Keithley 6512 Programmable Electrometer Meter
Comes with a manual and what you see in the pictures. If you don\'t see it, you probably wont get it.
Specifications are from Keithley and may vary slightly due to upgrades, options, or revisions this unit may or may not have.
The unit has been tested and is guaranteed to work for 30-days, parts and labor, excluding freight. We can have the unit calibrated if needed (at an additional cost). There is some discoloration on the case of this unit. The serial number tag is also a printed version that I think the previous user did. Not sure if they lost the original serial number tag or what.
The Unit\'s Serial Number Tag Reads:
Model Number: 6512
Serial Number: 0621678
Key Features:
< 2fA to 20 mA measurement range
Resistance measurements from 100 mΩ to 200GΩ
10 µV to 200 V voltage measurement range (with > 200 TΩ input impedance)
Charge measurements from 10 fC to 20 nC
5 fA of input bias current
<1 mV of burden voltage
Built-in V-Ω guard
Built-in IEEE-488 interface Description:
The five-function Model 6512 Programmable Electrometer combines exceptional performance specifications with a low cost. It has just 5 fA of input bias current and <1 mV of burden voltage, ensuring accurate low-level current and charge measurements. With >200 TΩ input impedance, it\'s well suited for high accuracy voltage and resistance measurements. The 6512\'s exceptional input impedance and input offset current specifications also help ensure high measurement integrity in applications where other instruments would have detrimental effects on the circuit being measured.
The 6512 offers full autoranging over the full span of measurement ranges: current from < 2 fA to 20 mA, resistance from 100 mΩ to 200 GΩ, voltage from 10 µV to 200 V and charge from 10 fC to 20 nC.
Volts Specifications:
Range:Resolution:Accuracy (1 Yr.)*
18° - 28°C
±(%rdg + counts):Temperature Coefficient
0° - 18°C & 28°C - 50°C
±(%rdg + counts)/°C:200 mV10 µV0.05 + 50.004 + 32 V100 µV0.05 + 10.004 + 0.320 V1 mV0.05 + 10.005 + 0.1200 V10 mV0.07 + 10.007 + 0.1 NMRR: > 80 dB on 200 mV, 60 dB on 2 V and 20 V, 55 dB on 200 V range, at 50 Hz or 60 Hz ±0.1%
CMRR: > 120 dB at DC, 50 Hz or 60 Hz.
Input Impedance: > 200 T Ω in parallel with 20 pF (< 2 pF guarded).
Notes:
*: When properly zeroed.
Amps Specifications:
Range:Resolution:Accuracy (1 Yr.)*
18° - 28°C
±(%rdg + counts):Temperature Coefficient
0° - 18°C & 28°C - 50°C
±(%rdg + counts)/°C:2 pA100 aA1.6 + 660.15 + 820 pA1 fA1.6 + 70.15 + 1200 pA10 fA1.6 + 10.15 + 0.12 nA100 fA0.25 + 50.015 + 320 nA1 pA0.25 + 10.015 + 0.3200 nA10 pA0.25 + 10.015 + 0.12 µa100 pA0.15 + 40.005 + 320 µA1 nA0.15 + 10.005 + 0.3200 µA10 nA0.15 + 10.006 + 0.12 mA100 nA0.15 + 40.005 + 3200 V1 µA0.15 + 10.005 + 0.3 Input Bias Current: < 5 fA (5 x 10-15 A) at 23°C
Input Voltage Burden: < 1 mV except 3 mV on 20 mA range.
Preamp Settling Time (to 10% of final value): 2.5 s on pA ranges, 15 ms on nA ranges, 5 ms on µA and mA ranges.
NMRR: > 95 dB on pA, 60 dB on nA, µA, and mA ranges at 50 Hz or 60 Hz ±0.1%.
Notes:
*: When properly zeroed.
Coloumbs Specifications:
Range:Resolution:Accuracy (1 Yr.)*
18° - 28°C
±(%rdg + counts):Temperature Coefficient
0° - 18°C & 28°C - 50°C
±(%rdg + counts)/°C:200 pC10 fC0.4 + 40.02 + 32 nC100 fC0.4 + 10.02 + 0.320 nC1 pC0.4 + 10.02 + 0.1 Input Bias Current: < 5 fA (5 x 10-15 A) at 23°C.
Notes:
*: When properly zeroed.
Ohms Specifications:
Range:Resolution:Accuracy (1 Yr.)*
18° - 28°C
±(%rdg + counts):(Temperature Coefficient
0° - 18°C & 28° - 50°C
±(%rdg + counts)/°C:Test Current ±1.5%:
2 kΩ
100 mΩ
0.20 + 4
0.01 + 3
100 µA
20 kΩ
1 Ω
0.15 + 1
0.01 + 0.3
100 µA
200 kΩ
10 Ω
0.25 + 1
0.01 + 0.3
10 µA
2 MΩ
100 Ω
0.25 + 1
0.02 + 0.3
1 µA
20 MΩ
1 kΩ
0.25 + 1
0.02 + 0.3
100 nA
200 MΩ
10 kΩ
0.30 + 1
0.02 + 0.3
10 nA
2 GΩ
100 kΩ
1.5 + 1
0.04 + 0.3
1 nA
20 GΩ
1 MΩ
1.5 + 1
0.04 + 0.1
1 nA
200 GΩ
10 MΩ
1.5 + 1
0.04 + 0.1
1 nA
Maximum Open Circuit Voltage: 300 V DC.
Preamp Settling Time (To 0.1% of final value with < 100 pF input capacitance): 2 kΩ through 20 MΩ: 15 ms; 200 MΩ 150 ms. (To 1% of final value with Input Guard on and < 1 pF of unguarded input capacitance): 2 GΩ: 10 ms; 20 GΩ: 100 ms; 200 GΩ: 1s.
Notes:
*: When properly zeroed.
IEEE-488 Bus Implemenation Specifications:
Multiline Commands: DCL, LLO, SDC, GET, GTL, UNT, UNL, SPE, SPD.
Uniline Commands: IFC, REN, EOI, SRQ, ATN.
Interface Functions: SH1, AH1, T5, TE0, L4, LE0, SR1, RL0, PP0, DC1, DT1, C0, E1.
Programmable Parameters: Function, Range, Zero Check, Zero Correct, Zero Suppress, EOI, Trigger, Terminator, 100-Reading Storage and Retrieval, Calibration, Display Format, SRQ, Status, Output Format.
Address Modes: TALK ONLY and ADDRESSABLE.
Trigger to Reading Done: 350 ms typical.
General Specifications:
Display: 4-1/4 digit numeric LEDs with appropriate decimal point and polarity indication; signed two-digit alphanumeric expoenent.
Overrange Indication: Display reads \"OL\".
Ranging: Automatic or manual.
Conversion Time: 330 ms.
Data Store and Min/Max: 100-reading store capacity; records data at one of six selectable rates from every reading to 1 reading/hour, or by manual triggering. Also detects and stores maximum and minimum readings continuously while in Data Store mode.
Programs: Provide front panel access to IEEE address, choice of engineering units or scientific notation, and digital calibration.
Maximum Input: 250 V peak, DC to 60 Hz sine wave; 10 s per minute maximum on mA ranges.
Maximum Common Mode Voltage (DC to 60 Hz sine wave): 500 V peak.
Isolation (Input LO to chassis): Typically 1010 Ω in parallel with 500 pF.
Input Connector: Three lug triaxial on rear panel.
Output Connectors: 5-way binding posts on rear panel for preamp and analog outputs. Rear panel BNC for External Trigger and Meter Complete.
2V Analog Output: 2 V for full range input. Inverting in Volts and Ohms modes. Output impedance 10 kΩ.
Preamp Output: Provides a guard output for Volts and Ohms measurements. Can be used as an inverting output or with external response in Amps and Coulombs modes. Ouput Impedance: 100 Ω.
Gain Error at Preamp Output: Typically 5 ppm.
Small Signal Bandwidth at Preamp Output: Typically -3 dB at 100 kHz.
External Trigger: TTL compatible External Trigger and Electrometer Complete.
V, Ω Guard Switch: OFF position: Inner shield of triax is Input LO, input capacitance is < or = to 20 pF. ON position: Inner shield of triax is Guard (follows input HI). Input capacitance is < or = to 2 pF. Use Analog Output COM for Input LO connection.
Environment:
Operating: 0° - 50°C; relative humidity 70% non-condensing, up to 35°C.
Storage: -25° - +65°C.
Warm-Up: 2 hours to rated accuracy.
Power: 105 - 125 V or 210 - 250 V (internal switch selected), 90 - 110 V available, 50 - 60 Hz, 15 VA.
Dimensions: 127 mm H x 216 mm W x 359 mm D (5\" x 8.5\" x 14.125\")
Weight: 3.2 kg (7 lbs.)
For Domestic Customers: Packaging, handling, and order processing included in shipping in all domestic shipments as quoted by the shipping calculator. For International Customers there is a $25.00 minimum for packaging, handling, and order processing. International shipping to be determined by destination.
Prior to shipment I will need to know the following information (filled out on a form that I will send you) for International Customers or Packages/Freight being Forwarded internationally. International customers may also be subject to a freight forwarder form if applicable.:
(1) Are you the end-user of this item?
(2) If you are not the ultimate end-user of the item, please state the ultimate end user\'s name.
(3) What is the ultimate country destination?
03/10/15
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.