Crookes Tube/Cathode Ray Tube Demonstrator/Kathoden Ray Tube Lab Equipment--
$123.49

Crookes Tube/Cathode Ray Tube Demonstrator/Kathoden Ray Tube Lab Equipment--
There are four sets of cathode ray tubes produced by our factory, namely J2453 type magnetic effect cathode ray tube, J2454 type direct cathode ray tube, J2455 type mechanical effect cathode ray tube and J2456 type electrostatic effect cathode ray tube, which are used for physics teachers to demonstrate experiments. In order to facilitate the correct use of this set of instruments, the instructions are as follows:
-, use
1. Magnetic effect cathode ray tube: demonstrates the phenomenon of deflection of cathode rays in a magnetic field, indicating that cathode rays are a stream of charged particles emitted from the cathode. 2, direct into the cathode ray tube: demonstrate that the cathode ray moves in a straight line and can be blocked by metal. 3, showing the mechanical effect of the cathode ray tube: demonstrates the phenomenon of the mechanical movement of the cathode ray, indicating that the cathode ray has momentum and energy. 4, electrostatic effect cathode ray tube: demonstration of the phenomenon of cathode rays deflecting in the electric field, proving that cathode rays are negatively charged particle flow (that is, electron flow)
structure
A direct human magnetic effect cathode-ray tube consists of a bubble shell, a baffle, and fluorescence
Cathode, anode, bakelite base, etc. The cathode ray tube is made of bubble shell, metal baffle: support, cathode, anode, glue base, etc. 3. The mechanical effect cathode-ray tube is composed of a bubble shell, a guide rail support, a small wheel, a circular electrode, a rubber base, etc. 4, electrostatic effect cathode ray tube is composed of bubble shell, baffle, light plate, electric field electrode, cathode, anode, bakelite base and so on.
Supporting instrument
Low voltage DC power supply: Output 10-12V DC.
High pressure induction ring: spark distance 50-80mm.
Voltage regulator: AC 220V+10V.
Dc High voltage current: Output DC 250V-300V.
Shoe magnet: Opening 50-70mm.
Wires and wires with alligator clips.
Demonstrate environmental conditions m
The relative humidity is not more than 80%. Temperature -10 °C -40°CFour kinds of cathode ray tube wiring methods are shown in Figure 1 to Figure 4. Several kinds of cathode-ray tubes have the A1 and A2 poles of emitting rays. A is connected to the induction cabinet output \"+\" pole, and A is connected to the induction ring output \"_\" pole. When the power supply is switched on, there are cathode rays emitted from the cathode A, such as anti-A1, A2, do not emit obvious rays (indicating mechanical effect, can be changed induction ring switch. (except for the tube),
1, magnetic effect cathode-ray tube in the demonstration, A2 emission cathode emitter on the fluorescent plate shows a band track, indicating that the cathode ray is moving in a straight line. Then add a transverse magnetic field in the middle (with a horseshoe magnet opening down, cross stuck in the middle of the tube to form a magnetic field), the cathode ray track will be deflected, so
The ray is determined to be a stream of charged particles. Note: The ray emitted by the cathode A2 is the electron stream, which is opposite to the direction of the current usually specified, and the direction of the ray deflection can be judged according to the direction of the magnetic field. 2, the direct cathode ray tube demonstration is best performed in a dark room. In the demonstration A, the cathode ray is emitted, and a shadow of the same shape as the metal baffle will appear on the glass wall of the screen at the large end of the ray tube. The glass around the shadow shows a bright yellow-green fluorescence. This shows that the cathode rays are moving in a straight line and their ability to penetrate the metal sheet is very weak.3, the mechanical effect of the cathode ray tube in the demonstration, the field electrode emits cathode rays, projected on the fluorescent material coated on the wing, the side of the wing illuminated by the cathode rays will emit fluorescence, and the small wing wheels roll along the direction of the cathode ray movement. By turning the switch on the induction ring, the direction of motion of the cathode ray is changed (both circular electrodes can emit cathode ray), and the direction of movement of the wing wheel is also changed. This means that a cathode ray is a stream of particles that have a certain momentum and energy and can transfer it to the object being irradiated.
4, electrostatic effect cathode-ray tube in the demonstration, first turn on the low power supply and rotate the induction ring of the conversion switch, so that it produces cathode rays, the fluorescent plate will appear on a strip track. Then the DC high-voltage current is switched on to form an electric field. At this time, when the cathode ray passes through the fluorescent plate, the ribbon track will be deflected to the direction of the electrode plate with high potential. With the change of the output voltage of the regulator transformer (that is, the change of DC Gaulle)
The deflection Angle of the strip track also changes. According to the deflection of the cathode ray in the electric field, it is certain that the cathode ray is a stream of particles that help charge, and this negatively charged particle is the electron.
Note: The higher the DC component added to the B1 and B2 electric field electrodes, the more stable the polar ray band track deflection. On the contrary, the banded track will flash and be unstable. The DC voltage should not be added too high (not more than 400V) to avoid \"ignition\" between parallel plate electrodes. If there is no regulating transformer, you can also get the deflection strip track without directly using the DC high-voltage power supply, just to see the change of the deflection Angle.Practice shows that without voltage regulating transformer and DC high voltage power supply, one electrode of B1 and B2 is grounded and the other electrode is empty, and the banded track deflection of cathode rays is particularly obvious by using self-raising voltage to produce electrostatic field.
Six, precautions
1, vacuum glass products, gently handle, pay attention to protect the bubble shell, to prevent gas failure.
2.Do not exert too much force when connecting electrodes, so as not to damage the instrument.
3, pay attention to wiring according to the wiring diagram, proofread the power supply voltage, check the error can be demonstrated.
4, do not apply the voltage to the tube for a long time to emit the cathode line, so as to avoid the glass being irradiated by the cathode ray for a long time and strongly absorb the gas, emit light, and avoid accelerating the aging of the fluorescent plate.
5, the instrument should be placed flat, safe, stored in a cool ventilated dry place moisture and shock proof.Packing contents: 1 pieceWarm reminder:
1. Your valid phone number is required, otherwise we cannot guarantee the safe arrival of the package.
2. The price and freight of the goods do not include import duties and other charges, which shall be paid by the buyer. Buyers should know in advance the tariffs required by the receiving country before purchasing.
3. Some countries need to provide the recipient\'s tax ID, such as South Africa, Chile, Peru, Mexico, South Korea and other countries.
4. After receiving the package, if there is any problem with the product, please contact us by leaving a message on first. We\'ll get you sorted out. Please do not leave negative or neutral response without first contacting us. A satisfactory transaction for both buyer and seller is our goal.

When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.