Multi-function Relay Control Module, designed for users with many different needs, adopts microcontroller as the main control unit, with 32 functions preset, users can use the corresponding specific functions according to the actual needs. Features
1. Newly upgraded, the module function is increased to 32 kinds to meet more application requirements.
2. Power supply anti-reverse connection function, will not damage the module because of the wrong power supply.
3. Timing accuracy up to 0.01 sec. 0.1 sec.(min.) ~999 min.(max.) selectable.
4. Low power consumption and power saving settings, can close the display area.
5. Can be applied to water pump control, motor control, lighting control, solenoid valve control and so on. Specification
Name: Multi-function time-delay relay
Relay voltage number: DC5V/12V/24V optional
Input voltage: 5V version: DC5V power supply; 12V version: DC12V power supply; 24V version: DC24V power supply.
Output Load: DC 30V, max. 10A; AC 250V, max. 5A; Trigger Signal: 5V version (high level: 5V); 12V version (high level: 120), 24V version (high level: 24V) Low level is 0V.
Static current: 20mA
Operating current: 60mA
Operating temperature: -25°C to 85°C
Power failure memory: Yes Instructions for use:
Working parameter setting instructions.
Press and hold the K1 key, the display will show P-xx after 2 seconds, press K2 and K3 to change the working mode. After selecting a good working mode, short press K1 key to enter the A time setting, the screen shows Axxx, at this time, press K2 and K3 key to modify the A time parameters, k2 and K3 key short press plus or minus 1, long press fast plus or minus 10, press K4 key can be set to set the position of the decimal point. After setting A time, then press K1 key for B time setting, the screen displays bxxx, at this time, press K2 and K3 key to modify B time parameter, k2 and K3 key short press plus or minus 1, long press fast plus or minus 10, press K4 key to set the position of decimal point. After setting B time, (if the mode has c cycle times parameter) press K1 again for c cycle times setting, the screen displays Cxxx, at this time, press K2 and K3 to modify the c cycle times parameter, K2 and K3 key short press plus or minus 1, long press fast plus or minus 10. after setting is completed, press K1 key for the last time to exit the setting state and save all the parameters. The position of the decimal point and the time unit it represents are described in the table below.
X.XX Decimal point in hundredth position, time range 0.01~9.99 sec.
XX.X Decimal point in the tens place, time range 0.1~99.9 sec.
XXX without decimal point, time range 1~999 seconds
XXX. Decimal point in single digit, time range 1~999 minutes
Turn off the display: in non-setting state, press K4 to turn off the display, press again to turn it on again. Operating modes (32 types).
P-11: Tap mode, with a signal suction, no signal disconnection.
P-12: self-locking mode, each time after triggering, the relay state is flipped once.
P-13︰After triggering, the relay will be activated and disconnected after delay time A; the trigger is invalid during the delay period.
P-14︰After triggering, the relay is activated and disconnected after time delay A; the trigger is re-timed during the delay period.
P-15︰ After triggering, the relay is engaged and disconnected after delay A time; the trigger is cumulative timed during the delay period.
P-16︰ After triggering, the relay will be activated and disconnected after delay A time; trigger reset (relay disconnected) during the delay period.
P-17︰After triggering, the relay will be engaged during the signal duration, the input signal will disappear, and the relay will be disconnected after A time delay; the relay will be triggered again during the delay period to remain engaged and the timing will be stopped until the last signal disappears, and the relay will be disconnected after A time delay.
P-18: Immediately after energizing, the relay will absorb, and disconnect after delay time A seconds; until the next energizing.
P-21︰Give a signal, the relay will be absorbed after A time delay.
P-22︰Give a continuous signal, after A time delay, the relay will be activated; when the signal disappears, the relay will be disconnected.
P-23︰The signal disappears more than A time, the relay is absorbed; there is a signal, the relay is disconnected.
P-24︰Give continuous signal, after exceeding A time, the relay is absorbed; the signal disappears more than A time, the relay is disconnected.
P-25: give a continuous signal, more than A time, the relay is engaged; again give a continuous signal, more than A time, the relay is disconnected
P-26: give the signal, the relay is closed after A time; after the signal disappears, the relay is closed again after A second.
P-27: With pulse signal (rising edge or falling edge) the relay breaks, without pulse signal, the relay absorbs after delay A time (continuous high level or continuous low level are considered as no pulse).
P-28: After power-on, the relay will be closed after delay time A until power-off.
P-31: After power-on, relay is absorbed for A time and disconnected for B time, infinite cycle; power-off stops.
P-32: With a continuous signal, the relay is absorbed for A time, disconnected for B time, infinite cycle; the signal disappears and the cycle is terminated.
P-33∶Give a signal, the relay will be engaged for A time, disconnected for B time, infinite cycle; give a signal again, terminate the cycle.
P-34: After power on, after delay time A, the relay will absorb, and after absorb time B, it will disconnect.
P-35: Give a signal once, after delaying A time, the relay is absorbed, and disconnected after absorbing B time.
P-36︰Give a continuous signal, after exceeding A time, the relay will absorb, and disconnect after absorbing B time; the signal disappears, the timing is cleared to zero, and the relay is disconnected.
P-37: With signal, the relay will automatically disconnect after A time, and then time B after disconnecting, the signal trigger is invalid in A+B time.
P-38︰With signal, the relay will automatically disconnect after A time of absorption, after disconnecting and then timing B time, and then automatically disconnect after A time of absorption again.
P-41︰With signal, no action; signal disappears and trigger; relay absorbs and disconnects after delayed A time.
P-42︰Signal disappeared, relay absorbed after time delay A; relay disconnected after time delay B again.
P-43︰Signal disappears, the relay is activated beyond A time; then the relay is disconnected after B time delay.
P-44 : After power on, the relay will be engaged for A time and disconnected for B time; the relay will be disconnected and stopped after cycling for c times.
P-45 : No action after power-on; after giving signal, the relay is absorbed for A time and disconnected for B time; after cycling c times, the relay is disconnected and stopped; if a signal is given, it is executed again.
P-46 : After giving signal for more than A times, the relay is absorbed; keep absorbed; power-off stops. Package includes