IFM PN2294 Vacuum Pressure Sensor

IFM PN2294 Vacuum Pressure Sensor
$499.00

Buy Now

IFM PN2294 Vacuum Pressure SensorProduct characteristicsNumber of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1Measuring range-1...10 bar-14.6...145 psi-100...1000 kPa-0.1...1 MPaProcess connectionthreaded connection 1/4\" NPT Internal threadApplicationSystemgold-plated contactsMeasuring elementceramic-capacitive pressure measuring cellApplicationfor industrial applicationsMedialiquids and gasesMedium temperature [°C]-25...80Min. bursting pressure150 bar2175 psi15 MPaPressure rating75 bar1087 psi7.5 MpaVacuum resistance [mbar]-1000Type of pressurerelative pressure; vacuumMAWP (for applications according to CRN)50 bar725 psi5 MPaElectrical dataOperating voltage [V]18...30 DC; (to SELV/PELV)Current consumption [mA]< 35Min. insulation resistance [MΩ]100; (500 V DC)Protection classIIIReverse polarity protectionyesPower-on delay time [s]0.3Integrated watchdogyesInputs / outputsNumber of inputs and outputsNumber of digital outputs: 2; Number of analog outputs: 1OutputsTotal number of outputs2Output signalswitching signal; analog signal; IO-Link; (configurable)Electrical designPNP/NPNNumber of digital outputs2Output functionnormally open / closed; (configurable)Max. voltage drop switching output DC [V]2Permanent current rating of switching output DC [mA]250Switching frequency DC [Hz]< 500Number of analog outputs1Analog current output [mA]4...20; (scalable 1:5)Max. load [Ω]500Analog voltage output [V]0...10; (scalable 1:5)Min. load resistance [Ω]2000Short-circuit protectionyesType of short-circuit protectionyes (non-latching)Overload protectionyesMeasuring/setting rangeMeasuring range-1...10 bar-14.6...145 psi-100...1000 kPa-0.1...1 MPaAnalog start point-1...8 bar-14.6...116 psi-0.1...0.8 MPaAnalog end point1...10 bar14.6...145 psi0.1...1 MPaFactory setting / CMPT = 2Set point SP-0.94...10 bar-13.6...145 psi-0.094...1 MPaReset point rP-0.98...9.96 bar-14.2...144.4 psi-0.098...0.996 MPaMin. difference between SP and rP0.06 bar0.6 psi0.006 MPaIn steps of0.02 bar0.2 psi0.002 MPaStatus_B High Resolution / CMPT = 3Set point SP-0.94...10 bar-13.6...145 psi-0.094...1 MPaReset point rP-0.98...9.96 bar-14.2...144.4 psi-0.098...0.996 MPaMin. difference between SP and rP0.06 bar0.6 psi0.005 MPaIn steps of0.01 bar0.1 psi0.001 MPaAccuracy / deviationsSwitch point accuracy [% of the span]< ± 0,4; (Turn down 1:1)Repeatability [% of the span]< ± 0,1; (with temperature fluctuations < 10 K; Turn down 1:1)Characteristics deviation [% of the span]< ± 0,25 (BFSL) / < ± 0,5 (LS); (Turn down 1:1; BFSL = Best Fit Straight Line; LS = limit value setting)Hysteresis deviation [% of the span]< ± 0,1; (Turn down 1:1)Long-term stability [% of the span]< ± 0,05; (Turn down 1:1; per 6 months)Temperature coefficient zero point [% of the span / 10 K]< ± 0,2; (-0...80 °C)Temperature coefficient span [% of the span / 10 K]< ± 0,2; (-0...80 °C)Notes on the accuracy / deviationswitch point accuracy, linearity error under DNV GL: < ± 1%: < ± 1%Reaction timesResponse time [ms]< 1.5Delay time programmable dS, dr [s]0...50Damping process value dAP [s]0...4Damping for the analog output dAA [s]0...4Max. response time analog output [ms]3Software / programmingParameter setting optionshysteresis / window; normally open / closed; switch-on/switch-off delay; Damping; Display unit; current/voltage outputInterfacesCommunication interfaceIO-LinkTransmission typeCOM2 (38,4 kBaud)IO-Link revision1.1SDCI standardIEC 61131-9SIO modeyesRequired master port classA; (when pin 2 not connected: B)Supported DeviceIDsType of operationDeviceIDFactory setting / CMPT = 2473Status_B High Resolution / CMPT = 3989NoteFor further information please see the IODD PDF file at \"Downloads\"Factory setting / CMPT = 2ProfilesSmart Sensor: Process Data Variable; Device Identification, Device DiagnosisMin. process cycle time [ms]2.3IO-Link resolution pressure [bar]0.01IO-Link process data (cyclical)Functionbit lengthpressure14binary switching information2IO-Link functions (acyclical)application specific tagStatus_B High Resolution / CMPT = 3ProfilesSmart Sensor ED2: Digital Measuring Sensor (0x000A), Identification and Diagnosis (0x4000)Min. process cycle time [ms]3IO-Link resolution pressure [bar]0.005IO-Link process data (cyclical)Functionbit lengthpressure16device status4binary switching information2IO-Link functions (acyclical)application specific tagOperating conditionsAmbient temperature [°C]-25...80Storage temperature [°C]-40...100ProtectionIP 65; IP 67Tests / approvalsEMCDIN EN 61000-6-2DIN EN 61000-6-3Shock resistanceDIN EN 60068-2-2750 g (11 ms)Vibration resistanceDIN EN 60068-2-620 g (10...2000 Hz)MTTF [years]138UL approvalUL approval numberJ012Pressure equipment directivesound engineering practice; can be used for group 2 fluids; group 1 fluids on requestMechanical dataWeight [g]223.5Materialstainless steel (1.4404 / 316L); PBT+PC-GF30; PBT-GF20; PCMaterials (wetted parts)stainless steel (1.4404 / 316L); Al2O3 (ceramics); FKMMin. pressure cycles100 millionTightening torque [Nm]> 50; (Depends on lubrication, seal and pressure rating)Process connectionthreaded connection 1/4\" NPT Internal threadRestrictor element integratedno (can be retrofitted)Displays / operating elementsDisplayDisplay unit3 x LED, green (bar, psi, MPa)Switching status2 x LED, yellowMeasured valuesalphanumeric display, red/green 4-digitRemarksPack quantity1 pcs.Electrical connectionConnectionConnector: 1 x M12; coding: A; Contacts: gold-plated

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design