Generac 7000 240V 50A Smart Management Module (SMM)
$79.99

About this itemFuel TypeNo FuelPower SourceManualRecommended Uses For ProductResidentialVoltage240 volts_of_alternating_currentAdditional FeaturesLED IndicatorEngine Type4 StrokeIgnition System TypeElectronicEngine Displacement418 cubic centimetersTotal Power Outlets1Current Rating50 AFrequency50 hertzRuntime50 minutes - UNIVERSAL STANDBY GENERATOR COMPATIBILITY: Works with any single-phase 240V home standby generator or PWRcell energy storage system — not limited to Generac brands — managing loads up to 50 resistive amps or 40 inductive amp
- SCALE UP TO 8 MODULES PER SYSTEM: Install up to eight individual 50A Load Managers on a single generator system, each assigned a unique priority, to protect and sequence multiple large appliances simultaneously without overloading
- NO CONTROL WIRES REQUIRED FOR OPERATION: Built-in frequency-sensing intelligence lets each module operate autonomously — no low-voltage control wires back to the transfer switch needed, reducing installation complexity and cost
- NEMA 3R ENCLOSURE FOR INDOOR OR OUTDOOR USE: Rated to withstand rain, sleet, and ice formation on the enclosure, this module can be mounted near the electrical panel or appliance in virtually any location — indoors or outdoors
- 8-LEVEL PRIORITY DIAL CONTROLS LOAD SEQUENCING: Set each module to a unique priority from 1 (first restored) to 8 (last restored) — lower numbers reconnect first after a shed event; each load must have its own number to avoid sequencing conflicts
- GENERATOR LOCKOUT BLOCKS NON-ESSENTIAL LOADS AUTOMATICALLY: Set any module to lockout mode to prevent that appliance from running under generator power; when utility power returns, the load restores automatically without manual intervention
- EXTERNAL LED STATUS DISPLAY FOR REAL-TIME DIAGNOSTICS: Five coded LED states — including load connected, load shed, 30-minute lockout, generator lockout, and no module power — let you diagnose system status without opening the electrical enclosure
- WHAT\'S INCLUDED AND WIRING REQUIREMENTS: Includes module, mounting hardware, and owner\'s manual; requires 8 AWG copper conductors rated for 50A; must be installed upstream of the appliance\'s circuit breaker by a qualified electrician