OVERVIEW
Autocall A4099-9006 (Simplex 4099-9006) addressable dual-action manual fire alarm pull station with LED status indicator. Autocall and Simplex are both Johnson Controls brands and these parts are functionally identical across the two labels.
Dual action means two deliberate motions are required to signal alarm: first push the spring-loaded interference plate marked PUSH, then pull the handle down firmly. This two-step design deters accidental and nuisance activation. An integral individual addressable module (IAM) reports station status continuously to the fire alarm control panel over a single pair of IDNet or MAPNET II wires.
ABOUT THE KEY: no key is included, and none is supposed to be. Simplex and Autocall manual stations are supplied without keys because the reset lock is keyed the same as the fire alarm cabinets on the job, so installers already carry the B key. The B key is a separately ordered item. Nothing is missing from this package.
TESTED & WORKING STATUS
Not tested. Surplus installer stock that has not been bench powered, addressed, or commissioned. No functional claim is made about the alarm switch, the LED, IDNet or MAPNET II communication, or DIP addressing. Verification was limited to reading the printed factory PID label on the carton and the labels on the station and backplate, and to visual inspection of the mechanism and Addressable manual fire alarm station, dual action push then pull
Protocol: IDNet or MAPNET II signaling line circuit; power and data on a single wire pairAddressing: Eight-position DIP switch under a resealable labelIndicator: LED flashes during normal communication and goes steady when the station is activatedHousing: Lexan polycarbonate, red, 5 in. H x 3-3/4 in. W x 1 in. DMounting: Single-gang or 4 in. square electrical box, semi-flush or surface; box not includedWire connections: Screw terminals for in and out wiring, 18 AWG to 14 AWGEnvironment: Indoor, 32 to 120 degrees F; NEMA 1 rated with an appropriate back boxListings: UL Listed to Standard 38 for manual fire alarm boxes, FM Approved 519-008 FADA compliant when installed at the height specified by NFPA 72Break-rod: Internal plastic break-rod fitted, optional in use, replaceable via 2099-9804Part number: 06501211ACDate code: 22 025Country of manufacture: MexicoLabel references: 0623-1765AC Rev B addressable manual station, 0623-1766 Rev A non-coded alarm box 596B, 0623-1704AC Rev BCONDITION
Carton opened for inspection; all contents present. The red Lexan housing is free of cracks, chips, scuffs, and discoloration. The pull lever is in the normal unlatched position and the internal break-rod is intact and unbroken. The galvanized backplate is clean with its factory wiring harness and terminal block undisturbed and the FACTORY WIRING label intact. Key cylinder is present in the housing. No mounting-screw witness marks, no field wiring residue, no dust accumulation, and no paint or drywall overspray. Carton exterior shows light shelf and handling wear consistent with warehouse storage.
COMPATIBILITY
- IDNet panels including Simplex 4007ES, 4010, 4010ES, 4100ES, and 4100U
- MAPNET II panels including Simplex 4100, 4120, and 4020, and 2120 Communicating Device Transponders
- Autocall control units using the equivalent IDNet architecture
- Cross-references directly to Simplex 4099-9006
- Can be used to replace 4099-9003 in legacy applications
- Compatible back boxes ordered separately include 2975-9178 surface mount steel box in red and 2975-9022 cast aluminum surface mount box in red
- Replacement break-rod 2099-9804, sold in packs of five
- B key required for reset and testing, ordered separately
WHAT'S INCLUDED
- 1x A4099-9006 addressable dual-action manual pull station
- Galvanized backplate with factory-wired terminal block
- Printed installation instruction sheet
- Factory hardware pack with mounting screws
- Original carton
- NO key, which is correct for this product and not an omission. NO electrical box or back box.
INSTALLATION & LIABILITY
This device is part of a life-safety system and must be installed, programmed, and commissioned by a licensed fire alarm professional in accordance with NFPA 72 and all applicable local codes. Nothing in this listing is certified working; no bench power-up has been performed, and a bench power-up would not constitute commissioning in any case. Some new items in this inventory have been opened for inspection and identification. Buyers must verify part number, revision, firmware, and panel compatibility against their own system before purchase, and must supply their own B key and back box. No manufacturer warranty transfers with this sale.