Fluke 1732 Three Phase Electrical Energy Power Logger Analyzer

Fluke 1732 Three Phase Electrical Energy Power Logger Analyzer
$4,199.00

Buy Now

template

align=\"left\">




  • Fluke 1732 Three-Phase Electrical Energy Power Logger Analyzer (BC# 41481-L/T*)
  • (3) Fluke iFlex 1500-12 Cables
  • USB PC Interface Cable
  • Power Cord
  • Carrying Case w/ Strap



BE SURE TO CHECK OUR store FOR OTHER ITEMS!

This Item Has A Current Calibration!


Fluke 1732 Three-Phase Electrical Energy Power Logger

Discover when and where energy in your facility is being consumed; from the service entrance to individual circuits.

Includes Carrying Case & Accessories As Listed Above!

 

 

Working Condition: Yes
Warranty:  1 YEAR 1732 Three Phase Electrical Energy Logger

 

Energy logging is now within your reach—discover where you’re wasting energy, optimize your facility’s energy use and reduce your bill

The new Fluke 1732 and 1734 Three-Phase Electrical Energy loggers introduce a new simplicity to discovering sources of electrical energy waste. Discover when and where energy in your facility is being consumed; from the service entrance to individual circuits. Access and share data remotely with your team via the Fluke Connect® app so you can maintain safer working distances and make critical decisions in real-time, reducing the need for protective equipment, site visits and check-ins.

Profiling energy usage across your facility helps you identify opportunities for energy savings, and provides you with the data you need to act on them. The new Energy Analyze software package allows you to compare multiple data points over time to build a complete picture of energy usage, which is the first step to reduce the cost of your energy bill.

  • Measure all three phases: With included 3 flexible current probes.
  • Comprehensive logging: More than 20 separate logging sessions can be stored on the instruments. In fact, all measured values are automatically logged so you never loose measurement trends. They can even be reviewed during logging sessions and before downloading for real-time analysis.
  • Optimized user interface: Quick, guided, graphical setup ensures you’re capturing the right data every time, and the intelligent verification function indicates correct connections have been made, reducing user uncertainty
  • Bright, color touch screen: Perform convenient in-the-field analysis and data checks with full graphical display.
  • Optimized user interface: Capture the right data every time with quick, guided, graphical setup and reduce uncertainty about your connections with the intelligent verification function
  • Complete “in-the-field” setup through the front panel or Fluke Connect: No need to return to the workshop for download and setup or to take a computer to the electrical panel.
  • Fully integrated logging: Connect other Fluke Connect devices to the Fluke 1734 to simultaneously log up to two other measurement parameters, virtually any parameter available on a Fluke Connect wireless digital multimeter or module.*
  • Energy Analyze Plus application software: Download and analyze every detail of energy consumption with our automated studies: Discover how much energy individual pieces of equipment are consuming when they are operating at minimum and maximum capacity. Check capacity of circuits prior to adding additional loads (various standards exist for this process; in the US the NEC 220- 87 is the recommended standard). Load studies can also identify situations where you may be exceeding the allowable load on the circuit or when an agreed peak demand applies from the utility. For convenience, some load studies simply measure current which makes installation of the measuring equipment quick and easy. It is often recommended that load surveys be performed for 30 days so that all typical load conditions are encountered during the test.

    Energy assessments: quantify energy consumption before, and after improvements, to justify energy saving devices

    Energy surveys: Users often ask where measurements should be taken for an energy survey. The answer is multiple points within the facility. Start at the main service feeders; compare the power and energy measured here with the readings from the utility meter to ensure you’re receiving the correct charges. Then move downstream to the larger loads; these should be easy to identify by the current rating of the electrical panels downstream of the service entrances. Measuring at many points will allow a full picture of energy usage across the facility to be developed. The next question users typically have is how long an energy survey should last. This of course depends on the facility, but it is recommended that you measure for a period that matches a typical facility activity period. If the facility operates over a five day work week with down time on the weekend, a seven day survey will most likely capture typical conditions. If the facility operates Applications at a constant level for 24 hours a day, 365 days a year, a single day could be reasonably representative as long as you avoid a period where there may be planned maintenance.

    To capture a full picture of the facilities energy usage it is not necessarily required to have measurements made simultaneously at every consumption point in the facility. To get a comprehensive picture, spot measurements can be made and then compared on a sliding time timescale. For example, you could compare the service entrance results from a typical Tuesday between 6:00 am and 12:00 pm with those of a larger load in the facility. Typically there will be some correlation between these profiles.

    Logging related analog measurements: When conducting energy studies, it is useful to log related analog measurements such as temperature, voltage, current or pressure. These variables provide a better overall picture of operating conditions and allow you to correlate asset performance data with energy consumption. Correlating these variables provides more of the data you need to make cost saving performance adjustments. With the Fluke 1734, up to two Fluke Connect wireless modules can be used to capture these measurements, and the values will be automatically logged along with power and energy readings.

    Power and energy logging: When a piece of equipment is operated it instantaneously consumes a specific amount of power in watts (W) or kilowatts (kW). This power is accumulated over the operating time and expressed as energy consumed in kilowatt hours (kWh). Energy is what your electric utility charges for; there will be a standard charge from the utility per kilowatt hour. Utilities may have other additional charges, such as peak demand, which is the maximum power demand over a defined period of time, often 15 or 30 minutes. There may also be power factor charges, which are based on the effects of the inductive or capacitive loads in the facility. Optimizing peak demand and power factor often results in lower monthly electricity bills. The 1733 and Fluke 1734 Three Phase Electrical Energy loggers have the capability to measure and characterize these effects enabling you to analyze the results and save money.

    Simplified load studies: For situations where it’s either difficult or impractical to make a voltage connection the simple load study feature allows users to perform a simplified load study by measuring current only. The user can enter the nominal expected voltage to create a simulated power study. For accurate power and energy studies it is required to monitor both voltage and current but this simplified method is useful in certain circumstances.

     

    Easy to use

    The four current probes are connected separately; the instrument automatically detects and scales the probes. The thin current probes are designed to easily get through tight conductor spacing and are easily set to 150 or 1500 A for high accuracy in nearly any application. An innovative tangle-free flat voltage lead makes connection simple and reliable and the instrument’s intelligent ‘Verify Connection’ feature automatically checks to make sure the instrument is connected correctly and can digitally correct common connection issues without having to disconnect measurement resolutionIntrinsic accuracyVoltage1000V0.1 V± (0.2 % + 0.01 %)Frequency42.5 Hz to 69 Hz0.01 Hz± (0.1 %)Aux input± 10 V dc0.1 mV± (0.2 % + 0.02 %)Voltage min/max1000 V0.1 V± (1 % + 0.1 %)Current min/maxdefined by accessorydefined by accessory± (5 % + 0.2 %)THD on voltage1000 %0.1%± 0.5THD on current1000 %0.1%± 0.5Electrical specificationsPower supplyVoltage range100 V to 500 V using safety plug input when powering from the measurement circuit
    100 V to 240 V using standard power cord (IEC 60320 C7)Power consumptionMaximum 50 VA (max. 15 VA when powered using IEC 60320 input)Efficiency≥ 68.2 % (in accordance with energy efficiency regulations)Maximum no-load consumption< 0.3 W only when powered using IEC 60320 inputMains power frequency50/60 Hz ± 15 %BatteryLi-ion 3.7 V, 9.25 Wh, customer-replaceableOn-battery runtimeFour hours in standard operating mode, up to 5.5 hours in power saving modeCharging time< 6 hoursData acquisitionResolution16-bit synchronous samplingSampling frequency10.24 kHz at 50/60 Hz, synchronized to mains frequencyInput signal frequency50/60 Hz (42.5 to 69 Hz)Circuit types1-ϕ, 1-ϕ IT, split phase, 3-ϕ delta, 3-ϕ wye, 3-ϕ wye IT, 3-ϕ wye balanced, 3-ϕ Aron/Blondel (2-element delta), 3-ϕ delta open leg, currents only (load studies)Data storageInternal flash memory (not user replaceable)Memory sizeTypical 10 logging sessions of 8 weeks with 1-minute intervals and 500 eventsBasic intervalMeasured parametersVoltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energyAveraging intervalUser selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 minAveraging time min/max valuesVoltage, Current: Full cycle RMS updated every half cycle Aux, Power: 200msDemand Interval (Energy Meter Mode)Measured parametersEnergy (Wh, varh, VAh), PF, maximum demand, cost of energyIntervalUser selectable: 5 min, 10 min, 15 min, 20 min, 30 min, offStandards compliancePowerIEEE 1459InterfacesUSB-AFile transfer via USB flash drive, firmware updates, max. supply current: 120 mAWiFiFile transfer and remote control via direct connection or WiFi infrastructureBluetoothRead auxiliary measurement data from Fluke Connect® 3000 series modules (requires 1734, or 1732 upgrade option)USB-miniData download device to PCVoltage inputsNumber of inputs4 (3 phases and neutral)Maximum input voltage1000 Vrms, CF 1.7Input impedance10 MΩBandwidth42.5 Hz - 3.5 kHzScaling1:1 and variableMeasurement category1000 V CAT III/600 V CAT IVCurrent InputsNumber of inputs3, mode selected automatically for attached sensorInput voltageClamp input: 500 mVrms/50 mVrms; CF 2.8Rogowski coil input150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4; all at nominal probe rangeRange1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 12”
    3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 24”
    6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 36”
    40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-ELBandwidth42.5 Hz - 3.5 kHzScaling1:1 and variableAuxiliary inputsNumber of inputs2Input range0 to ± 10 V dc, 1 reading/sScale factorFormat: mx + b (gain and offset) user configurableDisplayed unitsUser configurable (7 characters, for example, °C, psi, or m/s)Wireless connectionNumber of inputs2Supported modulesFluke Connect® 3000 seriesAcquisition1 reading/sEnvironmental SpecificationsOperating temperature-10 °C to +50 °C (14 °F to 122 °F)Storage temperature-20 °C to +60 °C (−4 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F)Operating humidity10 °C to 30 °C (50 °F to 86 °F) max. 95 % RH
    30 °C to 40 °C (86 °F to 104 °F) max. 75 % RH
    40 °C to 50 °C (104 °F to 122 °F) max. 45 % RHOperating altitude2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)Storage altitude12,000 mEnclosureIP50 in accordance with EN60529VibrationMIL-T-28800E, Type 3, Class III, Style BSafetyIEC 61010-1
    IEC Mains Input: Overvoltage Category II, Pollution Degree 2
    Voltage Terminals: Overvoltage Category IV, Pollution Degree 2
    IEC 61010-2-031: CAT IV 600 V/CAT III 1000 VElectromagnetic compatibility (EMC)EN 61326-1: Industrial CISPR 11: Group 1, Class A
    Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
    USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103Temperature coefficient0.1 x accuracy specification/°CGeneral SpecificationsColor LCD display4.3-inch active matrix TFT, 480 pixels x 272 pixels, resistive touch panelDimensionsInstrument: 19.8 cm x 16.7 cm x 5.5 cm (7.8 in x 6.6 in x 2.2 in)
    Power supply: 13.0 cm x 13.0 cm x 4.5 cm (5.1 in x 5.1 in x 1.8 in)
    Instrument with power supply attached: 19.8 cm x 16.7 cm x 9 cm (7.8 in x 6.6 in x 3.5 in)WeightInstrument: 1.1 kg (2.5 lb)
    Power supply: 400 g (0.9 lb)Tamper protectionKensington lock slot

       

    For full Fluke 1732 Electrical Power Logger product specifications, please click here: Fluke 1732

    ***Fluke\'s recall instructions have been followed.


    Please check our Huge Inventory with savings of up to 80% off of retail on Cat5/5e/6 LAN Cable Certifiers and Fiber Optic OTDR\'s, Fusion Splicers, CATV Meters, Fiber Optic Kits, Sources, Meters, Tools, Network Analyzers and much more. Here is a Link to our Test Equipment Store. All of our Test Equipment is backed with a Full Warranty and unbeatable customer support & service. Please don\'t hesitate to contact us for a Quote on Something you don\'t see in our inventory, sometimes we have items that may have not been listed or processed yet.





    Test Equipment Store Offers a wide range of Refurbished Telecom/ Datacom Tools and Test Measurement Equipment. Which includes Fiber Optic Test and Splicing tools, Fusion Splicers, OTDRs, Copper and Fiber Cable Certifiers, CATV Test Equipment, Cable and Antenna Analyzers, Network Analyzers and much more!


    We carry a large inventory of quality refurbished and used test equipment from all the major manufacturers. If you are looking for multiple quantities or if we don\'t have a listing for a particular item that you are looking for. Please contact us as it may be fresh inventory waiting to be listed or we\'ll be glad to find it for you at the best price possible and put up an listing for We Ship World Wide!


    We will attempt to ship your item(s) within 24 hours after payment has been received. To get a real-time shipping quote to your destination, enter your country and zip / postal code information into the shipping calculator and click \"Get Rate\".

    Many countries impose their own customs, duties, tariffs, taxes, etc. on items being shipped from a foreign country. We do not cover those cost\'s and we recommend that you contact your countries customs agency for that information.

    We Offer Multiple Quantity Price & Shipping Discounts, Email Us If You Are Interested In Larger accept credit card payment transactions via the online checkout system! The checkout process is designed so that it communicates with the merchant to confirm that payment has been made and cleared. Other methods of payment are outlined through the online checkout process. Winning buyers must contact us within 3 days after sale close if special payment arrangements are needed.

    • Your payment is expected within 5 days after the sale close. Unpaid sales will be forfeited after 5 days of the sale close and the Item(s) will be relisted for sale.

    • Items will be shipped within 24 hours (1 Business Day) upon receipt of payment from the winning buyer. (Certain orders may take longer for processing due to comprehensive final service inspections)

    • A Shipment Tracking number(s) will be provided to inform Buyers of their expected ETA (Estimated Time of Arrival). Tracking number(s) will be provided the same day as order shipment.

    Thank you

    ALL MAJOR CREDIT CARDS & PayPal ACCEPTED





    Sell Smarter with Kyozou.
    Inventory and Ecommerce Management

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design