Free Userbar - Userbars - User Bar - User Bars
 
Advanced search
Registered users

Username:

Password:

Log me on automatically next visit?

¬ Forgot password
¬ Registration

» Upload Userbar
» Animate Userbar
» Userbars Tutorial
» Userbar Tournaments
» Forum
» Chat Room
» FAQ
» Links

• PC Cheat Codes

>> If you dont know how to design a userbar, then write here a Userbar that you want. >> If you know how to design them help these people and design what they request.




USERBARS.org | Free Forum Userbars

On eBay now
eBay

GM328A Transistor Tester Resistance Capacitance Inductance ESR Frequency Meter

GM328A Transistor Tester Resistance Capacitance Inductance ESR Frequency Meter
$12.86

Buy Now

Store CategoriesStore Categories
  • Product View

    Details

    Product features:Digital LCD display, easy to read, can display measurement data and graphicsRotary switch control, easy to use for key measurementPress and hold the test button to exit the frequency measurement function. The frequency measurement range is from 1Hz to above 1MHz. When the measured frequency is lower than 25KHz, the cycle is displayedSquare wave generator, with multi gear square wave frequency selectable. Rotate the left or right test button to switch to different square wave frequencies, and long press the test button to exit the square wave generatorPulse signal generator, turn left or right test button to adjust the pulse duty cycle from 1% to 99%. Press and hold the test button to exit the pulse signal generatorUse 5V Type-c power supply interface for power supply, and customers can also weld 9V battery interface for power supplyAutomatic shutdown, shutdown current is only about 20nANote: Before testing the capacitor, first discharge the capacitor, and then insert it into the test base for measurement, otherwise the microcontroller of the tester may be damaged.Input voltage: DC5VWorking voltage: about 30mA,Control of transistor testerThe tester is controlled by a rotary encoder switch,The rotary encoder switch can be operated in 6 ways: short press, long press, left rotation, right rotation, press and hold left rotation, press and hold right rotation.Press once in the shutdown state to turn on the power and start the test.If no device is detected after one test. Press and hold the switch or rotate the switch left and right to enter the function menu. After entering the function menu, the left or right switch can be selected above or below the menu item. To enter a function item, press the switch briefly. When you need to exit from a function, press and hold the switch.Calibration:The tester calibration is used to eliminate the error of its own components and make the final test results more accurate. Calibration is divided into quick calibration and full function calibration.Operation method for quick calibration: short circuit the three test points TP1, TP2 and TP3 with wires, then press the test button, and observe the screen at the same time. The screen color will become white on a black background, and the prompt message \"Selftest mode..?\" will appear After that, press the test button to enter the fast calibration process; If the prompt \"Self test mode..?\" appears After that, if no key is pressed within 2 seconds, a normal test process will be conducted, and the resistance values of the wires shorting TP1, TP2, and TP3 test points will be displayed finally. After entering the quick calibration process, some data will appear on the screen, regardless. Wait until a flashing string appears on the screen“isolate Probes!” After that, remove the wires shorting TP1, TP2 and TP3. The quick calibration is completed until the string \"Test End\" appears on the screen. For the first calibration, use the full function calibration mode.Full function calibration needs to be entered from the function menu, and another 220nf capacitor needs to be prepared. Full function calibration performs a more comprehensive calibration process and takes longer. After entering the function menu, turn the test button to the menu item \"Selftest\", and then press the test button to enter the full function calibration process. The flashing string \"short Probes!\" first appears on the screen, At this time, just like rapid calibration, use wires to short circuit the three test points and wait for the calibration process. The flashing string \"isolate probes!\" appears on the screen When the string \"1 - | | - 3>100nf\" appears on the screen, the prepared 220nf capacitor is installed on test points TP1 and TP3. Wait until the screen prompts \"Test End\", and the full function calibration process is completed.Package list:GM328A transistor tester X1
    • Shipping Policy
    • Payment Method
    • Returns Policy
    Shipping Policy


    Payment MethodReturns Policy
    • Home
    • Payment
    • About us
    • Contact class=\"navi-menu-list left\">
    • Home
    • Payment
    • About us
    • Contact us
    Store CategoriesStore Categories
    • Product View

      Details

      Product features:Digital LCD display, easy to read, can display measurement data and graphicsRotary switch control, easy to use for key measurementPress and hold the test button to exit the frequency measurement function. The frequency measurement range is from 1Hz to above 1MHz. When the measured frequency is lower than 25KHz, the cycle is displayedSquare wave generator, with multi gear square wave frequency selectable. Rotate the left or right test button to switch to different square wave frequencies, and long press the test button to exit the square wave generatorPulse signal generator, turn left or right test button to adjust the pulse duty cycle from 1% to 99%. Press and hold the test button to exit the pulse signal generatorUse 5V Type-c power supply interface for power supply, and customers can also weld 9V battery interface for power supplyAutomatic shutdown, shutdown current is only about 20nANote: Before testing the capacitor, first discharge the capacitor, and then insert it into the test base for measurement, otherwise the microcontroller of the tester may be damaged.Input voltage: DC5VWorking voltage: about 30mA,Control of transistor testerThe tester is controlled by a rotary encoder switch,The rotary encoder switch can be operated in 6 ways: short press, long press, left rotation, right rotation, press and hold left rotation, press and hold right rotation.Press once in the shutdown state to turn on the power and start the test.If no device is detected after one test. Press and hold the switch or rotate the switch left and right to enter the function menu. After entering the function menu, the left or right switch can be selected above or below the menu item. To enter a function item, press the switch briefly. When you need to exit from a function, press and hold the switch.Calibration:The tester calibration is used to eliminate the error of its own components and make the final test results more accurate. Calibration is divided into quick calibration and full function calibration.Operation method for quick calibration: short circuit the three test points TP1, TP2 and TP3 with wires, then press the test button, and observe the screen at the same time. The screen color will become white on a black background, and the prompt message \"Selftest mode..?\" will appear After that, press the test button to enter the fast calibration process; If the prompt \"Self test mode..?\" appears After that, if no key is pressed within 2 seconds, a normal test process will be conducted, and the resistance values of the wires shorting TP1, TP2, and TP3 test points will be displayed finally. After entering the quick calibration process, some data will appear on the screen, regardless. Wait until a flashing string appears on the screen“isolate Probes!” After that, remove the wires shorting TP1, TP2 and TP3. The quick calibration is completed until the string \"Test End\" appears on the screen. For the first calibration, use the full function calibration mode.Full function calibration needs to be entered from the function menu, and another 220nf capacitor needs to be prepared. Full function calibration performs a more comprehensive calibration process and takes longer. After entering the function menu, turn the test button to the menu item \"Selftest\", and then press the test button to enter the full function calibration process. The flashing string \"short Probes!\" first appears on the screen, At this time, just like rapid calibration, use wires to short circuit the three test points and wait for the calibration process. The flashing string \"isolate probes!\" appears on the screen When the string \"1 - | | - 3>100nf\" appears on the screen, the prepared 220nf capacitor is installed on test points TP1 and TP3. Wait until the screen prompts \"Test End\", and the full function calibration process is completed.Package list:GM328A transistor tester X1
      • Shipping Policy
      • Payment Method
      • Returns Policy
      Shipping Policy

      We will arrange shipping for you within 24 Hours after payment cleared except the holidays.

      -We ship items to Worldwide. Thank you!

      -we will ship out the order in 1-2 business days after payment cleared .Since it is international shipping ,delivery time is about 15--28 business days to arrive to most countries.

      Payment Method

      We accept PayPal payment ONLY, and must be received within 5 days from the date of purchase.

      2. It is easy and safe for you to pay by credit cards, debit cards, bank transfers and PayPal account balances.

      3.Buyers are responsible for import duties,custom fees and taxes, if any, please check your country.

      Returns Policy

      1.We believe our items are so outstanding. We are convinced you will be happy with your Purchase.

      2. If you do not satisfy with our items. Please simply return to us within 30 Days in original condition. Just pay for the returned postage. Then we can issue full refund or resend the item to you after the returned item arrived at our warehouse.

      3. Please include your ID and item number with any email requests.

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design