Fluke 8050A Digital Multimeter
$50.00

Fluke 8050A Opts: No Options Avalon Object#:30004332,30004334
The Fluke Model 8050A Digital Multimeter provides superior performance and measurement capabilities in a low cost, benchtop instrument. These 4 1/2 digit DMMs have the following measurement functions: DC volts, true rms AC volts, DC amps, true rms AC amps, ohms, dBm (with selectable reference impedance#039;s) conductance, and diode test. They also have a relative-reference feature that works with all measurement functions. These units also feature 0.03% basic dc accuracy and true rms from 20 Hz to 50 kHz. They also have overload protection. Rechargeable batteries are available in the model 8050-01 otherwise the 8050A operates on AC line power only. Option:No Options - TypePortable
- Digits/Count4½
- Vdc Low Range10 µV
- Vdc High Range1 kV
- Basic Vdc Accuracy0.03% +2 digits (for one year)
- StatusDiscontinued by Manufacturer
The Fluke8050Ais a portable benchtop digital multimeter with a 4½ digit LCD. - Voltage: 10 µV to 1000 VDC, 10 mV to 750 VrmsAC
- Current: 10 nA to 2ADC, 10 µA to 2 ArmsAC
- Resistance: 10 mΩ to 20 MΩ
- Conductance: Up to 100,000 MΩ
- Voltage measurements in decibels, which can be referenced to one of 16 user selected reference impedances
- Diode and transistor measurements
- Ability to store any input signal as an offset or relative reference value
- Automatic polarity indication and overrange indication
- Protection from overloads and protection from transients of up to 6 kV, 10 µs
- Dual-slope integration a/d conversion to ensure noise-free measurements
- DC voltage
- Input impedance: 10 MΩ in parallel with <100 pF
- Normal mode rejection ratio: >60 dB
- Common mode rejection ratio: >90 dB
- Common mode voltage (maximum): 500 VDC or peak AC
- Maximum input: 1000 VDC or peak AC
- AC voltage
- Common mode rejection ratio: >60 dB
- Crest factor range: Waveforms with a Peak/RMS ration of 1:1 to 3:1 at full scale, increasing down range
- Input impedance: 10 MΩ in parallel with <100 pF
- Maximum input: 750 Vrms or 1000 Vpeak
- Overload protection: 500 VDC/ACrms