Fluke 435 Power QualityAnalyzer meter helps you locate,predict, prevent and troubleshoot problems in power distribution systems. Theseeasy-to-use power quality tools are a “must have” for any person who maintainsor troubleshoots three phase power. The new IEC Class A standards for flickerand power quality are built right in to take the guess work out of powermonitoring.
- Troubleshoot real-time: Analyze the trends using the cursors and zoom tools-even while background recording continues
- Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance
- Automatic Transient Mode: Capture 200 kHz waveform data on all phases simultaneously up to 6 kV
- Fully Class-A compliant: Conduct tests according to the stringent international IEC 61000-4-30 Class-A standard
- Measure all three phases and neutral: With included four current probes
- AutoTrend: Every measurement you see is always automatically recorded, without any setup
- System-Monitor: Up to ten power quality parameters on one screen according to EN50160 power quality standard
- Inrush mode: For troubleshooting nuisance circuit breaker tripping
- View graphs and generate reports: With included analysis software
- Logger function: Configure for any test condition with memory for over 400 parameters at user defined intervals
- Mains signaling: Measure interference from ripple control signals at specific frequencies
- Battery Life: Seven hours operating time per charge on NiMH battery pack
Applications
- Frontline troubleshooting – quickly diagnose problems on-screen to get your operation back online
- Predictive maintenance – detect and prevent power quality issues before they cause downtime
- Quality of service compliance – validate incoming power quality at the service entrance
- Long-term analysis – uncover hard-to-find or intermittent issues
- Load studies – verify electrical system capacity before adding loads
- Energy assessments – quantify energy consumption before and after improvements to justify energy saving devices
Features:
- Complete three-phase troubleshooting tool: measures virtually every power system parameter: voltage, current, frequency, power, power consumption (energy), unbalance and flicker, harmonics and inter-harmonics. Captures events like dips and swells, transients, interruptions and rapid voltage changes.
- The Fluke 435 features 0.1 percent voltage accuracy making it fully compliant with the IEC 61000-4-30 Class A standard
- Logger function: record the detail you need. Detailed, user-configurable long-time recording gives you the MIN, MAX and AVG readings of up to 100 parameters on all 4 phases with selectable averaging time down to 0.5 seconds. Enough memory is available to record 400 parameters with 1 minute resolution for up to a month.
- Four channels: simultaneously measures voltage and current on all three phases and neutral.
- Auto Scaling: easier trend analysis with automatic scaling of the vertical axis you will always use the full display to view the waveforms.
- Automatic transient display: captures up to 40 dips, swells, interruptions or transients automatically.
- Meets the stringent 600 V CAT IV, 1000 V CAT III safety standard required for measurements at the service entrance.
- Rugged, handheld instrument operates for more than 7 hours on included rechargeable NiMH battery pack. Menu-driven interface simplifies operation.
- Extensive data analysis possibilities. Cursors and zoom can be used ‘live’ while taking the measurements, or ‘offline’ on stored measurement data. The stored measurements can also be transferred to a PC with FlukeView software.
- The Fluke 435 comes with Power log software to analyze recorded data and to create reports.
- Complies with IEC 61000-4-30 measurement standards
435
434*
Measures voltage, current, dips, swells, interruptions,
harmonics, inter-harmonics, flicker, power, energy,
transients, frequency, unbalance, inrush, EN50160 overview
•
•
Logger function with multi-parameter logging
•
optional*
Mains signaling
•
optional*
Memory size
16 MB
8 MB
Current probes
3000 A flexible
(4)
40 A/400 A
clamp (4)
Carrying case
water-tight hard
case with rollers
rugged hard case
Software
Fluke Power Log
and FlukeView®
FlukeView®
Technical Data
Inputs
Number:
4 voltage and current (3 phases + neutral)
Maximum voltage:
1000 Vrms (6 kV peak)
Maximum sampling speed:
200 kS/s on each channel simultaneously
Volt/Amps/Hertz
Vrms (AC + DC)
Measurement range:
1 ... 1000 V
Accuracy:
0.1% of Vnom
Vpeak
Measurement range:
1 ... 1400 V
Accuracy:
5% of Vnom
Crest factor, voltage
Measurement range:
1.0 ... > 2.8
Accuracy:
±5%
Arms (AC + DC)
Measurement range:
0 ... 20 kA
Accuracy:
±0.5% ± 5 counts
Apeak
Measurement range:
0 ... 5.5 kA
Accuracy:
5%
Crest factor, A
Measurement range:
1 ... 10
Accuracy:
±5%
Hz 50 Hz nominal
Measurement range:
40 ... 70 Hz
Accuracy:
±0.01 Hz
Dips and swells
Vrms (AC+DC) ²
Measurement range:
0.0% … 100% of Vnom
Accuracy:
±0.2% of nominal voltage
Arms (AC+DC) ²
Measurement range:
0 ... 20 kA
Accuracy:
±1% ± 5 counts
Harmonics
Harmonic (interharmonic) (n)
Measurement range:
DC, 1..50; (Off, 1..49) measured according to IEC 61000-4-7
Vrms
Measurement range:
0.0 … 1000 V
Accuracy:
±0.05% of nominal voltage
Arms
Measurement range:
0.0 … 4000 mV x clamp scaling
Accuracy:
±5% ± 5 counts
Watts
Measurement range:
Depends on clamp scaling and voltage
Accuracy:
±5% ± n x 2% or reading, ± 10 counts
DC voltage
Measurement range:
0.0 … 1000 V
Accuracy:
±0.2% of nominal voltage
THD
Measurement range:
0.0 … 100.0%
Accuracy:
±2.5% V and A (± 5% Watt)
Hz
Measurement range:
0 … 3500 Hz
Accuracy:
± 1 Hz
Phase angle
Measurement range:
-360º ... +360º
Accuracy:
± n × 1.5º
Power and energy
Watt, VA, VAR
Measurement range:
1.0 … 20.00 MVA¹
Accuracy:
±1% ± counts
kWh, kVAh, kVARh
Measurement range:
00.00 …200.0 GVAh¹
Accuracy:
± 1.5% ± 10 counts
Power Factor/ Cos Ф / DPF
Measurement range:
0…1
Accuracy:
± 0.03
Flicker
Pst (1 min), Pst, Plt, PF5
Measurement range:
0.00 … 20.00
Accuracy:
±5%
Unbalance
Volts
Measurement range:
0.0 … 5.0%
Accuracy:
±0.5%
Current
Measurement range:
0.0 … 20%
Accuracy:
± 1%
Transient Capture
Volts
Measurement range:
±6000 V
Accuracy:
±2.5% of Vrms
Minimum detect duration
5 µs (200kS/s sampling)
Inrush mode
Arms (AC+DC)
Measurement range:
0.000 … 20.00 kA¹
Accuracy:
±1% of meas ± 5 counts
Inrush duration (selectable)
Measurement range:
7.5 s ... 30 min
Accuracy:
±20 ms (Fnom = 50 Hz)
Autotrend recording
Sampling:
5 readings/sec continuous sampling per channel
Memory:
1800 min, max and avg points for each reading
Recording time:
Up to 450 days
Zoom:
Up to 12x horizontal zoom
Memory
Screens & data:
50, shared memory divided between logging, screens and data sets
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.