*DISCONTINUED*
Specifications
Model
SL-C08H
Effective aperture angle
Max. ±2.5° (when operating distance is at least 3 m9.8\')
Response time
15 ms*1
Light source
Infrared LED (850 nm)
Detection capability
ø25 mm (when the blanking function is not used)
Operation mode
Turned on when light is being applied to all optical axes (excluding when the blanking function is used)
No. of beam axes
8
Detection zone
140 mm5.51\"
Protection area
185 mm7.283\"
0.3 to 9 m
Operating distance/Beam width
0.3 to 9 m0.98\' to 29.5\'
Beam axis interval
20 mm0.79\"
Lens diameter
5 mm0.20\"dia.
OSSD output
Output type
2 outputs each for PNP and NPN, Can be switched using the connection connector cable
Max. load current
300 mA*2
OFF-state voltage
2.5 V (with a cable length of 7 m23.0\')
Leakage current
100 µA maximum*3
Max. capacitive load
2.2 µF (with a load resistance of 100 Ω)
Load wiring resistance
2.5 Ω maximum*4
Approved standards
EMC
EMS
UL61496-1
EMI
FCC Part15 Class A
Safety
UL61496-1 (type 4 ESPE), UL61496-2 (type 4 AOPD),UL508
Current consumption
Transmitter
55 mA
Receiver
67 mA
Rating
Power voltage
24 VDC ±10 %, Ripple (P-P) 10 % or less
Environmental resistance
Enclosure rating
IP65 (IEC60529)
Ambient light
Incandescent lamp: 5,000 lux or less, Sunlight: 20,000 lux or less
Operating ambient temperature
-10 to +55 °C14 to 131 °F(No freezing)
Storage temperature
-10 to +60 °C14 to 140 °F(No freezing)
Operating relative humidity
35 to 85 % RH (No condensation)
Storage relative humidity
35 to 95 % RH (No condensation)
Vibration resistance
10 to 55 Hz, Double amplitude 0.7 mm0.03\", 20 sweeps in each of the X, Y, and Z directions
Shock resistance
100 m/s2(Approx. 10 G), 16 ms pulse, 1,000 times in each of the X, Y, and Z directions
Material
Main unit case
Aluminum
Upper case/lower case
Zinc die-cast
Front cover
Polycarbonate
Weight
Transmitter
Approx 165 g
Receiver
Approx 180 g
PLEASE CHECK OUR OTHER ITEMS FOR SALE AND CONTACT US FOR A DISCOUNT ON MULTIPLE PURCHASES!
Our items are excess inventory acquired from company mergers, closures and laboratory acquisitions.
We have a warehouse full of new and used business and laboratory equipment, electronics, motors, measuring devices, consumables, etc. that we’re slowly adding to our page.
We’ll be happy to send you anExcel sheetwith all current inventory.
We try our best to provide an accurate description of each item we list but please contact us if you have any questions at all before purchase.Items have not been tested, unless otherwise stated.
If there are multiple quantities of an item listed, the item you receive might not be the exact one in the picture above.
Important disclaimer: You are buyingitems which can be used in chemical and laboratory processes which are potentially dangerous. It is your sole responsibility as the buyer to judge the safety of a given procedure and to assess the compatibility of any lab items with the given procedure and as such the seller shall not be held liable for damage, injury, or any other loss that may occur from the use of any product purchased.By your purchase of this item you are agreeing to hold harmless the Seller and in any event of accident, injury, damage, or loss that may arise, under any circumstance, from use of said items. Please inspect all equipment for damage upon receipt and prior to use. We can offer no warranties, expressed or implied, as to the suitability of these products for any given use.
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.