EF Johnson Viking Ranger , #24
SN: 82365
Rebuild complete
This Ranger I was, initially, wiring version I. This version did not feature keyer or modulator bias circuitry. New wiring and modules will be incorporated into the rebuild, making this a Ranger wiring version II We will install new solid state driver PTT module, solid state driver, keyer/bias sub panel,( featuring the OEM Johnson Keyer as well as adjustable Modulator Tube bias, solid state VFO +150V regulator, Solid state +300V regulator, combined terminal strips for decreased wiring complexity. For sale:
Johnson Viking Ranger SN: 82365
* The re-build altered this Ranger from wiring version 1 ( no keyer and fixed Modulator bias) to wiring version 2 ( Keyer, Adjustable Modulator tube bias and other functional operational features). * Overhaul/rebuild complete* Photos posted as rebuild progresses* Initial tear-down in process* Ranger stripped to chassis* Some mechanical work started* Disassembled band switch input collar/shaft bearing assembly ( band switch was frozen), cleaned and re-lubricated. This process included removing the band-switch shaft spacing lock ring ( re-installed after lubrication process completed).
***** NOTE: We recommend, every 6 months, ALL shaft bearings & shaft collars be lubricated with a light machine oil ( sewing machine oil is fine). We suspect this Ranger was taken out of service because the band switch bearing had frozen.* Chassis cleaning and water washing completed.* Mechanical work started* 4 pin jones female receptacle installed* Male IEC panel connector installed* Mode Switch of Death opening edges insulated with rubber \"U\" edging. This prevents any possible interconnect wiring damage.
* All new ( or refurbished) tube sockets and terminal strips installed.* Power transformer installed ( not yet wired in)* Bottom of chassis re-wiring and rebuild 75% complete
* Top of chassis re-wiring and rebuild 68% complete* New mil grade meter switch installed* Interface wiring for new Bias/Keyer panel installed.
* AC Line fuse installed on rear panel* Circuit jumper socket installed, partially wired in* Circuit jumper socket interface wiring completed* AC Line filter components installed* RF input circuit components installed* VFO/XTAL switch interface wiring in process* PA Mil grade ceramic tube socket interface wiring complete* Mode Switch of Death interface wiring complete* Keyer/Adjustable Modulator tube bias panel installation started* LV B+ (300V) interface wiring re-work completed* VFO/XTAL Switch interface wiring completed.
* Panel Lamp & \"Phone active\" lamp wiring installed.
* New meter switch interface wiring installed* Tube heater (6.3VAC) circuit tested. Mode switch AC portion tested* Keyer/adjustable bias sub panel interface wiring completed* PTT Module installed, interface wiring not started.
* PTT module interface wiring installed* PTT module built in test switch test ok.* Installed Aux Loading switch* Installed Loading Capacitor* Installed OEM microphone connector* Installed PA tuning capacitor* Panel Progress: Panel stripped, primed, (three coats), Johnson Dark Grey ( three coats). Once the Dark Grey has cured, the Johnson Maroon center section will receive three coats, then once that has cured, the panel will be re-lettered.* Panel complete.* Under-chassis wiring approximately 98% complete* Top of Chassis wiring approximately 98% complete* PA components installed
* Temporary panel meter installed* Circuit metering parameters tested, OK* +300V solid state buss regulator installed and tested* LV Filter choke installed* HV Filter capacitor/bleeder assembly installed* Top-of-chassis shield installed.
* Adjustable modulator bias circuit tested* Keyer tested* XTAL circuit tested with shop crystal* Rear panel PTT, mic input and key circuits installed.* Overhauled VFO & VFO shroud installed and tested.
* Newly painted & decaled front panel installed ( See Photos). Cabinet not yet shown in photos.* Cleaned & clear-coated knobs installed* VFO bezel, dial, & VFO ball drive snubber assembly installed and tested.* Power, modulation & VFO Calibration tests.* Panel & meter lamps tested.* Modulation tubes idle IP set (55ma)* No International Shipping. Lower 48 USA only. Shipping via Fed Ex, Double Box, Insured for sales value. This unit, double boxed, is calculated by Fed Ex ( because of the dimensions of the outer carton) to weigh 100#. Because of the value of the shipment, an adult signature is REQUIRED.
* PLEASE DO NOT MAKE A PAYMENT, upon purchase, until we send you and invoice. This ensures an accurate shipping calculation.* All Sales Final: No Warranties or Guarantees expressed or implied. No returns or exchanges.* Tech support via Email.* Pirate Shipping also available
* OPTION #1: 4 pin female Jones Socket in place of the OEM Crystal Socket 115V relay output connector. Male Plug not supplied. ( These are available on and other places on line).
* OPTION #2: IEC AC Panel male connector
****NOTE *** : Option 1 & 2 installed in this unit.* All sales final, no returns or exchanges. No warranties or guarantees expressed or implied.* Band plan for this unit is: `160,80,40,20,15,10.... 11 meters disabled..
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.