|
>> If you dont know how to design a userbar, then write here a Userbar that you want.
>> If you know how to design them help these people and design what they request.
|
 |
 |
USERBARS.org | Free Forum Userbars
| On eBay now |
Fluke 375 FC True RMS Clamp Meter Multimeter w/ Carrying Case CAT III/IV
$200.00

I bought this new in August 2026 but with another style meter. It has an ink mark where I marked out my name it’s in the pic. Other than that it’s like brand new I used it about 10 since I bought it. No manual but you can download load it from fluke if you want it.Key featuresHigh performance clamp meter that measures very low voltage and high resistanceTransmits measurements to your smartphone via Fluke Connect® so you can view them at a safer distanceMeasures AC and DC current to 600 A, and AC and DC voltage to 1000 VMeasures AC current to 2500 A AC with optional iFlex flexible current probeRead lessDownload the product manualDownload the data sheetIn stock$608.99Save 15% with codeFLUKE-15-CUSTOMERFAVESFREE ShippingArrives by Thursday, Dec 0330-day ReturnsSee all modelsFind a retailerYou might also likeFluke 376 FC True-RMS Clamp Meter with iFlex$699.9962 MAX+ Handheld Infrared Laser ThermometerFluke insulated screwdriver kitFluke insulated screwdriver kit$183.99Product overviewSpecificationsSpecifications: Fluke 375 FC True-RMS AC/DC Clamp MeterGeneral SpecificationsAC Current via JawRange 600.0 AResolution 0.1 AAccuracy 2% ±5 digits (10 Hz to 100 Hz)2.5% ±5 digits (100-500 Hz)Crest Factor (50 Hz/60 Hz) 3 @ 500 A2.5 @ 600 AAdd 2% for C.F. >2AC Current via Flexible Current ProbeRange 2500 AResolution 0.1 A (≤ 600 A)1 A (≤ 2500 A)Accuracy 3% ±5 digits (5 – 500 Hz)Crest Factor (50/60Hz) 3.0 at 1100 A2.5 at 1400 A1.42 at 2500 AAdd 2% for C.F. > 2Position SensitivityFlexible current probe i2500-10 Flex i2500-18 FlexA Distance from Optimum 0.5 in (12.7 mm) 1.4 in (35.6 mm)Error ±0.5 % ±0.5 %B Distance from Optimum 0.8 in (20.3 mm) 2.0 in (50.8 mm)Error ±1.0 % ±1.0 %C Distance from Optimum 1.4 in (35.6 mm) 2.5 in (63.5 mm)Error ±2.0 % ±2.0 %Measurement uncertainty assumes centralized primary conductor at optimum position, no external electrical or magnetic field, and within operating temperature range.DC CurrentRange 600.0 AResolution 0.1 AAccuracy 2% ±5 digitsAC VoltageRange 1000 VResolution 0.1 V (≤600.0 V)1 V (≤1000 V)Accuracy 1.5% ±5 digits (20 Hz to 500 Hz)DC VoltageRange 1000 VResolution 0.1 V (≤600.0 V)1 V (≤1000 V)Accuracy 1% ±5 digitsmV dcRange 500.0 mVResolution 0.1 mVAccuracy 1% ±5 digitsFrequency via JawRange 5.0 Hz to 500.0 HzResolution 0.1 HzAccuracy 0.5% ±5 digitsTrigger level 5 Hz to 10 Hz, ≥10 A10 Hz to 100 Hz, ≥5 AFrequency via Flexible Current ProbeRange 5.0 Hz to 500.0 HzResolution 0.1 HzAccuracy 0.5% ±5 digitsTrigger level 5 Hz to 20 Hz, ≥25 A20 Hz to 100 Hz, ≥20 A100 Hz to 500 Hz, ≥25 AResistanceRange 60 kΩResolution 0.1 Ω (≤600 Ω)1 Ω (≤6000 Ω)10 Ω (≤60 kΩ)Accuracy 1% ±5 digitsCapacitanceRange 1000 μFResolution 0.1 μF (≤ 100 μF)1 μ F (≤ 1000 μF)Accuracy 1% ±4 digitsMechanical SpecificationsMaximum voltage between any terminal and earth ground 1000 VBatteries 2 AA, NEDA 15A, IEC LR6Operating temperature -10 °C to +50 °CStorage temperature -40 °C to +60 °COperating humidity -non-condensing (< 10°C) ≤90% RH (at 10 °C to 30 °C)≤75% RH (at 30 °C to 40 °C)Operating altitude 3000 mStorage altitude 12,000 mSize (L x W x H) 249 x 85 x 45 mmWeight 395 gJaw opening 34 mmFlexible current probe diameter 7.5 mmFlexible current probe cable length(head to electronics connector) 1.8 mSafety IEC 61010-1, Pollution Degree 2IEC 61010-2-032: CAT III 1000 V / CAT IV 600 VIP rating IEC 60529: IP30, non-operatingRadio Frequency Certification FCC ID T68-FBLE IC:6627A-FBLEElectromagnetic Compatibility (EMC)International IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2CISPR 11: Group 1, Class AGroup 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself.Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purpose. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. Emissions that exceed the levels required by CISPR 11 can occur when the equipment is connected to a test object.Korea (KCC) Class A Equipment (Industrial Broadcasting & Communication Equipment)Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes.USA (FCC) 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103.Temperature coefficients Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.
|
|
|
 |
 |
|