non-venting back-pressure regulator used primarily in oil-and-gas service. The current Kimray equivalent is:
- Kimray item code: ALED
- Configuration code: RBN2SADF1S
- Current description: 230 SGT BP‑NV‑D REG
Model-code interpretation
- 230: 2-inch connection, 300-psig maximum working pressure
- S: Female NPT “screwed” connections
- G: Gas-operated regulator
- T: Through-body flow pattern
- BP/BPNV: Back-pressure, non-venting
- DI/D: Ductile-iron body
Technical description
The regulator maintains a selected upstream pressure. When upstream pressure rises above the set point, its pilot modulates the main valve open, allowing more flow downstream. When upstream pressure falls, the valve closes to conserve pressure.
A spring-loaded pilot senses upstream pressure through a diaphragm and controls the pressure acting on the main-valve diaphragm. The non-venting configuration does not intentionally discharge process gas to atmosphere, making it useful for emissions reduction and enclosed installations. Kimray specifies clean, dry gas at the pilot for reliable female NPTBody configurationThrough bodyBody materialCast ductile ironServiceGasOperationPneumatic, pilot operatedPressure set-point range10–300 psigMaximum working pressure300 psigMinimum differential pressure10 psiTrim2-inch, full-port, equal-percentageMaximum flow coefficientCv 47Shutoff ratingANSI/FCI Class VIFace-to-face length8.5 inchesApproximate weight39 lbNACE MR0175Available as an option—not necessarily includedRecommended repair kitRDGNV
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.