Product DescriptionSpecificationRunning Watts4400 wattStarting SystemRecoil StartPeak Watts3400 WattsOil Type10W-30Engine Type4 Stroke,Air Cooling,OHV 25°,Single CylinderRuntime at 25% Load10 HoursFuel TypeGasolineRuntime at 50% Load7 HoursFuel Tank Capacity2 Gallons(7.5L)Volume Level(25% load)72 dBA from 23 feetEngine oil capacity0.15 Gallons(0.55L)Max AC Amperage30AAC Voltage120VNet Weight56 PoundsRated Frequency60HzGenerator Size L*W*H19in * 15.2in * 19inConnections2×120V AC Ports, 1×12V DC Port, 1×30A 120V RV PortPackage Size L*W*H20in * 16in * 20.28inPackage including
1x Inverter Generator
1x User Manual
1x Spark Plug Socket Wrench
1x Oil Funnel
1x Screwdriver
Warm Tips:
- This link is for an open box / new packages.The items are unused and in perfect working condition.
- Packages are shipped from local warehouses in the United States.
- If you have any questions, please feel free to contact us by email and we will be happy to assist you.
Important NoticeCold start
1. Close the air damper.
2. Turn on the switch on the panel.
3. Pull the starter rope firmly. After the generator runs for a few seconds, turn the air damper to ON, and the generator will enter normal operation.Hot start
1. You can skip the step of operating the air damper and pull the starter rope directly in the ON position.
2. If the start distance is too short, close the air damper and pull the starter rope once (the generator will most likely not start at this point). If it starts, open the air damper and run normally. If it does not start, open the air damper and pull the starter rope again to start the generator.ECO Mode
Activated by a switch on the control panel, this mode slightly reduces the generator\'s output power. It is generally recommended for use when power demand is low, offering greater energy efficiency and quieter operation. Note that the energy-saving mode must be engaged after starting in normal mode; attempting to start in energy-saving mode may cause starting difficulties.
1. Do not pull the pull rope to start the machine without refilling oil. Starting the generator without refilling oil can cause permanent damage to the internal engine components.
2. All inverter portable functionally tested in the factory and may contain minimum residual oil or fuel odor, which is a normal phenomenon.3. Please follow the instructions to use, if you have any questions, please contact our customer service!Please note: Before use, be sure to remove the red metal plate located in the lower right corner of the generator’s front panel to prevent interference with normal operation.