Contact Add to Cart Fully Refurbished Carl Zeiss Atlas 9000 Topographer with Keyboard and Windows XP Categories Have a question?
1-877-924-2020 This Zeiss Topographer has been completely tested and serviced by our highly skilled and trained in-house technicians. We perform a very thorough inspection of the device at the board level to ensure the system is operating to precise manufacturer specification. This unit is in excellent mechanical and cosmetic condition!
This model is ideal if you are looking for a low cost topographer. If you require Windows 10, please view our other options.
**Table NOT included but available for an additional charge
Key Features:
By merging proven ATLAS Placido disk technology with Visante OCT pachymetry, Visante Omni now provides comprehensive anterior and posterior topography.
Proven Placido Disk Technology with patented Cone-of-Focus Alignment System.
SmartCapture Image Analysis Technology analyzes multiple images during alignment and automatically selects the highest quality image.
MasterFit™ II Contact Lens Software helps streamline the fitting of gas permeable (GP) lenses and guides you through difficult and specialty fits.
Data compatibility with previous generation ATLAS Corneal Topography Systems to facilitate data management and patient follow up.
SmartCapture analyzes 15 digital images per second during alignment and automatically selects the highest quality image.
Next generation image processing provides more repeatable, reliable results, even in difficult cases.
Less dependence on operator technique means greater efficiency and fewer repeat exams.
Corneal Wavefront Analysis takes corneal topography to a new dimension.
Using ray tracing technology, the ATLAS displays higher-order corneal aberrations, providing valuable insight for patient education and treatment planning.
Educate patients about higher-order aberrations and simulate visual acuity.
Assess corneal refraction with image simulation and point spread function.
Measure corneal spherical aberration with Zernike analysis to optimize the selection of aspheric IOLs.
View the effects of individual higher order corneal aberrations.
View changes in contrast sensitivity through the modulation transfer function (MTF).
Pupil size, measured at two levels of illumination (scotopic and photopic @700 nm), provides insight into optical zone under varying light conditions.
View centration of LASIK or orthokeratology treatment in relation to pupil center to assess treatment effectiveness.
Improve multi-focal contact lenses selection by understanding patient\'s pupil size at two levels of illumination.
Streamline contact lens selection and fitting with automatic Horizontal Visible Iris Diameter (HVID) meCompact, integrated system with powerful computer and analysis software.
Unique chin rest positions patient for easy image capture and wide peripheral coverage and automatically detects OD/OS.
Non-visible Placido ring illumination is comfortable for even the most light-sensitive patients.
Working Distance: 70 mm
Field of View: 17 mm X 14.5 mm
Placido Rings: 22 (18 superiorly, 22 inferiorly)
Illumination Source: Non-visible infrared (950 nm) LED
Optics: Digital CMOS camera with 1280x1024 pixel Range: 15 to 95 D (3.5 to 22.5 mm)
Accuracy: ± 0.05 D (± 0.01 mm)Reproducibility: ± 0.10 D (± 0.02 mm) HVID (white to white):
- Measurement Range: 10.0 to 14.0 mm
- Resolution: 0.1 Images: Scotopic and photopic (700 nm)
- Measurement Range: 0.5 to 11.0 mm
- Resolution: 0.1 mm
Views:
- Axial Curvature
- Tangential Curvature
- Elevation (Best-Fit Sphere)
- Irregularity (Best-Fit Ellipsoid)
- Videokeratoscopic (Rings, Scotopic, Power
- Mean Curvature
- Corneal Wavefront
- Image Simulation
- Point Spread Function (PSF)
- Modulation Transfer Function (MTF)
Presentation Displays:
- Single View
- Overview
- OD/OS with L x 37 W x 50 H (cm)
- 39 lbs. (17.7 kg)
Electrical: 100-240V~: 50/60Hz, 2-1A
Additional photos are available upon request.
Financing available; call 1-877-924-2020
WORLDWIDE SHIPPING AVAILABLE
We ship globally and have successfully served customers in over 100 countries. Contact us for an international shipping quote at 1-877-924-2020.
Laser Locators is a full-service sales and service provider, not a broker. Every system is hand-selected, inspected, and thoroughly tested by our technicians and engineers to ensure excellent cosmetic appearance and reliable performance.
Buy with confidence from Laser Locators.
OUR STORY Founded in 2004 and headquartered in Tampa, Florida, USA, Laser Locators is a trusted global provider of ophthalmic equipment, specializing in refurbished and new surgical and refractive lasers, as well as diagnostic and surgical systems.
All refurbishment, testing, service, and quality control are performed by our experienced engineers and technicians at our Laser Performance Center, located within our 12,000-square-foot, state-of-the-art facility, as well as in the field when needed. Every system we sell is fully inspected, supported, and backed by warranty, so you can purchase with confidence.
Buyers are welcome to visit our facility prior to purchase. Call 1-877-924-2020 to schedule a tour, virtual or in person.
Disclaimer
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, do not offer on this item unless you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item. If you have questions about legal obligations regarding sales of medical devices, you should consult with the FDA\'s Center for Devices and Radiological Health: Click Here
When you click on links to various merchants on this site and make a purchase, this can result in this site earning a commission. Affiliate programs and affiliations include, but are not limited to, the eBay Partner Network.