Free Userbar - Userbars - User Bar - User Bars
 
Advanced search
Registered users

Username:

Password:

Log me on automatically next visit?

¬ Forgot password
¬ Registration

» Upload Userbar
» Animate Userbar
» Userbars Tutorial
» Userbar Tournaments
» Forum
» Chat Room
» FAQ
» Links

• PC Cheat Codes

>> If you dont know how to design a userbar, then write here a Userbar that you want. >> If you know how to design them help these people and design what they request.




USERBARS.org | Free Forum Userbars

On eBay now
eBay

ETERFANT 7/8'' Portable Patient Monitor Multi-parameter ECG NIBP Spo2 TEMP RESP

ETERFANT 7/8'' Portable Patient Monitor Multi-parameter ECG NIBP Spo2 TEMP RESP
$279.00

Buy Now

7 inch Touch screen Multi-parameter patient monitor ECG/RESP/TEMP/NIBP/SPO2/PR M7Features:
1.7 inch screen with true color, wide viewing angle, high brightness LCD display.
2.Simple and friendly operating display interface.
3.Internal chargeable large capacity battery provides convenience for patients\' moving.
4.Playback and browse function for long term waveform and monitor data record.
5.Auto double alarm with audible and visible signals.
6.Anti-defibrillation, anti-interference from high frequency electric knife.

Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR

Technique Specifications:
ECG
1.Lead Menuuration: Five lead ( I, II, III, aVR, aVL, aVF, V)
2.Gain: *0.25,0.5,1,2, automatic. Gain change per min was less than 0.66% / min, The total change in gain within 1h was less than ± 10%.
3.Heart rate: measuring range:
①15 to 300 bpm for adults (beat / min)
②Newborn / child 15-350 bpm (beat / min)
③Accuracy: ± 1% or ± 1 bpm, take the large one
4.Heart rate alarm range:
①Upper limit (adult): 17-300 bpm
②Upper limit (neonate / child): 17 to 350 bpm
③Lower limit (adult): 15 ~ 298 bpm
④Lower limit (newborn / child): 15-348 bpm
⑤Resolution: 1 bpm
⑥Alarm limit error: ± 1% or ± 1 bpm, if large
5.ST segment detection and measurement
①Measuring range: -2.0 mV ~ + 2.0 mV
②Measurement accuracy: the measurement error between-0.02

RESP
1.Measurement method: RA-LL impedance method
2.Detection range of respiratory impedance: 0.3~3Ω
3.Baseline impedance range: 200~4000Ω
4.Tape width: 0.1~2.5Hz
5.Respiratory rate range: From 0 to 120 BrPM in adults
6.Children and newborns ranged from 0 to 150 BrPM
7.The measurement error shall be ± 2 BrPM within 7 BrPM to 120 BrPM.

SpO2
1.Measuring range: 0~100%
2.Resolution ratio: 1%
3.Accuracy: Within the range of 70% to 100%, the measurement error
shall be ± 2%; Measurement error is not defined from 0% to 69%

PR
1.measuring range: 25~250bpm
2.Resolution ratio: 1bpm
3.Accuracy: ±3bpm
4Refresh time: 1s

TEMP
1.Applicable temperature sensor: Body chamber probe / body temperature probe
2.Number of channels: 2 channel
3.Measuring range: 0~50℃
(The maximum allowable error of a complete thermometer is ±
0.2℃ from 25℃ to 45℃)
4.Resolution ratio: 0.1℃
5.Alarm accuracy: *0.1℃ (without probe error)

NIBP
1.Measurement method: Pulse wave oscillation
2.Work pattern: Manual / automatic
3.The measurement interval of the automatic measurement min
4.Measurement time of the continuous: 5 Minutes
5.Measuring range
5.1Adult
① SYS: 40~270mmHg
② DIA: 10~210mmHg
③ MEAN: 20~230mmHg
5.2Children
① SYS: 40~200mmHg
② DIA: 10~150mmHg
③ MEAN: 20~165mmHg
5.3Neonatus
① SYS: 40~135mmHg
② DIA: 10~95mmHg
③ MEAN: 20~110mmHg
6.Static pressure Measuring range: 0~300mmHg (0-40kPa)
7.Static pressure precision: />
PM80D
Features:
1.Unique accessory management cabinet
2.8 inch high resolution color TFT display
3.USB interfaces support easy software upgrade and data transfer
4.Three Working Modes: Monitoring, Surgery and Diagnosis.
5.Simple and friendly operating display interface.
6.Multi-display modes suitable for different applications:
Standard Interface, Large font, ECG Standard Full Display, OXY , Trend Table, BP Trend.
7.Built-in high capacity battery up to 3 hours of continuous work

Standard Parameters:
ECG, RESP, TEMP, NIBP, SPO2, PR

Technique Specification:
ECG
1.Lead Mode: 5 Leads (I, II, III, AVR, AVL,AVF, V)
2.Gain: 2.5mm/mV, 5.0mm/mV, 10mm/mV, 20mm/mV
3.Heart Rate: 15-300 BPM (Adult); 15-350 BPM (Neonatal)
① Resolution: 1 BPM
② Accuracy: ±1%
③ Sensitivity >200 uV(Peak to peak)
4.ST measurement range: -2.0 ~ +2.0 mV
① Accuracy: -0.8mV~+0.8mV: ±0.02mV or ±10%, which is greater
Other Range: unspecified
5.Sweep speed: 12.5 mm/s, 25mm/s, 50mm/s
6.Bandwidth:
7.Diagnostic: 0.05~130 Hz
8.Monitor: 0.5~40 Hz
9.Surgery: 1~20 Hz

SPO2
1.Measuring Range: 0 ~ 100 %
2.Resolution: 1%
3.Accuracy: 70% ~ 100% (±2 %)
4.Pulse Rate: 20-250 BPM
5.Resolution: 1 BPM
6.Accuracy: 3 BPM

NIBP
1.Method: Oscillometry
2.Measure mode: Manual, Auto, STAT
3.Unit: mmHg, kPa
4.Measure and alarm range:
5.1 Adult Mode
① SYS 40 ~ 280 mmHg
② DIA 10 ~ 225 mmHg
③ MEAN 20 ~ 240 mmHg
5.2 Pediatric Mode
① SYS 40 ~ 220 mmHg
② DIA 10 ~ 160 mmHg
③ MEAN 20 ~ 170 mmHg
5.3 Neonatal Mode
① SYS 40 ~ 135 mmHg
② DIA 10 ~ 100 mmHg
③ MEAN 20 ~ 110 mmHg
6.Resolution: 1mmHg
7.Accuracy: 5mmHg

RESP
1.Method: Impedance between RA-LL or RALA
2.Measurement Range:
① Adult: 10 ~ 120 BrPM
② Neonatal / Pediatric: 7 ~ 150 BrPM
3.Resolution: 1 BrPM
4.Accuracy: 2 BrPM

TEMP
1.Measure and Alarm Range: 0 ~ 50℃
2.Resolution: 0.1℃
3.Accuracy: 0.1℃

Standard Configuration:
Main Unit *1
5-lead ECG cable *1
Disposable ECG Electrode *5
Adult Spo2 probe *1
Adult NIBP cuff *1
NIBP extension tube *1
Temperature probe *1
Power Cable *1
User Manual *1FDAStatement:
Thanksforyourunderstanding!

Buy Now

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.


Related Userbars
       

More items on eBay

As an eBay Partner, userbars.org may earn a commission from qualifying purchases.



All userbars are property of respective authors.
Copyright © 2002 4homepages.de | Template © 2005 Bali Web Design