Standard Accessories:
All controlled by the electric valve
DC Motor
Automatic thermostatic water supply system
Compensate Wider Dental Unit
Handpiece tubing with standard fittings (3sets)
Three way springe (one for hot ,one for cold)(2sets)
Water suction and saliva ejector (1set)
Powerful suction (HVE) apparatus (1set)
Easy cleaning Integral ceramic spittoon
Built-in Water purified system with bottle
Strong and weak dual-purpose operation light (1set)
Low-tension X-film viewer (1set)
Spirit lock tight Equilibrium Device
Doctor stool (1set)
Suitable for adult and children headrest
Foot pedal (1set)
Gross weight:180Kg
Specifications:
Model: TJ2688 A1
Supply Voltage (110V 60Hz or 220V 50Hz )
Air Pressure (>0.55Mpa)
Water Pressure (0.2Mpa-.04Mpa)
Lowest position of Dental chair (17.32”)
Highest position of Dental chair (33.86”)
Highest smallest angle of Dental Chair ( 5°)
Lowest smallest angle of Dental Chair ( 85°)
Portable Dental TurbineUnit with Air Compressor Suction Triplex Syringe 402A
402A Product Features
Aluminum alloy framebox makes the product stronger.
Built-in stainlesssteel air tank with automatic air circulation.
can be easilytransported with pull-out handle and wheels.
Sniffer gun and ThreeWay Syringe can be started after being removed without stepping on the footcontrol .
Handpiece tube adoptselectronic control technology. When the footswitch stops, the Handpiecewill immediately stop spinning.
Evacuation System andthe Handpiece cannot work at the same time.Single use only
Technical data
Model:BD-402A Portable Dental Unit
Votalge: 110 V/60Hz,
Power:600W
Speed R.P.M:1400r/min
Air Flow:65L/min
Pressure:0.6Mpa
Net Weight:19Kgs
Gross Weight:23Kgs
Noise:40dB
Packing Size: 46*35*50cm
Note: This product isonly suitable for 110V voltage, please do not use 220-240V voltage, as 220-240Vwill cause the machine to burn out.
Standard Accessoiries:
High speed Handpiece Pipe 1 set
Low speed HandpiecePipe 1 set
Three WaySyringe 1set
Oilless Air Compressor1set
Waterbottle 1pc
Suction System1pc
Drain bottle 1pc
Foot Control 1pc
Air tank 1PC
Pull rod1PC
Safety Guidelines
1, Before operating the unit, please read the manual carefully and preserve itfor future reference.
2, Please operate and maintain the unit strictly in accordance with theoperational instructions.
3, The user should read the instructions supplied with the dental unitcarefully.
4, Symbol “Attention” denotes that before using the device, read the operatingmanual carefully and carry out all the instructions to avoid any damage orinjury.
5, Please contact the local agent or the manufacturer if the unit needsrepairs. We will supply a high quality of service and assistance for you.
Warning:
1 The power switch should be turned off when the machine stopped working, thetransformer and solenoid valves will heat to burn if long-term power or no stopthe power.
2. Please drain off the water when the water on 2/3 of Suction bottle, thewater will come to motor if the water is higher than 2/3 on suction bottle, theair motor will leakage of electricity or burn if the water come to air motor.
[NOTE]:Both 4 Hole and 2 Hole are available, we send 4 Hole by default!